◆ Sporadically occurring faults (temporary faults) will be indicated on the V.A.G 1551 display as "SP". The
word "sporadic" means "intermittent" or "occurring at irregular intervals".
◆ Components that are indicated as being faulty by the V.A.G 1551/VAS 5051 should not be renewed imme‐
diately. Always start by checking the wiring, connectors and earth connections for the component using the
current flow diagram. This is particularly important in the case of sporadic faults (indicated by the letters
"SP"on the fault reader display).
Fault code
SAE
V.A.G
P0102
16486 Air mass meter -G70
Signal too small
P0103
16487 Air mass meter -G70
Signal too large
P0112
16496 Intake air temp. sender -G42
Signal too small
P0113
16497 Intake air temp. sender -G42
Signal too large
P0116
16500 Coolant temp. sender -G62
Implausible signal
P0117
16501 Coolant temp. sender -G62
Signal too small
P0118
16502 Coolant temp. sender -G62
Signal too large
Fault code
SAE
V.A.G
P0130
16514
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
P0131
16515
with respect to the correctness of information in this document. Copyright by AUDI AG.
P0132
16516
P0134
16518
Fault code
SAE
V.A.G
P0150
16534
Bank 2, Probe 1
Electrical fault in current circuit
P0151
16535
Bank 2, Probe 1
Voltage too low
P0152
16536
Bank 2, Probe 1
Voltage too high
P0154
16538
Bank 2, Probe 1
No activity
P0321
16705
Engine speed sender -G28
Implausible signal
P0322
16706
Engine speed sender -G28
No signal
Fault code
Readout on fault reader display
SAE V.A.G
6
01 - Self-diagnosis
Readout on fault reader display
Readout on fault reader display
Bank 1, Probe 1
Electrical fault in current circuit
Bank 1, Probe 1
Voltage too low
Bank 1, Probe 1
Voltage too high
Bank 1, Probe 1
No activity
Readout on fault reader display
Fault rectification
Test air mass meter
=> Page
45
Test intake air temperature sender
=> Page
49
Test coolant temperature sender
=> Page
51
Fault rectification
Test lambda control
=> Page
Fault rectification
Test lambda control
=> Page
Test engine speed sender
=> Page
Fault rectification
52