American Standard YSC036A Installation, Operation And Maintenance Manual page 17

Packaged gas/electric 3-10 ton
Hide thumbs Also See for YSC036A:
Table of Contents

Advertisement

Installation
Table 1.
Typical unit weights and point
loading data (continued)
Unit Model
YHC036E1, E3, E4
YHC048A1*(M,Y)
YHC048A1*(H,Z)
YHC043A(3,4,W)*(L,M,X,Y)
YHC048A(3,4,W)*(L,M,X,Y)
YHC043A(3,4,W)*(H,Z)
YHC048A(3,4,W)*(H,Z)
YHC048E1, E3, E4
YHC060A1*(L,M)
YHC060A1*(H,Z)
YHC060A(3,4,W)*(L,M,X,Y)
YHC063A(3,4,W)*(L,M,X,Y)
YHC060A(3,4,W)*(H,Z)
YHC063A(3,4,W)*(H,Z)
YHC060E1, E3, E4
YHC072A(3,4,W)*(L,X)
YHC072A(3,4,W)*(M,Y)
YHC072A(3,4,W)*(H,Z)
YHC092A(3,4,W)*(L,X)
YHC092A(3,4,W)*(M,Y)
YHC092A(3,4,W)*(H,Z)
YHC102A(3,4,W)*(L,X)
YHC102A(3,4,W)*(M,Y)
YHC102A(3,4,W)*(H,Z)
YHC120A(3,4,W)*(L,X)
YHC120A(3,4,W)*(M,Y)
YHC120A(3,4,W) *(H,Z)
Figure 7.
Rigging and center of gravity
RT-SVX21F-EN
Net
Corner Wt. (lbs)
Weight
(lbs)
A
B
C
D
544
127
103
204 110
511
157
126
108 121
539
166
133
114 126
577
167
144
139 127
511
157
126
108 121
577
167
144
139 127
539
166
133
114 126
790
173
145
266 141
562
176
137
116 133
574
179
140
119 136
550
175
133
110 131
612
180
151
144 137
561
178
137
113 134
561
178
137
113 134
748
222
92
345
89
756
245
193
137 181
768
248
197
140 183
772
249
198
141 184
907
302
238
161 207
911
303
239
162 208
923
306
243
165 210
942
306
247
171 217
946
307
248
172 218
957
310
252
175 220
1035
336
269
191 240
1047
339
272
194 242
1060
342
277
197 245
Table 2.
Center of
Gravity (In.)
Option/Accessory
Description
Length Width
Economizer
39
26
Motorized Damper
32
20
Manual Damper
32
20
Barometric Relief
32
20
Power Exhaust
32
20
Oversize Motor
32
20
Belt Drive Motor
32
20
(3 phase only)
40
25
Hinged Access
31
20
Hail Guard
32
20
Through the Base:
31
19
Electrical
31
19
Through the Base :
Gas
31
19
Unit Disconnect
31
19
Switch
41
24
Unit Circuit Breaker
39
22
Conv. Outlet:
Unpowered
39
22
Conv. Outlet:
39
22
Powered
39
22
TCI, LCI
39
22
NOVAR
39
22
HPC
39
22
Frostat
39
22
Crankcase Heater
40
22
Smoke Detector,
39
22
Return
39
22
Smoke Detector,
Supply
40
22
Clogged Filter
Switch
Fan Fail Switch
Discharge Air Tube
Roofcurb
LP Conversion Kit
All Zone Sensors
Hard Start Kit
Reheat Coil
Stainless Steel Heat
Exchanger
Typical accessory weights
Weight - Net lbs
YHC033
YH/
, 043,
YSC036-
063
060
26
26
20
20
16
16
7
7
N/A
N/A
5
5
Standard
31
10
10
12
12
8
8
5
5
5
5
5
5
2
2
38
38
1
1
8
8
1
1
1
1
1
1
7
7
5
5
1
1
1
1
3
3
70
70
3
3
3
3
3
3
15
15
5
5
YH/
YSC072-
120
36
30
26
10
80
8
Standard
12
20
13
5
5
5
2
38
1
8
1
1
1
7
5
1
1
3
115
3
1
N/A
25
10
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents