Chauvet Professional OVATION B-1965FC User Manual

Hide thumbs Also See for OVATION B-1965FC:
Table of Contents

Advertisement

Quick Links

User Manual
Model ID: OVATIONB1965FC

Advertisement

Table of Contents
loading

Summary of Contents for Chauvet Professional OVATION B-1965FC

  • Page 1 User Manual Model ID: OVATIONB1965FC...
  • Page 2 Edition Notes The Ovation B-1965FC User Manual includes a description, safety precautions, installation, programming, operation and maintenance instructions for the Ovation B-1965FC as of the release date of this edition. Trademarks Chauvet, Chauvet Professional, the Chauvet logo, and Ovation are registered trademarks or trademarks of Chauvet &...
  • Page 3: Table Of Contents

    7-Cell RGBAL FULL 96CH / RGBAL Fine 70CH ..........7-Cell RGBAL EXT 59CH / RGBA EXT 52CH / RGB EXT 45CH ..... 7-Cell RGBAL 35CH / RGBA 28CH / RGB 21CH ..........TOC 1 Ovation B-1965FC User Manual Rev. 8...
  • Page 4 System Information .................... Factory Reset..................... Web Server ....................24 Home........................Settings ......................Output ........................ Security ......................5. Technical Information ..............Product Maintenance ..................25 6. Technical Specifications ............Returns.................... Contact Us ..................TOC 2 Ovation B-1965FC User Manual Rev. 8...
  • Page 5: Before You Begin

    This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Page 1 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 6: Safety Notes

    LEDs, contributing to shorter lifespans if always used at full intensity. The average LED lifespan is 40,000 to 50,000 hours. To extend LED lifespan, maintain proper ventilation around the product, and limit the overall intensity. Page 2 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 7: Introduction

    2. Introduction Description The Ovation B-1965FC has extended color capabilities and color renderings of the RGBA-Lime color mixing system, which offers a 1.2 m batten for stage and theatre lighting. It responds to RDM, Art-Net™, sACN, and to standard DMX control.
  • Page 8: Product Dimensions

    8.13 in 207 mm 19.8 in 504 mm 3.57 in 90.8 mm 30.2 in 8.13 in 766.8mm 207 mm 48.3 in 1228 mm 5.04 in 128 mm 8.26 in 210 mm Page 4 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 9: Setup

    DMX Connection You can link the Ovation B-1965FC to a DMX controller using a 3- or 5-pin DMX data connection. If using other DMX-compatible products with this product, you can control each individually with a single DMX controller. Art-Net™ Connection Art-Net™...
  • Page 10: Master/Slave Connection

    ETUP Master/Slave Connection The Ovation B-1965FC uses the DMX data connection for its Master/Slave mode. See the User Manual for information about connect and configure the product for master/slave operation. RDM (Remote Device Management) Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally along existing DMX cabling.
  • Page 11: Mounting

    Floor stand Web Server The Ovation B-1965FC Web Server can be accessed by any computer on the same network as the product. It allows network access to system information, settings such as control protocol and starting address, color output testing, and the ability to change the Web Server password.
  • Page 12: Operation

    Press <ENTER> to select. In this case, if there is another programming level, you will see that first option, or you will see the selected value. • Press <MENU> repeatedly to exit to the previous main level.Ovation B-1965FC Menu Map Refer to the Ovation B-1965FC product page on www.chauvetprofessional.com...
  • Page 13 C6170 - Dk Magenta C6020 - Lt Lavender C5030 - Lt Blue C5020 - VLt Blue C5430 - Lt Blue 2 C5070 - Blue C5050 - Md Blue C5060 - Dk Blue Page 9 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 14 Speed 1-100 and auto program speed Auto 6 Auto 7 Auto 8 Auto 9 Fade Red shift on Red Shift Red shift off Master Master mode Master/ Slave Slave Slave mode Page 10 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 15 Device ID _ _ _ _ _ _ _ _ _ Shows product device ID UID: _ _ _ _ _ _ _ _ _ _ _ _ Shows product UID Page 11 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 16 PERATION Main Level Programming Levels Description Factory Resets to factory defaults Setting Page 12 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 17: Configuration (Dmx/Art-Net™/Sacn)

    Use control configurations to operate the product with a controller. Control Protocol This setting allows you to choose the protocol with which to control the Ovation B-1965FC. Go to the Protocol main level. Select the desired control protocol (DMX512, ArtNet, or sACN).
  • Page 18: 7-Cell Dmx Values

