Download Print this page
Leviton AC00R-10 Installation Instructions

Leviton AC00R-10 Installation Instructions

3-way or more applications (multi-location) dimmer and switch remotes

Advertisement

Quick Links

PK-93620-10-00-0A-X1
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-
operated appliance.
• For Hi-lume
®
or Eco-10™ (EcoSeries) electronic ballast applications, use instruction sheet that comes with the dimmer for multi-location applications.
• Acenti™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Acenti™ remotes for multi-location dimming.
Tools needed to install your Remote:
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
INSTALLING YOUR REMOTE
NOTE: Use check boxes
when Steps are completed.
WARNING:
TO AVOID FIRE, SHOCK, OR DEATH;
Step 1
TURN OFF POWER at circuit breaker or fuse and test
that power is off before wiring!
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Identifying your wiring application (most
Step 2
common):
NOTE: If the wiring in the wall box does not resemble
any of these configurations, consult a qualified electrician.
2
1
3
1
2
3
4
4
5
5
6
3-Way
4-Way
1. Line or Load (See important
1. First Traveler – note color
instruction below)
2. Second Traveler – tagged
2. Neutral
3. Neutral
3. Ground
4. Ground
4. First Traveler – note color
5. Third Traveler – note color
5. Second Traveler – note color
6. Fourth Traveler – tagged
NOTE: For matching remote w/LEDs
NOTE: For matching remote
installation, the First Traveler becomes
w/LEDs installation, the First
Line Hot.
Traveler becomes Line Hot.
IMPORTANT:
For 3-Way applications, note that one of the screw terminals from
the old switch being removed will usually be a different color
(Black) or labeled Common. Tag that wire with electrical tape and
identify as the common (Line or Load) in both the dimmer wall box
and remote wall box.
For 4-Way applications, note that the old switch being removed
will have 4 screws plus a ground screw. Tag the two same color
insulated wires with electrical tape.
Preparing and connecting wires:
Step 3
This remote can be wired using side wire terminal
screws or through backwire openings. Choose
appropriate wire stripping specifications accordingly.
Cut
(if necessary)
Cat. No. ACØØR-10, Coordinating Dimmer Remote (no LED's)
Cat. No. ACØØR-1L, Matching Dimmer Remote (with LED's)
Cat. No. ACØSR-10, Coordinating Switch Remote (no LED's)
Step 3 cont'd
Strip Gage (measure
bare wire here or use
gage on back of the
5/8"
dimmer)
(1.6 cm)
Side Wire Connection
Side wire terminals accept
#14 AWG solid copper wire only.
Strip Gage (measure
bare wire here or use
gage on back of the
5/8"
dimmer)
(1.6 cm)
Back Wire (either hole may
be used)
Back wire openings use #14-12
AWG solid copper wire only.
• Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
• Remove insulation from each wire in the wall box as shown.
Installing your Alignment Plate:
Step 4
Important Notice for Installer
To achieve proper aesthetic installation of the Acenti
products, the wall surface surrounding the wall box opening
must be fairly flat and free of irregularities. The wall box must
be level and recessed or flush to the wall surface. The Acenti
installation system allows for adjustments that will correct
minor flaws that may be present in the installation area.
This device must be installed with the Acenti™ Alignment
Plate. The Alignment Plate is packaged with the Acenti™
Wallplate, which is sold separately from this device.
The Alignment Plate will function properly only if it is
mounted to a flat wall surface as described above.
• Leviton recommends to temporarily position the Alignment
Plate prior to wiring the device. If the wall box wires
extend at least 6 inches out of the wall box, it is also
possible to install the Alignment Plate after the device has
been wired (refer to Wallplate instruction sheet).
• The Alignment Plate must be installed with the tab
towards the bottom.
• Leviton recommends the following 3 methods to
temporarily hold the Alignment Plate – use of device
mounting screw, use of wall box wires, or use of electrical
tape (refer to the following figures):
Alignment Plate Held
Alignment Plate
Alignment Plate
By Mounting Screw
Held By Wires
Held By Tape
Electrical
Tape
Mounting
Screw
Alignment
Plate
3-Way or More Applications (Multi-location)
Dimmer and Switch Remotes
Cat. No. ACØSR-1L, Matching Switch Remote (with LED's)
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
• Use only one (1) dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will turn the
