New electric control box material changes from metal to plastic, which not only reduces the weight, but also avoids the short circuit caused by the PCB touching the metal box. 1.4 System design 1.4.1 Anticorrosive components design, leading to longer service live. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 6
Different indoor units for choice. You can choose different indoor units appearance for your favorite. 1.5.2 Much more indoor units for free combination, meeting for different requirement such as office, house use, villa and etc. One or more indoor units’ connection combination for your choice. 1.5.3 GD Chigo Heating & Ventilation Equipment Co., Ltd.
R32 DC Inverter Multi-split Technical Manual General Information 4. External Appearance 4.1 Indoor Units Wall Mounted 150 Series 155 Series 156 Series Ducted Units 4-way compact Cassette GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 12
R32 DC Inverter Multi-split Technical Manual General Information 4.2 Outdoor Units DC Dual-split DC Triple split DC Fourfold & Fivefold split GD Chigo Heating & Ventilation Equipment Co., Ltd.
The different style panels can satisfy your different requirements. All the units have various functions, such as the function of auto-restart, sleep mode are standard, golden fins and some filter for optional. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 22
3. Sound level: measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 4. The above data may be changed without notice for future improvement on quality and performance. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Indoor unit outline mm or 120 mm or more to wall more to wall Right rear side refrigerant pipe hole Left rear side refrigerant pipe hole Model A(mm) B(mm) ≤12000Btu/h 18000Btu/h 24000Btu/h 1200 GD Chigo Heating & Ventilation Equipment Co., Ltd.
( 12K ) 155,156 ( 9K ) Type Type choice choice2 Remark: OFF ON 1、Make Memory short-circuit is a power outage memory otherwise for nothing 2、According to the specific models to dial the code GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 26
R32 DC Inverter Multi-split Technical Manual Indoor Units CSG-18HVR4-A、CSG-24HVR4-A GD Chigo Heating & Ventilation Equipment Co., Ltd.
R32 DC Inverter Multi-split Technical Manual Indoor Units 8. Sound Level Air outlet side M i crophone Noise leveldB(A) Model High speed CSG-07HVR4-A(150) CSG-07HVR4-A(155) CSG-07HVR4-A(156) CSG-09HVR4-A(150) CSG-09HVR4-A(155) CSG-09HVR4-A(156) CSG-12HVR4-A(150) CSG-12HVR4-A(155) CSG-12HVR4-A(156) CSG-18HVR4-A(150) GD Chigo Heating & Ventilation Equipment Co., Ltd.
R32 DC Inverter Multi-split Technical Manual Indoor Units 9. Exploded View 150 series GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 39
Fixing tube panel Indoor motor Cross flow fan Motor cover assy Base assy Evaporator components Remote control battery Evaporator assy Chigo Elf general remote General manual plastic bag of export Evaporator damping rubber strip GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 40
R32 DC Inverter Multi-split Technical Manual Indoor Units 155 series GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 41
Fixing tube panel Indoor motor Cross flow fan Motor cover assy Base assy Evaporator components Remote control battery Evaporator assy Chigo Elf general remote General manual plastic bag of export Evaporator damping rubber strip GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 42
R32 DC Inverter Multi-split Technical Manual Indoor Units 156 series GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 43
Fixing tube panel Indoor motor Cross flow fan Motor cover assy Base assy Evaporator components Remote control battery Evaporator assy Chigo Elf general remote General manual plastic bag of export Evaporator damping rubber strip GD Chigo Heating & Ventilation Equipment Co., Ltd.
1.2 Adopting aviation centrifugal fans, and CFD technology design, increasing air-volume and decreasing noise level. 1.3 Three fan speed, meet different requirement. 1.4 High efficiency DC fan motor, low noise and more comfortable. Operate in low frequency and control indoor temperature precisely. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 47
R32 DC Inverter Multi-split Technical Manual Indoor Units 1.5 E-box is body-side design, convenient installation and maintenance. GD Chigo Heating & Ventilation Equipment Co., Ltd.
