JB Prowler LD 5000 User Manual

JB Prowler LD 5000 User Manual

Refrigerant leak detector
Hide thumbs Also See for Prowler LD 5000:

Advertisement

LD 5000 REFERIGERANT LEAK DETECTOR
JB INDUSTRIES INC.

Advertisement

Table of Contents
loading

Summary of Contents for JB Prowler LD 5000

  • Page 1 LD 5000 REFERIGERANT LEAK DETECTOR JB INDUSTRIES INC.
  • Page 2: Product Overview

    PRODUCT OVERVIEW JB Industries is proud to unveil the new, revolutionary LD 5000 PROWLER refrigerant gas leak detector. Using our new proprietary JBI Electrochemi- cal sensor technology for unparalleled accuracy coupled with the unique user features, there simply is no better hand held probe type service leak detector system on the market.
  • Page 3 IMPORTANT PLEASE READ BEFORE OPERATING YOUR PROWLER LD 5000 LEAK DETECTOR THE PROWLER EMPLOYS AN ULTRA SENSITIVE SENSOR AND AD- VANCED SOFTWARE THAT IS CAPABLE OF FINDING TINY LEAKS IN AC SYSTEMS. THE PROWLER SOFTWARE AUTOMATICALLY DETECTS CHANGES IN CONCENTRATION OF GAS. ONCE THE DETECTOR ALARMS, IT WILL ALARM AGAIN ONLY WHEN THE CONCENTRATION OF RE- FRIGERANT INCREASES.
  • Page 4 NEED A PICTURE of Control Panel POWER ON/OFF SENSITIVITY MUTE BUTTON BACKLIGHT BUTTON LEVEL HOW TO OPERATE 1) TURN ON: Press the ON/OFF button once to turn on and again to turn off. NOTE: Hold button down for approximately 1 second to turn unit off. 2) WARM UP: The detector automatically energizes the sensor condi- tioning it for use.
  • Page 5 LEAK SIZE INDICATOR The digital leak size indicating LCD graph display remains off normally but once a leak is detected, a number of indicating bars (up to 10 bars with increasing height) will be displayed for all HFC and HCFC refrigerants regardless of the sensitivity setting.
  • Page 6 BACKLIGHT To turn on the LCD display backlight, press the Backlight button once. Press again to turn off. LEAK TEST VIAL The leak detector comes with a Leak Test Vial that allows the user to make sure the detector is performing properly. To test: 1.
  • Page 7 Sensor: Replace Filter: Unscrew sensor tip as shown to replace fi lter. Replace fi lter whenever it becomes visibly dirty or every 2 to 3 months depending on use. Replace Sensor: Remove sensor by pulling out of socket. Install the new sensor by aligning the notch in sensor cover with the raised keyway on the sensor socket holder.(see fi...
  • Page 8: Frequently Asked Questions

    FREQUENTLY ASKED QUESTIONS Q: How does the Prowler sensor compare to heated sensor leak detec- tors? A: Besides having superior sensitivity especially to the newer HFC re- frigerants, the Prowler sensor also operates at a lower temperature than heated sensors. This is an advantage because it draws less current so it does not require the use of rechargeable batteries.
  • Page 9 Q: Will the Prowler alarm when entering a work area contaminated with refrigerant? A: Yes. Nevertheless, you must always turn on the Prowler outside of the work area (in clean air) and allow it to complete the warm up cycle before entering an area where a large leak is suspected.
  • Page 10 small hole in the top of the Vile. The beep rate should increase and the Leak Size Bar graph should display a minimum of three bars. The detector will calibrate itself to the Leak Test Vial if the sensor is held static close to the small hole in the cap and will not alarm again until it is moved away and allowed to reset.
  • Page 11 PROWLER SPECIFICATIONS Model #: LD 5000 Name: PROWLER Leak Detector, Refrigerant Gas Sensitivity: 0.025 oz/yr R-22, 0.05 oz/yr R-134a, 0.0125 oz/yr R-1234yf, 0.05 oz/yr R-410A, 0.05 oz/yr R-404A, 0.05 oz/yr R-407A, 0.05 oz/yr R-427A Sensor Life: > 10 years (normal use) Response Time: Instantaneous Power Supply:...
  • Page 12: Replacement Parts

    Carrying case LD-CS WARRANTY The PROWLER LD 5000 Refrigerant Gas Leak Detector is warranted to be free of defects in materials and workmanship for a period of two years from the date of purchase. This warranty applies to all repairable instru- ments that have not been tampered with or damaged through improper use including unauthorized opening of the unit.