light on at the brightness level selected at the dimmer.
• Recommended minimum wall box depth is 2-1/2".
• Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Step 4 cont'd
• For Incandescent and Magnetic Low-Voltage Applications, go
to appropriate Steps 5a-5d.
• For Electronic Low-Voltage, Electronic Switch, Mark 10™ and
Fan Speed Applications, go to appropriate Steps 5e-5h.
3-Way Wiring with Coordinating Remote
Step 5a
(no LEDs) Application:
NOTE: Incandescent and Magnetic Low-Voltage
installations only. NOTE: Screw terminal dimmer depicted.
Dimmer
Coordinating Remote
Terminal
1
1
2
Screw marked
2
Black (BL)
3
3
4
Terminal
4
Screw marked
Yellow/Red
5
5
(YL/RD)
Terminal
Screw marked
Red (RD)
Coordinating Remote (no LEDs)
Control
not used
WH
Hot (Black)
Black
Green
Green
BL
BL
Ground
Ground
YL/RD
YL/RD
RD
RD
Load
Line
120VAC, 60Hz
White
Neutral (White)
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer can
be installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes cannot
exceed 300 ft.
• Green or bare copper wire in wall box to Green terminal screw or
Green dimmer lead.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch to dimmer terminal screw marked "BL" or Black dimmer lead.
• First Traveler wall box wire to terminal screw marked "RD" or Red
dimmer lead (note wire color). This traveler from the dimmer must go
to the terminal screw on the remote marked "RD".
• Remove Red insulating label from terminal screw marked "YL/RD" or
Yellow /Red dimmer lead.
• Second Traveler wall box wire to terminal screw marked "YL/RD" or
Yellow/Red dimmer lead (note wire color). This traveler from the
dimmer must go to the terminal screw on the remote marked "YL/RD".
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
• Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch to
terminal screw marked "BL".
• First Traveler wall box wire (note color as above) to terminal screw
marked "RD". This traveler from the remote must go to the terminal
screw on the dimmer marked "RD" or Red dimmer lead.
• Second Traveler wall box wire (note color as above) to terminal screw
marked "YL/RD". This traveler from the remote must go to the terminal
screw on the dimmer marked "YL/RD" or Yellow/Red dimmer lead.
• Remote terminal screw marked "WH" should have White insulation
label affixed.
NOTE: If insulating label is not affixed to terminal screw marked "WH",
use electrical tape to cover.
• Proceed to Step 6.
4-Way Wiring with Coordinating Remote
Step 5b
(no LEDs) Application:
NOTE: Incandescent and Magnetic Low-Voltage installations
only. NOTE: Screw terminal dimmer depicted.
Coordinating Remote
Coordinating Remote
Dimmer
(3-Way Wall box from Step 2)
(4-Way Box from Step 2)
(3-Way Wall Box from Step 2)
Terminal
Terminal
Screw marked
Screw marked
Red (RD)
Red (RD)
1
1
2
3
Terminal
Screw marked
Red (RD)
3
3
5
4
1
4
2
5
5
6
Terminal
Terminal
Screw marked
Screw marked
Yellow/Red
Yellow/Red
(YL/RD)
(YL/RD)
Coordinating Remote
Coordinating Remote
(no LEDs)
(no LEDs)
Dimmer
not used
not used
WH
WH
Hot (Black)
not used
Black
Green
Green
Green
BL
BL
BL
Ground
Ground
Ground
YL/RD
YL/RD
YL/RD
RD
RD
RD
Load
120VAC, 60Hz
White
Neutral (White)
WIRING COORDINATING REMOTE (4-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
• Green or bare copper wire in wall box to Green terminal screw.
• First Traveler and Third Traveler wall box wire (note wire colors) to
terminal screw marked "RD". These travelers from the remote in the 4-way
box must go to the terminal screw on the dimmer marked "RD" or Red
dimmer lead, and to the terminal screw marked "RD" of the remaining
remote in the 3-way box.
• Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire (note
wire colors) to terminal screw marked "YL/RD". These travelers from the
remote in the 4-way box must go to the terminal screw on the dimmer marked
"YL/RD" or the Yellow/Red dimmer lead, and to the terminal screw marked
"YL/RD" of the remaining remote in the 3-way box.
• Remote terminal screw marked "WH" should have White insulation label
affixed.
NOTE: If insulating label is not affixed to terminal screw marked "WH",
use electrical tape to cover. Remote terminal screw marked "BL" is not used.
Use electrical tape to cover.
WIRING DIMMER (3-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer can be
installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes cannot
exceed 300 ft.
• Green or bare copper wire in wall box to Green terminal screw or Green
