This product is a tool-like handheld thermographic IR camera. It has 110,592/27,648 effective infrared pixels, laser, illuminator and 500W-pixel visible lens. It can be connected to the PC, TF card, mobile devices (IPHONE or Android devices) and HDMI display, meeting the demands of use in different occasions.
Page 3
the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.
Page 4
may cause damage to the device. following must be strictly observed: high temperature object. immediately rinse eyes with clear water, and take medical care. Manual, and comply with the charging steps and precautions. Wrong charging causes the battery to become hot, damaged, and even causes human injuries.
Page 5
Please avoid long-time contact to the overheating device. use the original battery and charging wire provided by our company. power prompt. shut down. , it indicates that the battery has been run out. The device can be launched only after being charged with an original charger for more than 10 minutes.
Contents Chapter 1 List of Items..............Chapter 2 Overview of Component..........Chapter 3 Overview of Mainframe..........A A glance at functional areas........B Gallery................ C Shortcut menu............Chapter 4 Observation..............Image mode switching..........Temperature measurement........... Electronic zooming............Chapter 5 Shooting............... Photo shooting............
Page 7
Contents Resizing of analysis object........Real-time temperature curve of object....Function analysis of moving object......Color palette switching........... Manual adjustment of brightness/contrast..... Analysis on temperature difference....... File browsing............... Picture analysis............Picture editing............Picture zoom in/out..........PDF generation............PDF printing............Video playback............Video analysis............
Page 8
Contents Center temperature cursor........Temperature measurement range......Switch of temperature unit........Switch of distance unit........... Alarm setting............High temperature alarm......... Brightness.............. Scheduled shutdown..........Scheduled sleep............ Volume..............Vibration feedback..........Automatic lens recognition........Disabling of automatic lens recognition....Temperature marker on full screen......Color of isotherms..........
Page 9
Contents Watermark setting..........Connection settings........... WIFI switch............Bluetooth..............About updates............. Program upgrade........... Firmware upgrade..........Storage space............Formatting TF card..........Data synchronization..........Restore default settings......... Chapter 7 Connection with External Devices......Port connection............Micro HDMI interface..........USB interface............Computer settings for connection to IR analysis software..............
Overview of Mainframe A A glance at functional areas Display area Gallery Enter “Real-time editing” Control area System setting Color palette Center cursor Shortcut menu button...
Overview of Mainframe B Gallery: 1. Click the [ browsing interface. Then click the selected image to enter the image editing interface. 2. Click the [Edit] button at the bottom to enter the editing area of analysis...
Overview of Mainframe C Shortcut menu: Provide shortcut operations in real-time image, mainly including IR mode switching, camera mode switching, illuminator switching, laser switching, wireless AP hotspot switching, zoom adjustment, USB real-time video. How to enter shortcut menu 1. Under real-time image state, slide up the shortcut icon [ ] at the bottom of the interface, the system would pop out the shortcut menu interface.
Page 21
Overview of Mainframe Shutter compensation: double click the real-time image area, the system will automatically conduct shutter compensation operation, and pop up a prompt message. Electronic zooming: provide 4-time electronic zooming function. USB real-time video: turn on/off the USB real-time video connections...
Chapter 4 Observation Electronic zooming Temperature measurement Image mode switching...
Page 23
Observation Image mode switching Enter the real-time video, click - IR mode, click the infrared mode button in shortcut menu several times so as to conduct multi-mode switch operations to the current image. Images can be switched among the following four modes: A.
Observation Temperature measurement 1. Under the real-time image state, click the shortcut menu [ ] at the bottom right of the screen. 2. Click the “Material” button in the parameter menu, select the corresponding emissivity parameter based on the measured target, and then click the “Target distance”...
Page 25
Observation 3. Align the center cursor with the measured object. Then manually rotate the lens focusing ring counterclockwise or clockwise to adjust the focal length (The electric focusing model can automatically focus via the left or right target in the center of the screen as much as possible, and keep the target relatively static).
Photo shooting Under the real-time image state, press the [Shoot] button on the device to freeze or shoot the current scene, and save the image. Enter system settings –shooting setting to directly set key function to shooting, then you can achieve one-click photo shooting. 1.
