Download Print this page
Griven Parade L1 User Manual

Griven Parade L1 User Manual

Advertisement

Quick Links

Parade
L1 - L2- L3 - L4
Code
Power consumption
Consumo di energia
Nominal current
Corrente nominale
Power supply
Alimentazione elettrica
Inrush current
Corrente di spunto
Power factor
Fattore di potenza
Electrical class
Classe elettrica
Weight / Peso
Operating temperature
Temp. funzionamento
IP rating / Grado IP
IK rating / Grado IK
Dimensions / Dimensioni
Parade L1
Griven S.r.l. - Via Bulgaria, 16
46042 Castel Goffredo
Mantova - Italy
User Manual
Rev. 4.0
Date: 29/09/2022
Parade L1
AL5060 - AL5061 (PE)
20W (RN) 19W (DW)
19W (W)
0.1A (RN) 0.1A (DW)
0.1A (W) @230Vac
23.42 A @240VAC, 25°C
cos.φ= 0.87
2.1 Kg
318 mm
[12.5"]
610 mm [24"]
Parade L2
914 mm [36"]
Parade L3
1219 mm [48"]
Parade L4
Tel. +39.0376.779483
E-mail: sales@griven.com
Web: www.griven.com
Parade L2
AL5065 - AL5066 (PE)
38W (RN) 38W (DW)
37W (W)
0.17A (RN) 0.17A (DW)
0.17A (W) @230Vac
220-240VAC 50/60Hz
cos.φ= 0.94
I
3.1 Kg
-40°C to +50°C ( -40°F to 122°F )
IP67
IK09
© Copyright Griven 2020 - GRIVEN S.r.l. is continuously
developing and improving all its products.
We reserve the right to change specifications without
prior notification
Parade L3
AL5070 - AL5071 (PE)
58W (RN) 57W (DW)
56W (W)
0.26A (RN) 0.26A (DW)
0.25A (W) @230Vac
27.5 A @240VAC, 25°C
cos.φ= 0.95
4.4 Kg
76 mm
[3"]
551091
Parade L4
AL5075 - AL5076 (PE)
79W (RN) 76W (DW)
75W (W)
0.35A (RN) 0.34A (DW)
0.34A (W) @230Vac
cos.φ= 0.97
5.6 Kg
page 1 of 8

Advertisement

loading

Summary of Contents for Griven Parade L1

  • Page 1 914 mm [36”] Parade L3 1219 mm [48”] Parade L4 page 1 of 8 © Copyright Griven 2020 - GRIVEN S.r.l. is continuously Griven S.r.l. - Via Bulgaria, 16 Tel. +39.0376.779483 developing and improving all its products. E-mail: sales@griven.com 46042 Castel Goffredo We reserve the right to change specifications without...
  • Page 2 Important notices - Avvisi importanti - This product must be installed in accordance with applicable national and local - Questo prodotto deve essere installato secondo le normative locali, da personale electrical and construction codes by a person familiar with the construction and specializzato.
  • Page 3 Connection - Connessione “C” Type cable ( Monocable + connectors ) POWER + DMX OUT POWER + DMX OUT A=DMX- B=DMX+ C=common 3=GND POWER + DMX IN POWER + DMX IN “M” Type cable (Monocable without connectors - DMX) Blue= N (Neutral) Yellow/Green=GND Brown=L (Line) RED= DMX +...
  • Page 4: Installation - Installazione

    Installation - Installazione Ø6 L1 = from 90 to 319 L2 = from 90 to 610 L3 = from 90 to 915 L4 = from 90 to 1220 Size 8 (ISO) socked Hex key -90° Size 10 (ISO) Hex key Size 10 (ISO) Hex key Size 4 (ISO)
  • Page 5 IR Remote Control operations / Operazioni del telecomando IR The fixture must be configured only by using AL1321 IR remote control ( sold separately ) or via any DMX-RDM compatible controller. FLASH 5’ inactivity = Automatic LOGIN LOGOUT = OK FLASH FLASH Enter the“IR”...
  • Page 6: Dmx Chart

    LEDs at full intensity). 0→100% Dimmer 0-255 • Manufacturer: it displays the name of the manufacturer 0-100% Red 0-255 (Griven). 0-100% Red fine 0-255 • Model description: it displays the fixture’s model. • Software version description: it displays the current version 0-100% Green 0-255 of the firmware.
  • Page 7 DALI supported commands Command # Description Up (Fade rate) Down (Fade rate) Step Up ( Increment arc power level ) Step Down ( Decrement arc power level ) Recall MAX level Recall MIN level Step down and off ( Decrement arc power level if at min level turn down ) 16...31 Go to scene 0...15 Reset ( DALI factory default parameters )
  • Page 8 Configuration examples / Esempi di configurazioni Copyright © 2020, GRIVEN S.r.l World Lighting Challenge - www.griven.com Use a DMX repeater on each 32nd 10 A Max. the total DMX LINE length exceeds daisy chain 1000 ft (300m) 10 A Use a DMX repeater on each 32nd Max.

This manual is also suitable for: