JB HVG-001 Operating Manual

JB HVG-001 Operating Manual

Digital vacuum gauge

Advertisement

HVG-001
DIGITAL VACUUM GAUGE
OPERATING MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for JB HVG-001

  • Page 1 HVG-001 DIGITAL VACUUM GAUGE OPERATING MANUAL...
  • Page 2: Specifications

    SPECIFICATIONS Vacuum Reading Range 100,000 to 10 microns Working Temperature +32°F to 120°F (+0°C to 48.9°C) Power Supply Three AA batteries Dimensions 9" length x 3.25" width x 1.5" depth Shipping Weight .86lbs(.39kg) Warranty 12 months FEATURES Hook Audible and Visual Alarm Unit Selection Display Screen...
  • Page 3: Power Settings

    Press and hold POWER button for two seconds to power gauge on. If unit display does not light up, check for correct battery installation. Startup display will show “JB”, “JUST BETTER”, VER XXX (Version), a loading menu, followed by either the micron value or the over range indicator “oooooo.”...
  • Page 4: Battery Status Indicator

    When the battery voltage drops below 2.4 volts, the battery outline will flash and the unit will beep once per minute to alert the low battery condition. When battery voltage falls below 2.1 volts, the shutdown timer is activated. If voltage stays below 2.1 volts for thirty seconds, the HVG-001 will beep once and power off. Battery Status Indicator Battery Replacement If unit display does not light up after holding POWER button for two seconds, check for correct battery installation.
  • Page 5: Menu Settings

    4. To select a sub menu option, press and hold the ENTER button for three seconds to store the selection. Unit will display “STORED” and save your selection. Each time the HVG-001 powers on, stored user settings will be retrieved.
  • Page 6 Low Alarm Setting (LO--AL) The Low Alarm setting determines the pressure level for which an alarm will be sounded. Available alarm settings: OFF, 50, 100, 250, 500, 1000, 1250, 1500, 2000 microns. Factory default setting is “500” microns. The available alarm setting values will be displayed in the current unit selection setting. For example, if your current unit selection setting is in Pascals, your available settings will be: 7, 14, 33, 66, 133, 166, 200, and 266, the Pascal equivalents of the 50 –...
  • Page 7: Maintenance

    Note: Even if auto-shutdown has been deactivated, a low battery condition will power off the HVG-001. Connection Instructions It is recommended to connect the HVG-001 gauge hose directly to either the high or low side of the system for the most accurate reading.