Photo shooting 3. Under the interface frozen state, press the [shoot] button again to save the frozen image automatically. Adding annotation browsing directory. 2. Double click the touch screen to select the original image that needs to be 3. After entering the single image browsing interface successfully, select the remark icon [ ] at the bottom of the interface, and then enter the remarked operation menu.
Photo shooting Adding text annotation 1. Select the adding text annotation [T] button. 2. Enter the input area of the annotation text and enter valid annotation information, such as XXXX. 3. After text information input is completed, press [Return] button. The system will pop up the text annotation saving dialog box, click [OK] to save it.
Page 31
Photo shooting 2. The bottom button function as brush, eraser and color selector, the user 3. From left to right, the four function buttons are undo, last step, restore and save. The user can conduct operations to the image with these buttons.
Video Recording 1. Before shooting, aim at the target, and make the target image clearly manually or automatically. (only some models support automatic focusing) 2. Click shortcut menu button at the bottom, the current interface will immediately switch to recording mode after clicking the camera mode. 3.
Real-time analysis Adding /removing analysis object 1. In the real-time image state, click the rightmost button [ ] of the shortcut menu, you can enter the adding analysis object menu interface, as shown below 2. It provides temperature measurement of various analysis object, such as lines, rectangles, circles and spots.
Real-time analysis Resizing analysis object Real-time temperature curve of object Add linetype analysis objects or select existing linetype analysis objects. Synchronous real-time display of temperature information from 30 points is supported.
Real-time analysis Function analysis of moving object 1. Click button [ ] to enter the interface for adding analysis objects. 2. Select the analysis objects to be added (such as a rectangular analysis object).
Real-time analysis 3. When the analysis objects are selected, move the objects by the “up”, “down”, be refreshed synchronously. Color palette switching 1. Enter the main interface, and click the area of color ring at right of the screen. The system will pop out the options of color ring, including white heat, lava, iron red, rainbow 1, arctic, hot iron, medical, tint and black hot;...
Real-time analysis Manual adjustment of brightness/contrast 1. Under real-time menu state, double-click the maximum temperature or the minimum temperature at the right side of the screen directly. 2. The maximum and the minimum temperature of the color palette on real-time video frame are locked.
Real-time analysis Analysis on temperature difference After adding at least two analysis objects, click the button for temperature difference mode [ ]. It is required to manually select two analysis objects so as to calculate the temperature difference. Before analysis on After analysis on temperature difference temperature difference...
File browsing 1. Local pictures and videos: under real-time menu state, click the gallery button [ storage. 2. Pictures and videos in TF card: under real-time menu state, click the and select the SD card tag at lower right corner. The system will automatically...
Picture analysis Picture editing 1. On the picture preview interface, click any picture to enter the interface for picture editing. 2. Click the button [ ], the system will enter the editing mode automatically. Editing of analysis object 3. Click the [parameter] button to modify other attributes and save settings when exiting as shown below.
Picture analysis PDF printing 1. Connect to the wireless printing network (wireless printing) by system settings-connection settings interface. 2. Enter the gallery interface, select one picture, and carry out printout of a 3. Touch and press the [printing] button at upper right of the preview interface; 4.
Picture analysis Video playback 1. Enter the gallery interface, click “picture”- “local video” to successfully enter the local 2. Playback of video: Steps: Click the “play” button at the middle of the screen to start playing the video . Click the screen to arouse the video playback interface.
Picture analysis Video analysis 1. Enter the settings-system settings interface, switch the video format to “irgd” format, as shown below: 2. Enter the shortcut menu, click “camera mode” button, switch the camera mode into “recording mode”, and start recording. 3. Enter the gallery, select the recorded video ”...
Page 46
Picture analysis 4. Click the “ ” button at top left corner to play the video, and click the “ ” button to pause. 5. After clicking the shortcut menu button, the system will pop up a tool menu for “objects” and “parameters”, where objects can be added for real-time analysis.
Isotherm 1. Under real-time menu state, click the gallery button [ interface. 2. On the picture browsing interface, select one IR picture for editing. 3. After calling out the editing menu from the bottom, select the object-isotherm. Below isotherm 1. Call out the main editing menu, and enter the object-isotherm.
Isotherm Above isotherm 1. Call out the main editing menu, and enter the object-isotherm. 2. Click the icon [ ] to enter the above isotherm mode. External isotherm...