    000  255 0–100% Green fine 4 000  255 0–100% Blue 4 000  255 0–100% Blue fine 4 000  255 0–100% Amber 4 000  255 0–100% Page 14 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 19 Strobe, slow to fast 000  010 No function – Strobe all 011  255 Strobe, slow to fast 000  015 No function – Color macros 016  255 Color macros Page 15 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 20: 7-Cell Rgbal Ext 59Ch / Rgba Ext 52Ch / Rgb Ext 45Ch

    011  255 Strobe, slow to fast Red 4 000  255 0–100% Green 4 000  255 0–100% Blue 4 000  255 0–100% – Amber 4 000  255 0–100% Page 16 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 21 000  010 No function Strobe 7 011  255 Strobe, slow to fast 000  010 No function Strobe all 011  255 Strobe, slow to fast Page 17 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 22: 7-Cell Rgbal 35Ch / Rgba 28Ch / Rgb 21Ch

    000  255 0–100% Green 7 000  255 0–100% Blue 7 0–100% 000  255 – Amber 7 000  255 0–100% – – Lime 7 000  255 0–100% Page 18 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 23: 7-Cell Hsv 21Ch

    000  010 No function – Strobe 011  255 Strobe, slow to fast 000  015 No function – Color macros 016  255 Color macros Page 19 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 24: 1-Cell Rgbal Ext 10Ch / Rgba Ext 9Ch / Rgb Ext 8Ch

    Refer to the Color Temperature Chart section for specific values 1-Cell HSV 3CH Channel Function Value Percent/Setting 000  255 0–100% Saturation 000  255 0–100% Value 000  255 0–100% Page 20 of 35 Ovation B-1965FC User Manual Rev. 8...
  • Page 25: Virtual Color Wheel

    PERATION Virtual Color Wheel The Ovation B-1965FC includes a feature called the Virtual Color Wheel (VCW). This feature is available as a standalone control mode for manual use and as a control channel in select DMX personalities. More than 30 pre-mixed colors, custom blended by our engineers, are available to call up for easier programming.
  • Page 26: Configuration (Standalone)

    Go to the Red Shift main level. Select from On or Off). Master/Slave The Master/Slave mode allows a group of Ovation B-1965FC products (the slaves) to simultaneously duplicate the output of another Ovation B-1965FC (the master) without a DMX controller. To set each of the slaves: Go to the Master/Slave main level Select Slave.
  • Page 27: Dimmer Curve

    Inverse Square: The output follows an inverse square-law curve. Dimmer Mode This setting determines how fast the output of the Ovation B-1965FC changes when you modify the output value. This setting provides four different options to simulate the dimming curve of an incandescent lighting product.
  • Page 28: System Information

    Select No or Yes. Web Server The Ovation B-1965FC Web Server can be accessed by any computer on the same network as the product. It allows network access to system information, settings such as control protocol and starting address, color output testing, and the ability to change the Web Server password.
  • Page 29: Technical Information

    ECHNICAL 5. Technical Information Product Maintenance To maintain optimum performance and minimize wear, clean this product frequently. Usage and environment are contributing factors in determining the cleaning frequency. Clean this product at least twice a month. Dust build-up reduces light output performance and can cause overheating.
  • Page 30: Technical Specifications

    ECHNICAL PECIFICATIONS 6. Technical Specifications Dimensions and Weight Length Width Height Weight 48.43 in (1,230 mm) 8.27 in (210 mm) 8.15 in (207 mm) 32 lb (14.5 kg) Note: Dimensions in inches rounded to the nearest hundredth. Power Power Supply Type Range Voltage Selection Switching (internal)
  • Page 31: Returns

    ETURNS Returns Send the product prepaid, in the original box, and with the original packing and accessories. Chauvet will not issue call tags. Call Chauvet and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause(s) for the return.
  • Page 32: Contact Us

    ONTACT Contact Us General Information Technical Support Chauvet World Headquarters Address: 5200 NW 108th Ave. Voice: (844) 393-7575 Sunrise, FL 33351 Fax: (954) 756-8015 Voice: (954) 577-4455 Email: chauvetcs@chauvetlighting.com Fax: (954) 929-5560 Toll Free: (800) 762-1084 Website: www.chauvetprofessional.com Chauvet U.K. Address: Unit 1C Email: UKtech@chauvetlighting.eu...

This manual is also suitable for:

03031296

Table of Contents