Number of Channels:
Output Capacity:
Input Power:
Dimmer control system:
Load Filtering:
Control Input Types:
Output Panels:
Cooling System:
Dimensions:
Weight:
Recommended Ambient
Operating Temperature:
Short-Circuit
Current Rating:
Load Type:
Enclosure Type:
NSI DS8/DS12 MODULAR DIGITAL DIMMING SYSTEM
Software Revision 1.1x, 8/24/99
NSI
DS8/DS12 DIMMER PACKS
Version 1.1x Software
Part Number LIT-31665-0 Rev B – 9/25/2000
Model DS8-12
: 8 channels
Model DS12-12
: 12 channels
Model DS8-24
: 8 channels
Model DS12-24
: 12 channels
Model DS8-12
: 1200 Watts per channel @ 120VAC
Model DS12-12
: 1200 Watts per channel @ 120VAC
Model DS8-24
: 2400 Watts per channel @ 120VAC
Model DS12-24
: 2400 Watts per channel @ 120VAC
Model DS8-12
: 1 phase, 3 wire, 120/240 VAC, 40 Amps, 47 – 63Hz
Model DS12-12
: 1 phase, 3 wire, 120/240 VAC, 60 Amps, 47 – 63Hz or
3 phase, 4 wire, 120/208 VAC, 40 Amps, 47 – 63Hz
Model DS8-24
: 1 phase, 3 wire, 120/240 VAC, 80 Amps, 47 – 63Hz
Model DS12-24
: 1 phase, 3 wire, 120/240 VAC, 125 Amps, 47 – 63Hz or
3 phase, 4 wire, 120/208 VAC, 80 Amps, 47 – 63Hz
Microprocessor digital phase control.
350 s
12 channels of 0 -10VDC [ 15 pin Male D-Sub on back of pack ]
Pins 1 through 12 = Channels 1 through 12, pin 13 = T/C,
Pin 14 = +14.4VDC, Pin 15 = Analog COM
MICROPLEX (in / through) on 3 pin XLR connector
DMX-512 (in / through) on 5 pin XLR connector
Luma-Net - 6 pin Terminal Block
Class 2 low voltage
PB8/12 – 1 - NEMA 5-15 or 5-20 receptacle per channel or,
SP8/12 – 1- 20 Amp stage pin receptacle per channel or,
KO8/12 – hard-wired terminal blocks.
Thermostatically controlled and monitored fan forced air with individual dimmer module
temperature monitoring. Fan exhaust on right rear side.
3.5"High x 17.2" Wide x 17.0"Deep. ( 2 EIA 19" Rack Spaces)
50lbs
0-25 degrees C ( 32 - 85 degrees F)
10,000A RMS Sym. @ 240VAC
AC lighting loads only
For indoor use only
Utilizer dans un endroit a l'abri
Copyright 1999, NSI Corp.
Specifications subject to change without notice
Need help?
Do you have a question about the DS12 and is the answer not in the manual?
Questions and answers
can I use an led in place of a par 38 in the ds-12 dimmer system
The NSI DS12 dimmer system is designed to control lighting loads rated for 115/120V and within the dimmer's wattage and ampacity limits. While the documents do not specifically mention compatibility with LED bulbs, using an LED in place of a PAR 38 bulb depends on the type of LED and whether it is dimmable and compatible with the dimming method used (e.g., phase-control dimming). Standard dimmer packs like the DS12 may not work properly with all LED bulbs, especially non-dimmable ones or those incompatible with traditional dimming systems.
Therefore, LED bulbs must be dimmable and confirmed compatible with the dimmer type used in the DS12 system.
This answer is automatically generated