LEVEL and SPN functions 1. On the real-time imaging interface, click the temperature data area at top or bottom of the color palette (the yellow box area as shown in Fig. 1), to enter the “manual dimming mode”, and lock the dimming parameters (as shown in Fig.
Customized emissivity 1. Enter the main editing menu, and select the option of parameter-[material]; Multiple preset values are provided at present, as shown in 2. Select your own value to modify the par- ameters with the range controlled in 0.01-1.00; shown below: Introduction to customized parameters: in the range of 0-100.
System settings On the real-time video interface, click the setting button at bottom of the screen to enter the interface of system settings. The setting interface is used to modify the main parameters of the system, including temperature unit, distance unit, brightness, network connection, dateand language. Center temperature cursor It is mainly used to control the display of center temperature cursor and temperature data on...
System settings Switch of temperature unit It can be used to switch the degree between centigrade and Fahrenheit shown in the system. (The defaulted temperature unit is degree centigrade Switch of distance unit Switch the distance units between meter and yard.
System settings Alarm setting Control the alarm temperature and range. The defaulted state of alarm is off state. The alarm temperature range shall be obtained from the temperature measurement range. If the temperature range is set as -20 ~150 , the alarm temperature range shall be selected from that range.
System settings 1. Turn on the temperature alarm switch, set the alarm temperature range into low temperature and the alarm temperature to 30 . 2. After returning to the real-time temperature measurement interface, the device will give an audio alarm immediately. 3.
System settings Scheduled shutdown Set the option of schedule shutdown; the default value is “never”. Options of shutdown after 5min, 10min, 30min or 60min and “never” are provided. Scheduled sleep Set the option of schedule sleep. The default value is “never”. Options of sleep after 1min, 5min, or 15 min and “never”...
System settings Automatic lens recognition As defaulted, the automatic lens recognition function is turned on, and the program will automatically recognize the corresponding options by the lens installed in the device. Disabling of automatic lens recognition Turn off the lens recognition function. User can manually select from standard lens, telephoto lens or wide-angle lens based his own lens.
System settings Temperature marker on full screen Control the high/low temperature tracking mode on the real-time image. The defaulted value is “no display” (turn off the high/low temperature tracking). Color of isotherms Provide customized color display of high-tem- perature isotherm, low-temperature isotherm and external isotherm.
Local settings Photo shooting setting Photo shooting mode, including three modes of “freezing / photographing”, “photographing” and “freezing”. Freezing / shooting mode: press the shoot button to freeze the photo, and press the shoot button again to save the photo. Shooting mode: press the shoot button to take a photo and save the photo directly;...
Local settings Video format The system provides two optional video formats format contain temperature information, and can be analyzed. (See the part of video analysis in this Manual for details) Report setting Various parameters of PDF report (including watermark, report header, report footer, PDF template (three preset templates provided))
Local settings Watermark setting 1. Enter watermark setting and enable some date watermark, emissivity watermark, distance temperature watermark. 2. Return to the real-time picture and take a sample picture at random. 3. Press the quick playback button and enter the picture browse interface. Select the picture taken just a minute earlier for preview.
Connection settings WIFI switch If the symbol of [ ] occurs at the top of main screen, it indicates that the device has been linked to the wireless local area network. (Control enabling and disabling functions of WIFI module) 1. Select a network: slightly click one network listed and enter the password (if required).
Page 65
Connection settings 3. Click “More” button [ ] to enter the WIFI address setting interface. Ignore a network: slightly click “More” button beside the network added earlier and then 1. Enter “System settings -- Connection settings name (Camera) and password (12345678) of hotspot and click “Save”.
Connection settings Bluetooth (Only certain models of device support this function) 1. Enter the “System settings -- Connection settings -- Bluetooth” interface, turn on the Bluetooth switch, activate Bluetooth function and search device. conduct Bluetooth pairing. Successfully link after Bluetooth pairing and then use Bluetooth function normally.
About upgrade Program upgrade 1. Put APK program upgrade patch under the route of Computer/IrCamera/ Internal storage/GCameraExt/Update, as shown below: 2. Enter “system settings -- information” interface, click program upgrading. the prompt to install. Restart the device after successful upgrading, as shown below: Firmware upgrade IrCamera/Internal storage/GCameraExt/FirmwareUpdate, as shown below:...
