Connecting Refrigerator To Water Supply - LG LRYDS3106 Series Owner's Manual

French door refrigerator
Hide thumbs Also See for LRYDS3106 Series:
Table of Contents

Advertisement

NOTE
• Disassembling/Assembling the Water Lines
Collet
Tube
Insert line
e
f
g
• Gently press the collet and insert the tube until
only one line shows on the tube.
Assembling the Hinge Cover
Position the hinge cover in its place. Insert and
tighten the cover screws.
Connecting Refrigerator to
Water Supply
Before Beginning
These instructions assume you have an existing
water supply connection for the refrigerator. If
necessary, call a qualified plumber to install a
water supply line for the refrigerator.
• Turn the icemaker OFF if the refrigerator will be
used before the water line is connected.
• Do not install the icemaker tubing in areas
where the ambient temperatures fall below
freezing.
WARNING
• Connect to potable water supply only.
CAUTION
• To prevent burns and product damage, only
connect the refrigerator water line to a cold
water supply.
• Wear eye protection during installation to
Water Pressure
You will need a cold water supply.
Water Pressure
Clip
h
• Models with water filter:
• Where reverse osmosis water filtration
If the water pressure from the reverse osmosis
system is less than 20 psi or 138 kPa or 1.4 kgf/cm
(takes more than 4 seconds to fill a cup of 7 oz or
198 cc capacity):
• Check to see if the sediment filter in the reverse
• Allow the storage tank on the reverse osmosis
• If the water pressure remains low, call a
• All installations must be in accordance with local
Supplies Needed
• Copper or PEX Tubing, ¼ in. outer diameter, to
• ½ in. or adjustable wrench.
• Flat-blade and Phillips screwdrivers.
• Two ¼ in. outer diameter compression nuts
prevent injury.
- 20 - 120 psi (138 - 827 kPa)
system is connected to a cold water supply:
- 40 - 60 psi minimum to reverse osmosis
2
system (2.8 kgf/cm
- 4.2 kgf/cm
2 - 3 seconds to fill a cup of 7 oz capacity)
osmosis system is blocked. Replace the filter if
necessary.
system to refill after heavy usage.
licensed, qualified plumber.
plumbing code requirements.
connect the refrigerator to the water supply. Be
sure both ends of the tubing are cut square. To
determine how much tubing you need, measure
the distance from the water valve on the back of
the refrigerator to the water supply pipe. Then,
add 8 feet (2.4 m). Be sure there is sufficient
extra tubing (about 8 feet [2.4 m] coiled into 3
turns of about 10 in. [25 cm] diameter) to allow
the refrigerator to move out from the wall after
installation.
and 2 ferrules (sleeves) to connect the copper
tubing to the shutoff valve and the refrigerator
water valve. If you are using a PEX water line kit,
INSTALLATION
21
2
, or less than
2

Hide quick links:

Advertisement

Table of Contents