5. Sound Emissions.
The RainsaverMK4E is virtually silent but may emit noises associated with the flow of water through
the unit.
In any case, the pump, which is connected to the RainsaverMK4E, may emit sound levels, which
may inconvenience you or your neighbours, or may operate during normal sleeping hours, which may
be prohibited by local government regulations. If this is the case, your RainsaverMK3 can be
switched off during the night or may be operated from a time clock. Your RainsaverMK4E will
automatically supply your house with Mains water supply while the pump is inactive.
6. Maintenance.
Ensure that water flowing through the Rainsaver MK4E is as free from dirt and foreign matter as
conditions allow.
Ease of accessibility will aid any maintenance and reduce any servicing costs if required.
Periodically inspect the rainwater tank inlet strainer and the first flush device. Periodically inspect
filters downstream and strainers if fitted upstream from the Bianco Rainsaver MK4E every 6 months
depending on water quality and usage.
Operate the Rainsaver on mains regularly or at least once a month by turning the power off to the
RainsaverMK4E.
7. Trouble shooting.
Consult the manuals supplied with the water pump and its controller if fitted in addition to the
following guide.
1.
Mains flow is not available or low when Pump is switched off or not operating.
a. Isolation valve, if fitted, is not open.
b. Debris has jammed the mains inlet check valve closed.
c. External Inlet strainer / filter, if fitted, are blocked.
2.
Pump flow is not available or low when pump is operating through Bianco Rainsaver
MK4E.
a. Pump has lost its prime.
b. Isolation valve, if fitted, is not open.
c. Debris has jammed the pump inlet check valve closed, or has blocked the check
valve.
d. External Inlet strainer / filter, if fitted, is blocked.
3.
Pump does not start.
a. Rainwater tank is empty.
b. Power supply is off.
c. Float switch is not installed correctly.
d. Pump controller is not installed correctly or jammed with debris.
e. Pump has a fault.
4.
Pump does not stop.
a. Leak in plumbing.
b. Pump controller is not installed correctly or jammed with debris
c. Float switch is not installed correctly.
Note*
Should there be a pump failure, mains back up is achieved by turning the RainsaverMK4E off at
the power point.
For after sales service please contact White International Customer Service: 1300 783 601.