Download Print this page
Current COMPASS tradeselect CCRGRC Quick Start Manual

Current COMPASS tradeselect CCRGRC Quick Start Manual

Combination exit/emergency light

Advertisement

Quick Links

IMPORTANT:
When relamping, only use lamps specified in the exit sign.
Using other lamp types may result in transformer damage or unsafe conditions.
The battery in this unit may not be fully charged.
After electricity is hooked up to unit, let the battery charge up for at least 24 hours, then normal operation of this unit should take effect.
Ceiling Mounting
1. Connect 20" jumper leads to A.C. input leads in J-box, fasten J-box bracket to J-box. Use black wire for 120 volt, Red wire for 277
volt, White wire is common.
2. Fasten canopy to J-box bracket.
3. Snap housing to canopy.
4. Connect and trim input leads to socket leads at upper left comer of housing wire channel.
5. Mount two Remote lamp head at most.
6. Secure face plate to housing. Remove the proper arrow as required.
Back Mounting
1. Connect 20 "jumper leads toA.C. input leads in ]-box.Use Black wire for 120 volt,Red wire for 277 volt, White wire is common.
2. Remove necessary knockouts and fasten back cover to J-box.
3. Snap housing to back cover.
4. Connect and trim input leads to socket leads at upper left comer of housing wire channel.
5. Mount two Remote lamp head at most.
6) Secure face plate to housing.
Warning: Unused wires must be capped using
enclosed wire nuts.
CCRGRC/CCRGRCB/CCRG/CCRGB
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should
always be followed including the following.
READ AND FOLLOW ALL SAFETY
1. Do not use outdoors
2. Do not mount near gas or electric heaters.
3. Use caution when handling batteries. Avoid possible shorting.
4. Equipment should be mounted at heights (Max:9ft) to prevent tampering by unauthorized
personnel.
5. The use of accessory equipment is not recommended by the manufacturer, this may cause
unsafe conditions.
6. Do no use this equipment for other than the intended use.
7. Save these instructions
•SEE UNIT LABEL FOR ADDITIONAL MODEL SPECIFICATIONS
•SAVE THESE INSTRUCTIONS FOR USE BY OWNER/OCCUPANT
WARNING – This product contains chemicals known to the State of California to cause cancer, birth
defects and/or other reproductive harm. Thoroughly wash hands after installing, handling, cleaning,
or otherwise touching this product.
INSTALLATION
Combination Exit/Emergency Light
INSTRUCTIONS
INSTALLER:

Advertisement

loading

Summary of Contents for Current COMPASS tradeselect CCRGRC

  • Page 1 CCRGRC/CCRGRCB/CCRG/CCRGB Combination Exit/Emergency Light IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following. READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. Do not use outdoors 2. Do not mount near gas or electric heaters. 3.
  • Page 2 Operation 1. The unit is shipped from the factory with the color selector jumper set to "RED" (see figure 2 - jumper is placed across pins 2&3) and use the red diffuser. 2. To change the color to "GREEN", move the color selector jumper to "GREEN" (see figure I -jumper is placed across pins 1&2) and use the green diffuser.

This manual is also suitable for:

Compass tradeselect ccrgrcbCompass tradeselect ccrgCompass tradeselect ccrgb