FiDUS MVPS800 Series Quick Start Manual

Advertisement

Quick Links

MVPS800
800 Watts
5 x 8.5" Footprint, 1.61" for 1U installation
Latest medical approvals IEC 60601-1 (3.1) IEC 60601-1-2 (4th)
Up to 3 units load share for higher powers
Peak of 1000W for 500mS
EN55011 Level B conducted & radiated
3 Year warranty
The MVPS800 series of low profile, medically approved AC-DC power modules offer 300-800W in a
5" x 8.5" package conforming to the latest IEC60601-1 3.1 and IEC60601-1-2 4th ed standards. The
units are fully featured including 5V 1.5A auxiliary output and low standby power of 3W. The units are
body floating (BF) rated for applied part applications. They have a wide operating temperature of –40
to 70°C, in a range of voltages from 12V to 58V. All units come with a FiDUS 3 year warranty.
Models & Ratings
(1)
Model Number
MVPS800-1012
MVPS800-1015
MVPS800-1024
MVPS800-1030
MVPS800-1048
MVPS800-1058
Notes
1. For slotted cover change
0
above for S, for solid cover version change
2. Combined output power is main DC output + fan output 12V / 500mA max
3. 1000W overload for 500mS for 30V 48V and 58V only, not field configurable.

Key specifications

Parameter
AC Input range
Operating temperature
Efficiency
Dimensions
1
Series
Output
(2)
U Channel
Power
Voltage
Convection
180-400W
12V
225-500W
15V
360-800W
24V
360-800W
30V
360-800W
48V
360-800W
58V
Minimum
Typical
85
-40
120VAC 88% and 240VAC 93% typical
5 x 8.5 x 1.61" (127 x 216 x 40.9mm)
EN55011 Level B conducted and radiated with king core K5B RC 25x12x15-M on input. EN61000-3 and EN61000-4, harmonics,
flicker, Surge, EFT, ESD, conducted and radiated immunity IEC 60601-1-2 4th Ed
EN60601-1, IEC6061-1 (ed3), ANSI/AMMI ES 60601-1, CSA C22.2 No 60601-1
www.fiduspower.com
U Channel
Slotted Cover
with 300 LFM
Convection
25A
33.33A
25A
33.33A
25A
33.33A
20A
26.66A
12.5A
16.66A
10.34A
13.78A
0
above for
T
Maximum
Units
264
VAC
70
Dimensions:
5 x 8.5 x 1.61" (127 x 216 x 40.9mm)
Output Current
Slotted Cover
with 300 LFM
17.5A
31.25A
17.5A
31.25A
17.5A
31.25A
14A
25A
8.75A
15.625A
7.25A
12.93A
Notes & Conditions
Derate from 100% at 120VAC to 70% at 85VAC
°C
See derating curve p3.
Solid Cover
Solid Cover
Convection
with 300 LFM
15A
31.25A
15A
31.25A
15A
31.25A
12A
25A
7.5A
15.625A
6.2A
12.93A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MVPS800 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for FiDUS MVPS800 Series

  • Page 1 (BF) rated for applied part applications. They have a wide operating temperature of –40 5 x 8.5 x 1.61” (127 x 216 x 40.9mm) to 70°C, in a range of voltages from 12V to 58V. All units come with a FiDUS 3 year warranty. Models & Ratings...
  • Page 2 ULP275 WLP350 VPS1000 VPS1000 VPS800 MVPS800 Series Series Series Series Series Series Input Parameter Minimum Typical Maximum Units Notes & Conditions Input voltage Derate from 100% at 120VAC to 70% at 85VAC Input frequency EN61000-3-2 class D compliant, at full load. 0.98 at Power factor 0.95 0.98...
  • Page 3 ULP275 WLP350 VPS800 MVPS800 Series Series Series Series Power Derating Curve 12V Power Derating Curve 15V Power Derating Curve Others U Channel Slotted cover Solid cover 20 40 60 -40 -20 20 40 60 -40 -20 20 40 60 -40 -20 Temperature (ᵒC) Temperature (ᵒC) Temperature (ᵒC)
  • Page 4 ULP275 ULP275 WLP350 VPS1000 VPS800 MVPS800 Series Series Series Series Series Series AC Power Derating Curve Application notes Signals Power Good: TTL output activated at 90% of Vout. Delay between 100 and 500mS At least 1mS before Vout falls below 90% TTL signal switches low Remote Sense: Compensation for 200mV voltage drop on cable runs Remote on/off: Unit comes pre-configured with pin 6 &...
  • Page 5 ULP275 ULP275 WLP350 MVPS600 VPS800 MVPS800 Series Series Series Series Series Series Mechanical Details J1: Input Connector Pin Connections Function U Channel Line Neutral Earth J2: Output Connector Pin Connections Function Slotted cover +Vout -Vout J3: I/O Connector Pin Connections Function +5V 1.5A Solid cover...
  • Page 6 Then consider the impact of operational time, load and temperature profile to estimate a more realistic lifetime for your PSU. Also, many FiDUS power supplies offer a Peak Power rating to provide for customers with pulsing loads. When using a peak power capability customers must consider: 1) Peak duration rating: the maximum length of time the peak can be drawn for 2) Duty cycle: the frequency with which the peak can be drawn.

This manual is also suitable for:

Mvps800-1012Mvps800-1015Mvps800-1024Mvps800-1030Mvps800-1048Mvps800-1058

Table of Contents