Page 68
About upgrade prompt. Restart the device after successful upgrading, as shown below: below:...
Page 69
About upgrade prompt. Restart the device after successful upgrading, as shown below:...
About upgrade Storage space Mainly display the residual capacity of internal storage and basic information of external TF card. In addition, users may customize storage option setting, including internal storage and storage of external TF card. (Select the storage medium: enter “system settings -- information -- storage space”...
About upgrade Formatting TF card For formatting, select a slot of memory card and then select “Yes”. Note that all photos and other data on the memory card will be deleted permanently after formatting. Please make backups if needed prior to formatting. Data synchronization Data synchronization may be conducted for...
About upgrade Restore default settings 1. Enter “system settings -- information -- restore all settings” and click “Restore settings” tag. 2. The device will be restored to the factory state through the function. Please be careful.
Port connection The device can be connected to external devices through HDMI cable and USB cable. Micro HDMI interface Micro HDMI interface is mainly used to be connected to an external HD display. Please ensure that the display to be connected is provided with an HDMI interface.
Port connection Connect to the computer through USB cable, open “My Computer” and view the Storage Location File Format Storage Path IrCamrea/SD card/DCIM/GCamera/ SD card Images SourceImage IrCamrea/ SD card/DCIM/GCamera/ SD card Videos SourceVideo Computer settings for connection to IR analysis software Before connection to the IR analysis software, the driver shall be installed.
Page 76
Port connection device manager IrCamera other devices as below. IrCamera updating driving application software...
Page 77
Port connection choose from the device driving application lists in this computer next step” as below network adapter next step Microsoft Corporation Remote NDIS compatible Devics network adapter selecting item box and click “next step” as below.
Page 78
Port connection 8. after assemble the driving application successfully, the computer will inform that ” ” as below.
Page 79
Port connection IrCamera Network adapter device manager...
Page 80
Port connection Windows 10 driver installation method: 1. Signature-disable the win10 operating system driver.
Page 83
Port connection 9. after the driver installation is complete, enter in the Device manager, in installation is complete. Note: Computer drivers installed successfully, you can connect the infrared analysis software now!
Port connection IR analysis software connection 1. Enter the setting interface of “TCP/IP v4”, set the attribute of “Internet protocol version 4 (TCP/IPv4)” as “Automatic acquisition of IP address” and “Automatic First step Second step Infrared analysis software as shown below.
Page 85
Port connection Video analysis model. Select “USB” in the popped dialog box of connection setting, as shown below. software from computer will display real-time infrared image and analyze correspondingly, as shown below.
Installing memory card and lens The device may use a TF card and images and videos taken can be recorded on the device or TF card. The device supports a TF card with capacity of 32GB at most. Ensure the write-protect switch of memory card is set at the upper to allow write/delete.
Installing memory card and lens Removing memory card 1. Turn off the power and open the slot cover. (Make sure the indicator light is off and open the slot cover) 2. Take out the memory card: for exiting the memory card, slightly push the memory card and then release.
Installing memory card and lens Assemble optional lens 1. Remove the standard lens: press and hold the lens-disassemble button, rotate anticlockwise to remove the standard lens. 2. Choose appropriate lens, connect it to the thread interface and rotate clockwise to assemble the lens. (The wide angle lens) (The tele lens) 3.
Installing memory card and lens Assemble high-temperature lens (Not all products support optional lens) 1. Assemble high-temperature lens: high-temperature lens is optional lens, no need to disassemble the standard lens, directly connect it to the thread interface of the standard lens and rotate clockwise to assemble.
External connection Wireless AP setting 1. Call out the shortcut menu interface at the bottom of the main screen, directly click [Hotpot] AP button to activate wireless AP function. 2.The status bar will automatically display that AP function has been activated. Conduct signal search through the wireless network card.
Capítulo 3 Descripción general de la unidad central Manual de usuario...
Page 110
Descripción general de la unidad central Áreas funcionales estado Manual de usuario...
Page 111
Descripción general de la unidad central Galería Manual de usuario...
Page 112
Descripción general de la unidad central Menú rápido Como entrar en el menú rápido Modo de cámara: Modo de infrarrojos: Lámpara: Láser: Abriendo AP: Manual de usuario...
