ASP SSP Installation, Operation & Maintenance Instructions Manual

Advertisement

Quick Links

Installation Operation & Maintenance Instructions
Model SSP & SSPC

Description and Specifications

back-pullout centrifugal pump. The model SSPC is the enclosed impeller version of the same pump. Connections are
NPT threaded. All wetted metal pump parts are 18-8, 304SS, or better. Most parts are formed from stainless steel
sheet. O-rings and elastomeric seal parts are Buna (Viton, EPR are optional). Motors are NEMA 56J frame, with a C-
Face mounting flange and a threaded shaft. All pumps use a mechanical seal to prevent leakage around the motor
shaft.
Operating limits:
The models SSP & SSPC are designed for 75-PSIG operating pressure at 212 deg. F., with the
standard Type-6, carbon vs. ceramic with buna-n elastomers mechanical seal, and a maximum temperature limit of 250
deg. F., with a Type-21 mechanical seal with viton elastomers. The motor is limited to 20 starts per hour, evenly
distributed.
Notice: Upon receipt of this equipment, inspect the carton and the equipment for any dam-
ages that might have occurred during shipment and notify the carrier immediately.
that occurs during shipment is not the responsibility of American Stainless Pumps. Failure to notify the carrier will place
responsibility on the purchaser for any repairs or damages occurring during shipment.
Safety Instructions: To avoid serious or fatal injury and/or property damage, read and follow
all instructions in this manual. Review all instructions and warnings included in this manual
before attempting any work on this pump or pump/motor assembly. Do not remove or alter
any decals.
The motor used to drive this pump is an electrical device connected to a potentially lethal
voltage power source. Take all precautions required when working with or on the motor
and its power source, including but not limited to:
1.
Always disconnect and lockout the electrical power source before attempting any connection, maintenance or
repairs. Failure to do so can cause electrical shocks, burns and death.
2.
Install, ground and wire motors in accordance with all local and national electrical codes.
3.
Install an all leg disconnect switch near the motor for quick access.
4.
The electrical supply must match the motor nameplate specifications and the motor must be wired per the
wiring diagram on the motor to match the selected voltage. Incorrect wiring can cause fire and motor
damage and will void the warranty.
5.
Most single-phase motors and some three phase motors will have automatic thermal protection switches
wired in the motor. These switches will open and stop the motor if the motor overheats. As the motor
cools, these switches will close and start the motor automatically and unexpectedly.
6.
Motors which do not have thermal overloads must have a properly sized contractor or magnetic starters and
overload switches (or fuses) in the starter panel. Three phase motors require all leg protection.
7.
Use only stranded copper wire to motor and ground. Wire size must limit the maximum voltage drop to 10%
of the motor nameplate voltage at the motor terminals.
8.
Three phase motors can rotate in either direction. The pump will operate properly only in one direction
(clockwise when looking from the motor end, counterclockwise when viewed from the pump end). Operat-
ing the pump in the reverse rotation may damage or destroy the pump and motor and voids the
warranty.
www.aspumps.com
American Stainless Pumps
Stainless Steel Pumps for the Commercial Marketplace
: The Model SSP is a close coupled, end suction, single stage, open-impeller,
14032 S. Avalon Blvd. Los Angeles, CA 90061
Phone: (310) 630-8089 Fax: (310) 630-8095
Damage
3/1/2001
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ASP SSP

  • Page 1 Operating limits: The models SSP & SSPC are designed for 75-PSIG operating pressure at 212 deg. F., with the standard Type-6, carbon vs. ceramic with buna-n elastomers mechanical seal, and a maximum temperature limit of 250 deg. F., with a Type-21 mechanical seal with viton elastomers. The motor is limited to 20 starts per hour, evenly distributed.
  • Page 2  Install a valve on the discharge line for use in regulating the pump flow and for isolating the pump during maintenance and inspection. Rotation: The models SSP & SSPC will operate properly only in one direction (clockwise when looking from the motor end, Operating the pump in the reverse rotation may counterclockwise when viewed from the pump end).
  • Page 3 20 psig generates about 150 pounds of thrust. This thrust load is carried by the motor bearing. The standard jet pump motor and the standard SSP motor uses as a front and rear bearing a size 203 grease lubricated bearing.
  • Page 4 Model SSP Only: Join up the back pull out assembly with the case. Install the (8) case bolts (item 7CS), leaving the bottom two bolts loose for attaching the base (not necessary with footed motors). Slip the baseplate under the bottom two bolts.
  • Page 5  See SSP Performance Notes for impeller shimming discussion.  Properly setting the impeller to case clearance is the most critical factor in determining the SSP’s perfor- mance. You will get maximum performance and efficiency (and maximum amp draw) with near to zero clearance.
  • Page 6 Stainless Steel Pumps for the Commercial Marketplace Model SSP Impeller Shimming Method for Replacement Impellers When replacing impellers in a model SSP open impeller pump, the following worksheet will provide a relatively quick method for maintaining the proper impeller/casing clearance. You may also want to read the previous page for an overview of the impeller shimming procedure.
  • Page 7 American Stainless Pumps Stainless Steel Pumps for the Commercial Marketplace SSP (Open Impeller) Cross Sectional Drawing Item No. Part Description Standard Materials Casing 304 SS Impeller (Open) 304 SS Mechanical Seal - Type 6 (std.) Car/Cer/Buna N/316 SS (Other seal types available)
  • Page 8 American Stainless Pumps Stainless Steel Pumps for the Commercial Marketplace SSPC (Enclosed Impeller) Cross Sectional Drawing Item No. Part Description Standard Materials Casing 304 SS Impeller (Enclosed) 304 SS Mechanical Seal - Type 6 (std.) Car/Cer/Buna N/316 SS (Other seal types available) (Other m aterials available) Seal Plate 304 SS...

This manual is also suitable for:

Sspc

Table of Contents