h. Install calibration adaptor. The calibration adaptor is required whenever
calibration is performed, when a new fluid is introduced, when the valve is
disassembled & reassembled, or when the stators or rotors are changed.
Connecting calibration adaptor can protect the TS8200D from having direct
contact with the material as it exits the pump.
i.
Mount the 1:1/2:1 K-type Nozzle Locking Plate and use a 2.0 mm hex wrench to
fasten screws into place.
i.
Mount the calibration adaptor and use a 2.5 mm hex wrench to fasten screws
into place.
ii.
Make sure that the calibration adaptor rest evenly against the nozzle locking
plate.
2. DISPENSING
Tip: Avoid over-tightening vent screws. Over-tightening may lead to tears to the
vent seal O-ring.
a. Connect the fluid supply to the fluid inlet of the pump. If
using a fluid reservoir, reference the "Accessories"
Section for information on compatible fluid lines. Make
sure the resin is connected to the pump with the "RESIN"
label and the hardener is connected to the pump with the
"HARDENER" label.
b. Connect the pump to the controller.