TS8200D Series
Micro-Meter Mix Quick Start Guide
2.2 Calibrating the Pumps
The TS8200D Micro-Meter Mix needs to be calibrated before operation. Go to the
TS580D Controller User Guide for calibration instructions. Return here once
calibration has been completed.
3. DETERMINING CONTROLLER SETTINGS AND FINAL SET-UP
To determine and enter the correct settings and ratio for Resin (Pump 1) and
Hardener (Pump 2), please refer to TS580D Controller User Guide for
instructions on setting up the forward run settings, reverse run settings, ratio
settings, and dispense mode settings.
a. Remove calibration adapter.
b. Install dispense adaptor required for
corresponding static mixing nozzle.
For using 1:1/2:1 bayonet socket type
The static mixing nozzle can be mounted directly onto the pump using the
already installed 1:1/2:1 K-type nozzle locking plate.
c. Align the holes and rotating cap of the mixing nozzle with the holes of the
fluid manifold and "keyed" entry of the base plate adaptor.
d. Insert the nozzle and make sure it rests evenly with the base of the fluid
manifold. Lock into place by rotating the mixing nozzle's rotating cap
counterclockwise.
e. Pull on the nozzle to confirm it is securely locked into place.
techcon.com/contact-us
7