4.2 RainsaverMK4E installation.
The RainsaverMK4E must be mounted in the horizontal position, and the RainsaverMK4E
power socket to accept the pump power lead must hang in the down position.
The RainsaverMK4E can be Wall mounted or Pump Mounted i.e. mounted directly onto a pressure
pump outlet. The steel wall mounting bracket, which is connected to your RainsaverMK4E, can be
rotated to allow the unit to be wall mounted in either direction, or may be removed for pump
mounting.
4.21 Wall Mounting:
The RainsaverMK4E can be mounted outdoors on a flat vertical surface.
The RainsaverMK4E can be mounted with the mains inlet pointing in either direction.
Pressure tank pre-charge pressure should be 65% of pump maximum pressure.
Wall Mounting Instructions:
To reverse the mounting direction, so that "Mains" inlet will be on the left side and
-
"House" outlet on the right, follow the first steps of Pump Mounting Instructions below to
remove and reverse the mounting bracket. Then continue:-
-
Remove the RainsaverMK4E lid by unscrewing the 4 Phillips head screws
-
Hold the RainsaverMK4E in the desired position and mark the screw centres through the
keyhole slots in the mounting bracket. Return the RainsaverMK4E to the box.
-
Drill and insert mounting hardware into the mounting surface (wall). Insert screws leaving
a few millimetres under the head to allow insertion of the mounting bracket
-
Mount the RainsaverMK4E onto the screws through the keyhole slots in the mounting
bracket. Tighten screws to secure the bracket to the wall
-
Replace the RainsaverMK4E lid and re-tighten the four (4) lid screws.