Model 176M12 Charge Output Pressure Sensor Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
Page 2
Returning Equipment – Following the equipment to PCB Piezotronics for these procedures will insure that your repair. User servicing or repair is not returned materials are handled in the recommended and, if attempted, may most expedient manner.
Page 3
PCB Piezotronics, Inc. Warranty – All equipment and repair 3425 Walden Ave. services provided by PCB Piezotronics, Depew, NY 14043 USA Inc. are covered by a limited warranty Toll-free: (800) 828-8840 against defective...
Page 10
Model Number Revision C CHARGE OUTPUT PRESSURE SENSOR 176M12 ECN #: 41257 Performance ENGLISH Optional Versions (Optional versions have identical specifications and accessories as listed Sensitivity (±20 %) 17 pC/psi 2.47 pC/kPa for standard model except where noted below. More than one option maybe used.)
Page 11
ICP® is a registered trademark of PCB group, Inc.
Page 12
Model Number Revision C CHARGE OUTPUT PRESSURE SENSOR 176M12 ECN #: 41257 Performance ENGLISH Optional Versions (Optional versions have identical specifications and accessories as listed Sensitivity (±20 %) 17 pC/psi 2.47 pC/kPa for standard model except where noted below. More than one option maybe used.)
Page 13
ICP® is a registered trademark of PCB group, Inc.
Page 14
Model Number Revision C CHARGE OUTPUT PRESSURE SENSOR 176M12 ECN #: 41257 Performance ENGLISH Optional Versions (Optional versions have identical specifications and accessories as listed Sensitivity (±20 %) 17 pC/psi 2.47 pC/kPa for standard model except where noted below. More than one option maybe used.)
Page 15
ICP® is a registered trademark of PCB group, Inc.
Page 16
ATEX Approved Sensors Pressure Sensors (Models 176 Series) English This sensor has been approved for Hazardous Locations Directive 94/9/EC, Ex nA IIC T4, Ex nA IIC T1, Ex ia IIC T4 and Ex ia IIC T1. For safe use: All applicable local electrical laws must be followed The supply electrical parameters must not exceed any of the following values: Uo ≤30V, Io≤300mA, Po≤1W, C≤5nF, L≤...
Page 17
Norsk Denne sensoren godkjenner for Farlige Plasseringer Direktiv 94/9/EC, Ex nA IIC T4, Ex nA IIC T1, Ex ia IIC T4 og Ex ia IIC T1. For sikker bruk: Alle anvendelige lokale elektriske lover fulgt Forsyningen elektriske parametre må ikke overskride noe av de følgende verdiene: Uo ≤30V, Io≤300mA, Po≤1W, C≤5nF, L≤...