dimmer lead.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch to dimmer terminal screw marked "BL" or Black dimmer lead.
• First Traveler wall box wire to dimmer terminal screw marked "RD" or
Red dimmer lead (note wire color as above). This traveler from the
dimmer must go to the terminal screw on the remote marked "RD".
• Remove Red insulating label from terminal screw marked "YL/RD" or
Yellow/Red dimmer lead.
• Second Traveler wall box wire to dimmer terminal screw marked "YL/RD"
or Yellow/Red dimmer lead (note wire color as above). This
traveler from the dimmer must go to the terminal screw on the
remote marked "YL/RD".
WIRING COORDINATING REMOTE (3-Way box):
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
• Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch to
terminal screw marked "BL".
• First Traveler wall box wire (note color as above) to terminal screw
marked "RD". This traveler from the remote must go to the terminal
screw on the dimmer marked "RD" or the Red dimmer lead.
• Second Traveler wall box wire (note color as above) to terminal screw
marked "YL/RD". This traveler from the remote must go to the terminal
screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead.
• Remote terminal screw marked "WH" should have White insulation
label affixed.
NOTE: If insulating label is not affixed to terminal screw marked "WH",
use electrical tape to cover.
• Proceed to Step 6.
3-Way Wiring with Matching Remote (w/LEDs)
Step 5c
Application:
NOTE: Incandescent and Magnetic Low-Voltage installations
only. NOTE: Screw terminal dimmer depicted.
Matching Remote
Dimmer
Terminal
Additional
Screw marked
Neutral Wire
White (WH)
4
2
Terminal
1
Screw marked
2
Black (BL)
4
2
3
3
Terminal
1
Screw marked
5
5
Yellow/Red
(YL/RD)
Matching Remote (with LEDs)
Dimmer
Hot (Black)
WH
Green
Ground
BL
BL
Black
Green
RD
Ground
YL/RD
YL/RD
Line
Load
120VAC, 60Hz
White
Neutral (White)
Line
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box
with a Line Hot connection and a Neutral connection. A neutral wire
to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualified electrician.
NOTE: Maximum wire length from dimmer to all installed remotes cannot
exceed 300 ft.
WIRING MATCHING REMOTE (wall box with Line Hot connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch and First Traveler to dimmer terminal screw marked "BL" or the
Black dimmer lead.
• Second Traveler wall box wire from dimmer to remote terminal screw marked
"YL/RD" (note wire color). This traveler from must go to the terminal
screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead.
• Line Neutral wall box to remote terminal screw marked "WH".
WIRING DIMMER (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw or Green
dimmer lead.
• Load wall box wire identified (tagged) when removing old switch to
dimmer terminal screw marked "RD" or the Red dimmer lead.
• First Traveler Line Hot to dimmer terminal screw marked "BL" or the Black
dimmer lead.
• Remove Red insulating label from terminal screw marked "YL/RD" or
Yellow/Red dimmer lead.
• Second Traveler wall box wire (note color as above) to dimmer
terminal screw marked "YL/RD" or the Yellow/Red dimmer lead. This
traveler from the dimmer must go to the terminal screw on the remote
marked "YL/RD".
• Proceed to Step 6.
4-Way Wiring with Matching Remote (w/LEDs)
Step 5d
Application:
NOTE: Incandescent and Magnetic Low-Voltage
installations only.
NOTE: Screw terminal dimmer depicted.
Matching Remote
Matching Remote
Dimmer
(3-Way Wall box from Step 2)
(4-Way Wall box from Step 2)
(3-Way Wall box from Step 2)
Terminal
Terminal
Screw marked
Additional
Screw marked
Additional
White (WH)
Neutral Wire
White (WH)
Neutral Wire
4
2
3
Terminal
Terminal
1
Screw marked
1
Screw marked
Black (BL)
Black (BL)
5
4
3
4
3
Terminal
Terminal
1
2
Screw marked
Screw marked
Yellow/Red
5
Yellow/Red
5
6
(YL/RD)
(YL/RD)
Matching Remote
Matching Remote
(with LEDs)
(with LEDs)
Dimmer
Hot (Black)
WH
WH
Green
Ground
BL
BL
BL
Black
Green
Green
YL/RD
YL/RD
RD
YL/RD
Ground
Ground
Line
120VAC, 60Hz
White
Neutral (White)
2
Load

Advertisement

loading

Summary of Contents for Leviton AC00R-10

  • Page 1 Eco-10™ (EcoSeries) electronic ballast applications, use instruction sheet that comes with the dimmer for multi-location applications. • Acenti™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Acenti™ remotes for multi-location dimming.
  • Page 2 Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation.

This manual is also suitable for:

Ac00r-1lAc0sr-10Ac0sr-1l