6.1. HDBaseT Link (RJ45) Connection

This device is specified to operate with Category cables for communication between
the transmitter and receiver. The transmission path may include a maximum of two
keystones and two patch cables, as long as the total length does not exceed 330' for
Cat5e/6/6a/7 when used with an HDBaseT transmitter.
TIA/EIA Standard 568-B (Gold Pins Facing Up)
Pin 1 White/Orange
Pin 2 Orange
Pin 3 White/Green
Pin 4 Blue

6.2. IR Control Connections

Bidirectional IR signals can be transmitted between the receiver and an HDBaseT
transmitter through category cable. The IR signal can be generated either from a
powered receiver or from a control system. The following section describes these
two use cases.
CAUTION: Pinout configurations for IR receivers and control systems vary.
Before connecting to this input, review this section carefully in order to match the
pinouts for the device.
Pin 5 White/Blue
Pin 6 Green
Pin 7 White/Brown
Pin 8 Brown
FIGURE 3: RJ45 Connections