3. Sound level: measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 4. The above data may be changed without notice for future improvement on quality and performance. GD Chigo Heating & Ventilation Equipment Co., Ltd.
R32 DC Inverter Multi-split Technical Manual Indoor Units 4. Service Space Ensure enough space required for installation and maintenance. GD Chigo Heating & Ventilation Equipment Co., Ltd.
R32 DC Inverter Multi-split Technical Manual Indoor Units 5. Wiring Diagrams CST-07HVR4-A/CST-09HVR4-A/CST-12HVR4-A/CST-18HVR4-A Control l e r WAT ER S WITCH P UMP YE/GN Ri n g us er s elec ti o n Connect to the outdoor GD Chigo Heating & Ventilation Equipment Co., Ltd.
Installation instruction for indoor The manual unit Insulating tube Ribbon Dome insulated tip X-type insulated tip Wireless controller Connecting pipe of electronic expansion valve Connection wire for wired controller Blank valve bag GD Chigo Heating & Ventilation Equipment Co., Ltd.
1.1 New developed panel. Indoor unit. Indoor unit uniform standard panel, simple and convenient. 1.2 Ultra-thin body design, the min. height is only 267mm, save installation space. 1.3 Built-in water pump,water head up to 700 mm. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 67
1.5 Built in water tray, insulating foam coated by special plastic, preventing the leakage of the condensed water effectively 1.6 Standard for wireless controller; option for wired controller. Standard optional GD Chigo Heating & Ventilation Equipment Co., Ltd.
3. Sound level: measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 4. The above data may be changed without notice for future improvement on quality and performance. GD Chigo Heating & Ventilation Equipment Co., Ltd.
R32 DC Inverter Multi-split Technical Manual Indoor Units 4. Service Space Ensure enough space required for installation and maintenance. Model Machine body height(H) 7K/9K/12K/18K GD Chigo Heating & Ventilation Equipment Co., Ltd.
Fault of indoor temperature sensor LED running shines quickly Alarming fault of water level LED alarming light shines quickly Mode impact fault LED defrost light shines quickly Outdoor unit fault LED alarming light shines slowly GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 86
R32 DC Inverter Multi-split Technical Manual Indoor Units EEPROM malfunction LED defrost light shines slowly GD Chigo Heating & Ventilation Equipment Co., Ltd.
1.2 Soft start, the start current of the compressor is small and smooth. 1.3 Easy piping and wiring connection, no welding and only flare nut connection which makes the installation work easy and convenient. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 88
(Between each IU Max. pipe length and OU) Max. height difference 3×2.5 mm 3×2.5 mm Power wiring Connection wiring 4×1 mm 4×1 mm Signal wiring ˚C -15~52 -15~48 Ambient temperature Application area 2×(10~15) 2×(12~18) GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 89
Max. pipe length (Between each IU and OU) Max. height difference 3×4 mm 3×4 mm Power wiring Connection wiring 4×1 mm 4×1 mm Signal wiring ˚C -15~52 -15~52 Ambient temperature Application area 3×(10~15) 3×(12~18) GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 90
OU) Max. height difference 3×6 mm 3×6mm 3×6mm Power wiring Connection wiring 4×1 mm 4×1 mm 4×1 mm Signal wiring ˚C -15~52 -15~52 -15~52 Ambient temperature Application area 4×(10~15) 4×(12~18) 5×(12~18) GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 91
3. Sound level: measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 4. The above data may be changed without notice for future improvement on quality and performance. GD Chigo Heating & Ventilation Equipment Co., Ltd.