Page 113
Descripción general de la unidad central Compensación del obturador: Zoom electrónico: Manual de usuario...
Capítulo 5 Filmación Toma de fotografías Grabación de vídeo Análisis en tiempo real Navegación de archivos Análisis de imágenes Isotermas Funciones LEVEL y SPN Emisividad personalizada Manual de usuario...
Page 119
Toma de fotografías * Asegúrese de que el dispositivo esté en modo de toma de fotografías antes de disparar Manual de usuario...
Page 120
Toma de fotografías Añadiendo anotaciones Manual de usuario...
Page 121
Toma de fotografías Adición de anotaciones de disparo Manual de usuario...
Page 122
Toma de fotografías Adición de anotaciones de texto Adición de anotaciones de audio Manual de usuario...
Page 123
Toma de fotografías Adición de dibujos de anotaciones Manual de usuario...
Análisis en tiempo real Añadiendo/Eliminando objetos de análisis Etiqueta: Contenido de la etiqueta: Centrado: Manual de usuario...
Page 126
Análisis en tiempo real Curva de temperatura de un objeto en tiempo real Manual de usuario...
Page 127
Análisis en tiempo real Manual de usuario...
Page 128
Análisis en tiempo real Cambio de paleta de colores Manual de usuario...
Page 129
Análisis en tiempo real Ajuste manual de brillo / contraste Manual de usuario...
Page 130
Análisis en tiempo real Análisis de la diferencia de temperatura de temperatura. Antes del análisis de la Después del análisis de la diferencia de temperatura diferencia de temperatura de temperatura. Salir del análisis de diferencia de temperatura Manual de usuario...
Ajustes del sistema Temperatura en el cursor central Rango de medición de temperatura Manual de usuario...
Page 145
Ajustes del sistema Cambio de unidades de temperatura Cambio de unidades de distancia Manual de usuario...
Page 146
Ajustes del sistema Ajustes de alarma Alarma por altas temperaturas ] para apagar Manual de usuario...
Page 147
Ajustes del sistema Alarma por bajas temperaturas Manual de usuario...
Page 148
Ajustes del sistema Apagado programado Reposo programado Manual de usuario...
Page 149
Ajustes del sistema Volumen Vibración de respuesta Manual de usuario...
Page 150
Ajustes del sistema Reconocimiento automático de lentes Apagado de reconocimiento automático de lentes Manual de usuario...
Page 151
Ajustes del sistema Marcador de temperatura a pantalla completa Color de isotermas Manual de usuario...
Page 152
Ajustes locales Ajustes de fotografía Modo de congelación / disparo: Modo de disparo: Modo de congelación: Ajustes de resolución para la imagen visible Manual de usuario...
Page 153
Ajustes locales Formato de video Manual de usuario...
Page 154
Ajustes locales Idioma Manual de usuario...
Page 155
Ajustes locales Ajustes de marca de agua Manual de usuario...
Conexión de puertos conectado. 1. Ver el archivo de almacenamiento interno: Almacenamiento Formato de archivo Localización I r C a m r e a / O n b o a r d _ Memoria interna Imágenes Memory/DCIM/GCamera/ SourceImage I r C a m r e a / O n b o a r d _ Memoria interna Vídeos Memory/DCIM/GCamera/...
Page 167
Conexión de puertos Almacenamiento Formato de archivo Localización IrCamrea/SD_Card/DCIM/ Tarjeta SD Imágenes GCamera/SourceImage IrCamrea/SD_Card/DCIM/ Tarjeta SD Vídeos GCamera/SourceVideo Método de instalación del controlador de Manual de usuario...
Page 175
Conexión de puertos Nota: Los controladores de la computadora se instalaron ahora! Sugerencias: descargue el controlador de la tarjeta suministrada. Manual de usuario...
Page 176
Conexión de puertos Primer paso Segundo paso Manual de usuario...
Instalación de tarjeta de memoria y lentes • Instalación de tarjeta de memoria Nota: los disparos restantes dependen del almacenamiento residual de la tarjeta de memoria y la calidad de grabación de la imagen. Manual de usuario...
Page 179
Instalación de tarjeta de memoria y lentes Extracción de tarjeta de memoria Manual de usuario...
