Alignments - Philips PICO 19HFL3232D/10 Service Manual

Hide thumbs Also See for PICO 19HFL3232D/10:
Table of Contents

Advertisement

6. Alignments

Index of this chapter:
6.1 General Alignment Conditions
6.2 Hardware Alignments
6.3 YPbPr Mode display adjustment
6.4 PC mode display adjustment
6.5 Option Settings
6.6 Serial Number Definition
Note: The Service Alignment Mode (SAM) are described in
chapter
5. Service Modes, Error Codes, and Fault
Menu navigation is done with the CURSOR UP, DOWN, LEFT
or RIGHT keys of the remote control transmitter.
6.1
General Alignment Conditions
Perform all electrical adjustments under the following
conditions:
Power supply voltage: 195 - 264 V
Connect the set to the mains via an isolation transformer
with low internal resistance.
Allow the set to warm up for approximately 15 minutes.
Measure voltages and waveforms in relation to correct
ground.
Caution: It is not allowed to use heatsinks as ground.
Test probe: R
> 10 MΩ, C
i
Use an isolated trimmer/screwdriver to perform
alignments.
6.2
Hardware Alignments
Not applicable.
6.3
YPbPr Mode display adjustment
6.3.1
General set-up
Equipment Requirements:
Minolta CS-200 or equivalent Colour analyser, Quantum Data
Pattern Generator 802G, 802BT or equivalent instrument.
Input requirements:
Input Signal Type: YPbPr signal
1080i mode, TVBar100 pattern by 802G or 802BT.
Select Picture mode to User mode and check the x, y data.
Input Signal Strength:
1 V
for Y signal; 700 mV
pp
Input Injection Point:
YPbPr (RAC jack)
6.3.2
Alignment method
Quantum Data Pattern Generator 802G or 802BT. Apply 1080i,
and the pattern TVBAR100 with a Quantum colour analyser.
Initial Set-up:
1. Select source as "EXT2".
2. Set Smart Picture mode as "Standard" and off the
"Dynamic contrast/Dynamic backlight".
3. Apply "TVBar100" pattern with colour bar pattern by signal
generator.
4. Enter factory mode menu: press numeric keys
"062596" + INFO key (FAC mode menu).
Finding.
, 50/ 60 ± 3 Hz.
AC
< 20 pF.
i
for Pb & Pr signal
pp
Alignments
TPM5.2E LA
Alignment:
1. At SAM mode menu, select AUTO_COLOR item. Then
press "OK" key to adjust ADC_GAIN_R, ADC_GAIN_G,
ADC_GAIN_B and ADC_OFFSET_R, ADC_OFFSET_G,
ADC_OFFSET_B. Then store those values to NVM.
2. Apply 100% white pattern.
3. Set colour temperature to "NORMAL".
4. At FAC mode menu, adjust the CLR TEMP R, CLR TEMP
G, CLR TEMP B values to meet "NORMAL" colour
coordinates specification below. Then store those values to
NVM (R/G/B gain value <= 128).
5. Set colour temperature to "COOL".
6. At FAC mode menu, adjust the CLR TEMP R, CLR TEMP
G, CLR TEMP B values to meet "COOL" colour
coordinates specification below. Then store those values to
NVM (R/G/B gain value <= 128).
7. Set colour temperature to "WARM".
8. At FAC mode menu, adjust the CLR TEMP R, CLR TEMP
G, CLR TEMP B values to meet "WARM" colour
coordinates specification below. Then store those values to
NVM (R/G/B gain value <= 128).
Colour temperature Normal/Warm/Cool (x, y) co-ordinates
specification:
Table 6-1 Reading with Minolta CS-200
Picture Mode
0.287 ± 0.003
Normal (9000K)
0.276 ± 0.003
Cool (11000K)
0.313 ± 0.003
Warm (6500K)
If you have not such equipment, the below value is for your
reference.
Table 6-2 Reference value
Picture Mode
Size
Normal (9000K) 19"
22"
26"
Cool (11000K)
19"
22"
26"
Warm (6500K)
19"
22"
26"
Note:
Check Luminance:
Use Minolta CS-200 or Equivalent Colour analyser for
colour coordinates and luminance check. Then Set CS-200
receiver at the centre of the screen.
when Brightness/ Contrast / Video Contrast setting at 100
and CLR_TEMP_R / CLR_TEMP_G / CLR_TEMP_B =
128. The Luminance need arrive at
(1) 19PFL3405H or 22PFL3405H Luminance > 240 cd/m
(2) 26PFL3405H Luminance > 320 cd/m
equivalent Colour analyser need to calibration with Minolta
CS-200.
6.
EN 19
x
y
0.296 ± 0.003
0.282 ± 0.003
0.329 ± 0.003
Colour temperature
Red
Green
Blue
128
128
107
116
128
111
126
128
100
119
128
116
105
128
124
111
128
120
128
116
70
128
128
80
128
109
56
2
.
2010-Jun-25
2
.

Advertisement

Table of Contents
loading