C api l l ary O i l separat or G as val ve A S hutof f val ve C om pressor G as val ve B C3OU-21HDR4-A C3OU-27HDR4-A GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 95
Condenser Coil temp EXVC sensor 4-way valve Filter D Capillary D Liquid valve D Oil separator Gas valve A Compressor Gas valve B Gas valve C Shutoff valve Gas valve D C5OU-42HDR4-A GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 96
Capillary D Liquid valve D Oil separator EXVE Filter E Capillary E Liquid valve E Gas valve A Compressor Gas valve B Gas valve C Shutoff valve Gas valve D Gas valve E GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 133
R32 DC Inverter Multi-split Technical Manual Outdoor Units 21.6 length of straight pipe single-axis DC fan motor 21.7 Probe of copper pipe axial fan blade 21.8 condenser retaining clip fan motor holder assembly GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 134
R32 DC Inverter Multi-split Technical Manual Outdoor Units C5OU-42HDR4-A GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 135
21.3 Distributing capillary assembly Valve holder part 21.4 L-shape pipe low pressure valve welding assembly 21.5 process pipe high pressure valve welding 21.6 length of straight pipe assembly GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 136
R32 DC Inverter Multi-split Technical Manual Outdoor Units 21.7 Probe of copper pipe axial fan blade 21.8 condenser retaining clip fan motor holder assembly single-axis DC fan motor GD Chigo Heating & Ventilation Equipment Co., Ltd.
Display H6 for 3 times within 100 Exhaust overheating protection minutes T3 high temperature protection Display H4 after P6 protection for 3 Module protection times within 30 minutes DC fan fault Display H9 after P9 protection for 2 GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 138
MCE fault/sync/closed loop Zero speed protection Phase sequence error protection Protection when the speed change of two successive periods exceed 15Hz Protection of speed change(>15Hz) for the previous time and next time GD Chigo Heating & Ventilation Equipment Co., Ltd.
Take the air conditioner weight into account and select a place where noise and vibration will not be an issue. Select a place so that the warm air and noise from the air conditioner do not disturb neighbors. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Consult local codes regarding rooftop mounting. If the outdoor unit is installed on roof structures or external walls, this may result in excessive noise and vibration, and may also be classed as a non serviceable installation. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Flaring work Firmly hold copper pipe in a die in the dimension shown in the table below. Outer diam. A(mm) (mm) Max. Min. φ6.35 φ9.52 φ12.7 φ15.88 GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 143
Quintuple split indoor and outdoor units Difference in height between Max. 5m indoor units 3.3 Connection pipe diameter: Indoor unit Liquid Accessories φ6.35 φ9.52 7K/9K/12K φ6.35 φ12.7 Adapter φ9.52 φ15.88 Adapter component GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 144
6.35mm to 9.52mm,and connector diameter of indoor unit is 9.52mm. (3)The adapter component is included inside the accessory of indoor uint. GD Chigo Heating & Ventilation Equipment Co., Ltd.
● Open the valve stem until it hits against the stopper. Do not try to open it further. ● Securely tighten the valve stem cap with a spanner or the like. ● Valve stem cap tightening torque. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 146
7. Remove the charge hose from the Low pressure charge hose. 8. Fully open the packed valve stems B and A. 9. Securely tighten the cap of the packed valve. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 147
R410A DC Inverter Multi-split Technical Manual Control System Vacuum 1.For one drive two unit: Vacuum for two indoor units separately. 2.For one drive three unit: Vacuum for three indoor units separately. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 148
Vacuum from the main valve, no need vacuum for each indoor unit; b. Make sure main valve close before vacuum, then open all small valves for indoor units , keep the small valve close if there is no indoor unit. GD Chigo Heating & Ventilation Equipment Co., Ltd.
If bubblescome out, the pipes have leakage. ● Leak detector Use the leak detector to check for leakage. Caution: A,B,C,D and E are packed valve of outdoor unit. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 150
Note: The illustration is for explanation purpose only. The actual order of A,B,C,D and E on the machine may be slightly different from the unit you purchased. The actual shape shall prevail. GD Chigo Heating & Ventilation Equipment Co., Ltd.
