Check Valve Status
To check if the valve is open or closed press the OPEN or CLOSE button
momentarily.
When controlled by the thermostat:
A rapid single
Red
flash indicates the valve is closed
A rapid single
Green
flash indicates the valve is open
When in Manual mode:
Two rapid
Red
flashes indicates the valve is closed
Two rapid
Green
flashes indicates the valve is open
Manually open or close the valve
To manually open or close the valve.
1.
Unlock the TRV -
Press RADIO + CLOSE button for 3 seconds
2.
Open - Press the OPEN button for 3+ seconds, LED flashes
3.
Close – Press the CLOSE button for 3+ seconds, LED
The valve will remain in the commanded position until:
Manually changed by pressing OPEN or CLOSE button for 3+ seconds
Returned to Automatic mode by briefly pressing the RADIO button
Room temperature falls below the Frost Protection set point of 41°F
(5°C)
Frost Protection
When the TRV has been manually closed, Frost Protection is automatically
enabled. If the room temperature falls below 41°F (5°C), the TRV will control
to the Frost Protection set point. When controlled by the thermostat, the
TRV responds to the thermostat's Frost Protection set point.
Lime Scale Protection
The TRV has a lime-scale protection feature where if the valve has not moved
for 14-days, the TRV will automatically stroke the valve open and closed.
This function will attempt to prevent the valve from sticking due to scale
buildup on the valve assembly.
Factory Reset to default settings
The TRV can be reset to default settings and network, pairing, and valve
calibration information cleared if the device is not operating as expected.
1.
Unlock the TRV -
Press RADIO + CLOSE button for 3 seconds
2.
To factory reset, press OPEN, CLOSE and RADIO buttons for 3+ seconds: LED
flashes
Orange
once
3.
Remove the side battery door
4.
Remove at least 1 battery for approximately 5 seconds
5.
Replace battery(s)
6.
Replace side battery door
The TRV will go through the initialization process described above then the
LED will flash
Green
(0.5s on/0.5s off)
Auto Adaptation
The TRV will reinitiate the initialization and Adaptation process where it
calibrates itself to the valve, each time the batteries are replaced.
Configuration, network, and pairing settings will be retained – unless it has
been Factory Reset.
Manual Adaptation
If you suspect that the TRV is not calibrated properly to the valve, you can
remove and replace the batteries, or force the TRV to initiate the
Adaptation process
1.
Unlock the TRV -
Press RADIO + CLOSE button for 3 seconds
2.
Hold the Radio + OPEN buttons for 3+ Seconds: LED flashes
TRV will open the valve
3.
Ensure the TRV mounting ring is finger-tight on the valve
4.
Press any button to start the Adaptation process
Fail-Safe mode
The TRV will open to 25% as a Fail-Safe mode to provide some level of heat,
if hot water/steam is available if:
The TRV loses or fails to Join the network or Pair with the thermostat
TRV receives no command from thermostat for 1+ hours
Low battery
Temperature sensor malfunction
When in the Fail-Safe mode the TRV can be manually opened or closed
Green
flashes
Red
to indicate it is in the Joining mode.
Red
Quick Functions
To do this...
Unlock the buttons
Lock the buttons
Manually open the
valve
Manually close the
valve
Return TRV to
automatic mode
Redo Adaptation to
valve
Restore factory default
settings
Join Network & Pair
with thermostat
Leave the network (if
already Joined)
Various LED States
When...
Batteries inserted or
after reset
Unit adapting
(calibrating) to the
valve
Unit has joined the
network but has not
paired to thermostat
Unit paired to
thermostat and in
auto mode
Leaving network
Identifying the
network
When OPEN or
CLOSE button is
pressed
momentarily
Low battery
and the
Error installing
SALUS North America, Inc.
For Technical Support:
support@salusinc.com
1-885-557-2587
Please visit
www.salusinc.com
SMC-QG- AVA10M30RF-EN-202111v1
Copyright © SALUS North America, Inc. 2021
Press the...
Press RADIO + CLOSE buttons together for 3 seconds,
LED flashes
Green
once
Press RADIO + CLOSE buttons together for 3 seconds,
LED flashes
Red
once
Unlock, press OPEN button for 3 seconds, LED flashes
Green
once
Unlock, press CLOSE button for 3 seconds,
LED flashes
Red
once
Short press RADIO button, LED flashes
Unlock, press RADIO + OPEN buttons together for 3
seconds. LED flashes
Red
as actuator opens.
Unlock, press OPEN + RADIO + CLOSE buttons
together for 3 seconds LED flashes
remove and replace batteries
Unlock, press RADIO button for 10 seconds until LED
begins to continuously blink
Green
Unlock, press RADIO button for 10 seconds. LED
flashes
Orange
once, blinks
Green
The LEDs...
Flash rapidly
Red
than
Green
to indicate the
software version
Steady
Red
as TRV opens valve
Flash
Green
as TRV closes the valve
Flash
Orange
as TRV reopens the valve
No LED as the TRV steps the valve closed
Flash
Orange
(0.5s on/0.5s off)
No LED
Orange
for one second, then flash
on/0.5s off)
Flashes
Green
for up to 10 minutes
Flashes
Green
once after short press on open or
close button in Auto mode
Flashes
Red
once after short press on open or
close button in Auto mode
Flashes
Green
twice after short press on open or
close button when in Manual Open
Flashes
Red
twice after short press on open or
close button when in Manual Close
Flashes
Red
three times quickly every 10 seconds
As the battery continues to drain the frequency
will be decreased
Before the batteries drain completely, the TRV
will move to the Fail-Safe position (25% open)
Green
and
Red
flash alternately