5. SET UP
5.1.
ACCESSORIES
5.1.1.
To fit the battery for the remote operation via the gun handle, fit the supplied battery (CR2450/3V) into the compartment on the top
surface of the gun. Carefully prise the lid open using a wide bladed screwdriver or similar tool. Replace lid when battery is fitted.
5.1.2.
Fix the gun saddle, gun holder and power cable hook to the unit (fig.1) using the supplied fixings.
5.2.
CONNECTING THE WATER SUPPLY
5.2.1.
Use a reinforced hose pipe with an internal diameter of 1/2" and connect to the mains water supply. Before attaching the hose to the
pressure washer, flush the hose through with some clean water to remove any foreign matter from within the hose.
5.2.2.
Connect the water inlet connector (fig.1.9) to the inlet on the front of the machine (fig.1.10) ensuring that the internal filter is present.
5.2.3.
Connect the water supply hose to the connector.
Hose Release
Hose connection
fig.2
5.3.
CONNECTING THE HIGH PRESSURE HOSE
5.4.
Insert the high pressure hose into the inlet on the underside of the trigger housing (fig.2). To disconnect the hose, depress the button in
front of the connection point and withdraw the connector. The PW2400 is pre-connected to the unit via the inside of the hose storage reel.
5.5.
ASSEMBLING THE LANCE AND NOZZLE
5.5.1.
Push the lance nozzle into the gun body and fasten in place by twisting it 90
5.5.2.
Depress the button on the lance head and insert the nozzle ensuring alignment of the groove in the lance head (fig.3).
WARNING! Ensure the nozzle is locked into position, failure to ensure this could result in the nozzle being ejected under high pressure
when operating the gun.
5.6.
CONNECTING TO THE MAINS ELECTRICAL SUPPLY
WARNING! Ensure the On/Off switch (fig.1.13) is in the 'Off' position.
5.6.1.
Use an RCD plugged into a 13A mains socket (see Section 1.1 Electrical Safety).
5.7.
WIRELESS PAIRING
5.7.1.
To enter pairing, depress and hold Level 1 and Level 3 buttons (fig.4) for 2 seconds. The indicator light (fig.4.E) will flash. To exit paring,
depress and hold the Level 1 button for 2 seconds.
5.7.2.
To pair the gun to the unit, depress the multi function button (fig.3) for 5 seconds. The indicator light will flash and when the units are
paired, the indicator light will go off.
5.7.3.
Once paired, the current operating level light will illuminate. If pairing fails the unit will exit pairing mode after 10 seconds.
NOTE: Once paired, the unit can only be operated by the remote control.
I
K
fig.3
© Jack Sealey Limited
Item
H - Level 1 Indicator
I - Level 2 Indicator
J - Level 3 Indicator
K - Status Indicator
H
J
L - Multi-function Button
L
Original Language Version
Low Pressure
High Pressure
fig.3
0
ensuring that the connection is tight.
Function
After switching the level on the remote control, the
Indicator shows the currently set level, and then the
indicator goes out.
1. The status indicator flashes quickly in pairing
mode.
2. The status indicator is off when successfully
paired with the host.
3. The status indicator flashes 3 times slowly
when the battery is low, indicating that the battery
needs to be replaced.
1. Switch working level button
2. Wireless pairing mode button
3. Exit wireless pairing mode button
PW2400