Lab.gruppen fP Series FP 3400 User Manual page 10

Lab.gruppen fp series fp 3400: user guide
Hide thumbs Also See for fP Series FP 3400:
Table of Contents

Advertisement

TM
MLS
settings can be different for each channel, and a variety of combinations can be achieved – see
table 2. Table 2 provides the simplest way to find the best MLS
no risk to damage the amplifier since it is very well protected (even down to 0.3 ohms). The fP 3400
amplifier is a power converter, and by selecting MLS
watts power.
MLS switches on rear panel
RKQKN= ^=éê~ÅíáÅ~ä=ï~ó=íç=ÑáåÇ=óçìê=jip
ëÉííáåÖë=
1. Check if the loudspeaker can take the
amp's maximum output power
(generally, twice the RMS power
handling should be okay).
2. If the loudspeaker can handle the amp's
maximum output power, leave MLS at
its highest position (0dB).
3. If the loudspeaker is specified at a
lower power handling, reduce the
amp's output power by changing MLS
to a matching lower value (-2dB, or
-4dB, or -5dB).
4. Try the setup with a musical signal. If
the amp runs into thermal protection, or
into current limiting (audible as
distortion, or as "clicks" from a cone
driver/woofer), reduce the amp's output
power by changing MLS to a lower
value.
If you reduce the amp's output power by choosing
lower MLS values, you only reduce the maximum
output voltage. In fact, you will get more current
headroom for low impedance loads. The amp runs
at higher efficiency, and the risk for going into
thermal protection is significantly lower.
i~ÄKÖêìééÉå==
=
rëÉê=j~åì~ä===Ñm=PQMM======sÉêëáçå=NKN========OMMPJNMJMO=
qj
=
=
=
TM
settings for your application. There is
TM
positions you are allocating a portion of the 3400
Type of mode
Conventional mode
High voltage mode
Load matching
Power sharing
Limited power
Bi-amp mode
=
=
Power/Impedance
Ch.A
1100/8 Conventional mode
1500/4
1700/2
94Vrms High voltage mode
1100/8
520/16
1100/8 Load matching
1500/4
700/8
1700/2 Power sharing
1700/2
1700/2
1200/2 Limited power
1400/2
750/4
1700/2 Bi-amp mode
1500/4
1100/8
1700/4
========================
V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp 3400