3.1.4 Connection of Power Supply

Pin Name
Details
Power supply positive connection.
+VDC
iCS-17xx:20-36VDC
iCS-23xx and iCS-24xx: 20-50 VDC
GND
Power supply ground connection.
Notes: It is recommended that power voltage of all integrated motors are 24VDC, otherwise if the motor is too hot, it is easy to
transfer heat to the drive, thus damaging the drive.
3.2 Connector P2 – Tuning Port
The P2 connector in Figure 2 is a communication port for Leadshine software connection. It is just used to modify parameters,
not for equipment control because neither precision nor stability is sufficient. If you need a Modbus-RS485 control, please use
a Leadshine iCS-RS series integrated stepper motor.The interface definition is as follows:

3.3 LED Light Indication

There are two LED lights for iCS series motor, one is red and another is green. The GREEN one is the power indicator which
will be always on generally. The RED one is a protection indicator. It is off always when a iCS-17xx operates normally, but will
flash 1, 2 or 7 times in a 5-second period when error protection is enabled. Different number of flashes indicates different
protection types.
Blink
Sequence wave of red LED
time(s)
0.2S
1
0.3S
0.2S
2
0.2S
0.3S
7
Always
When above protections are active, the motor shaft will be free and the red LED blinks. Reset the drive by repowering it to
make it function properly after removing above problems.

4. DIP Switch Configurations

The iCS series has a row of DIP switches, but the iCS17xx and iCS-23xx DIP switches are a bit different, as follows
Figure5: RS232 Tuning Port
5S
Over-current
5S
Over-voltage
5S
Position following
error
PCB
-
burned out
iCS Series Integrated Closed Loop Stepper Motor
Description
Turn off the power immediately.
a) Check wiring is short-circuited or not;
b) Check motor is short-circuited or not.
Turn off the power immediately.
a) Check if the power voltage is higher
than 90VDC
a) The value of position following error
is set too small.
b) Motor torque is not enough, or motor
speed is too high.
board
is
Contact after-sale
a) Power supply connection is wrong
5
Trouble shooting