The dimension of drainpipe can’t less than the connecting dimension of indoor drainpipe. Heat-insulation should be done well to prevent condensation. Indoor units with different drainage type can’t share one convergent drainpipe. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Insulation for non-jointing parts and non-connection parts. wrong Right Gas pipe and liquid pipe should not be Insulate the gas pipe (cooling only) Insulate the gas pipe and liquid pipe put together to insulate GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 153
Insulate for the jointing area, expanding area and the flange area should be done after checking leakage of the pipes Make sure there’s no clearance in the joining part of the accessorial insulation material and local preparative insulation material. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 154
The gas and liquid pipe should be heat insulated individually, the connecting part should be heat insulated individually. Use the attached heat-insulation material to insulate the pipe connections (pipes’ tie-in,expand nut ) of the indoor unit. GD Chigo Heating & Ventilation Equipment Co., Ltd.
R410A DC Inverter Multi-split Technical Manual Control System Part 5. Test Running 1. Dialing setting of main control board Switch No. Dialing Illustration GD Chigo Heating & Ventilation Equipment Co., Ltd.
Last fault protection code (no fault display -) Control parameters (only for use of Capacity need of indoor unit "B" development personnel),display "- -" Capacity need of indoor unit "C" Control parameters (only for use of GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 157
R410A DC Inverter Multi-split Technical Manual Control System development personnel) Capacity need of indoor unit "D" Capacity need of indoor unit "E" Definition of operation mode: 0-OFF/Fan; 2-Cooling; 3-Heating; 4-Forced cooling. GD Chigo Heating & Ventilation Equipment Co., Ltd.
4. Before power-on, make sure there is no short circuit. 5. Check if all units have passed 24-hour nitrogen pressure-maintaining (40kgf /cm2) test. 6. Make sure the debugged system is fully vacuumized, dried and filled with the refrigerant as specified. GD Chigo Heating & Ventilation Equipment Co., Ltd.
7. Check if the power supply phase sequence of the outdoor unit is correct. 8. Check if all dialing switches of the indoor and outdoor units are set according to the technical requirements of the product. GD Chigo Heating & Ventilation Equipment Co., Ltd.
When the multiple indoor units are arranged, in order to distinguish the connecting systems of indoor and outdoor units, all systems shall be named respectively and recorded on the nameplate on the electronic control box cover of the outdoor unit. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Calculate the indoor volume (B [m ]) (by the minimum volume) c) Calculate the refrigerant concentration. [] ≤ ∶ 0.3[/ [ GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 162
R410A DC Inverter Multi-split Technical Manual Control System 5. Measures against exceeding the critical concentration a) To reduce the refrigerant concentration below the critical concentration, install a mechanical ventilation device (for frequent ventilation). GD Chigo Heating & Ventilation Equipment Co., Ltd.
R410A DC Inverter Multi-split Technical Manual Control System Part 6. Controller 1. Wireless Remote Controller NT-03A USE OF REMOTE CONTROLLER: The icon meaning of remote controller GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 164
① When pressing this key, the remote controller switches by "on, off, on" circularly. ② When the first power on, the working state is set by default: setting temperature 25℃ (77℉), automatic mode, automatic fan speed, internal and external pendulum wind, no TURBO, no sleep, GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 165
① Pressing this key in the dehumidification mode, the external pendulum wind is forced to close. ② Pressing this key in the other modes, the external pendulum switches by "swing, fixed wind, swing" circularly. (6) Left and right swinging (Internal pendulum wind) GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 166
③ If the air conditioner has four gear wind speeds, the TURBO icon will light up and the fan will run in the fourth gear wind speed by pressing this key. (11) ECON GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 167
② When it is locked, the remote controller does not work except the lock key. (16) Combinatorial key: “FAN -” + “FAN +” ① Extension code remote controller has the effect. Switch 3 gear wind and 6 gear wind. There is 6 GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 168
2)Take off the back cover and remove the old batteries. When replacing batteries, please pay attention to the "+" and "-" marking on the battery. 3)Install the back cover and set the current time. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 169
The recommended service life is marked on the battery, but the actual service life may be shorter. GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 170
R410A DC Inverter Multi-split Technical Manual Control System 2. Wired Controller ZKX-C/TE-05 GD Chigo Heating & Ventilation Equipment Co., Ltd.
Page 171
R410A DC Inverter Multi-split Technical Manual Control System GD Chigo Heating & Ventilation Equipment Co., Ltd.