Page 180
Instalación de tarjeta de memoria y lentes Instalación de lentes opcionales (Lente gran agular) (Teleobjetivo) Manual de usuario...
Page 181
Instalación de tarjeta de memoria y lentes Instalación de lentes para altas temperaturas (Filtro de alta temperatura) Manual de usuario...
Page 182
Conexiones externas Adquisición de últimas versiones (IOS / Android) más detalles. Versión IOS: acceda a Apple Store Termography Versión de Android: Termography Manual de usuario...
Page 183
Capítulo 8 Guía de resolución de problemas Preguntas más frecuentes Manual de usuario...
Page 184
Guía de resolución de problemas Preguntas más frecuentes Problema Causa Acción Batería baja Usar batería después de cargarla Retire la batería, colóquela en el compartimiento de la batería Mal contacto de la batería Fallo de encendido nuevamente e instale correctamente la batería El enchufe de la batería externa no está...
Page 185
Preguntas más frecuentes Problema Causa Acción To ensure temperature measurement La medición de temperatura comienza accuracy, we recommend you to turn inmediatamente después de la puesta on the thermal imager and then wait en marcha for 5-10 minutes before temperature measurement.
Page 186
ASIA-PACIFIC TAIWAN CHINA Flat 4-1, 4/F, No. 35, 72 Puxing East Road, Qingxi, Section 3 Minquan East Road Dongguan Guangdong, Taipei, Taiwan China Tel: +886 2-2508-0877 Tel: +86 769-8190-1614 Fax: +886 2-2506-6970 Fax: +86 769-8190-1600 info.apac@mgl-intl.com info.apac@mgl-intl.com AMERICA MEXICO 760 Challenger Street Brea, 2810 Coliseum Centre Drive, Calle Poniente 122, No.
Page 188
USER MANUAL MANUAL DE USUARIO Thank you for choosing our product. Please thoroughly go through user manual before operation and keep it well for future reference. All photos here are for reference only, and specifications are subject to the phisycal product. Gracias por elegir nuestro producto.
Page 189
............. 1 Software environment ......................1 Hardware environment ......................1 ..............3 Windows XP .......................... 3 Windows 7 ..........................6 Frequently asked questions (FAQ) and answers ..............9 ................... 11 ........................11 Data Import ......................... 11 Folder creation ........................13 Picture property view ......................
Page 190
................43 ..............43 ............. 45 ..................... 45 ............ 45 Template start ........................45 IR picture ..........................46 Text comment ........................47 Voice comment ........................47 Picture information ......................48 Analysis object information ....................48 Display of temperature difference ..................49 Distribution graph of line temperatures ................
Page 191
CHAPTER 1 SOFTWARE AND HARDWARE CONFIGURATION .net framework 3.5 SP1 and above; Operating environment Microsoft Visual C++2010 x86 Redistributable; WindowsInstaller3_1; Operating system Windows XP 32-bit/64-bit and above Other software PDF viewer software Above Pentium4 2.4GHz Memory Above 512M Graphics card Above NVIDIA GeForce 5200 128M Above 40G, with space left in disk upon installation not less Hard disk...
Page 192
CHAPTER 2 SOFTWARE INSTALLATION INSTRUCTION Download and install the following components in order: 1. Install the version .net Framework3.5 SP1 (X86/X64) and above; 2. Install the Visual C++ 2010/2012/2013 Redistributable and above, and select any one (X86/X64) of them; 3. Install the main program of the infrared analysis software. complete the installation.
Page 193
CHAPTER 2 SOFTWARE INSTALLATION INSTRUCTION USER MANUAL...
Page 194
CHAPTER 2 SOFTWARE INSTALLATION INSTRUCTION 3 The installation process takes about 7-10 minutes. See Figure 2-7: 5 Upon installation, access to the control panel to check whether the installation is successful. USER MANUAL...
Page 195
CHAPTER 2 SOFTWARE INSTALLATION INSTRUCTION Access to the Control Panel - Programs and Features - Turn Windows Features on or off. Please Figure 2-12: USER MANUAL...
Page 196
CHAPTER 2 SOFTWARE INSTALLATION INSTRUCTION Go to the environmental inspection installation steps, followed by the necessary installation USER MANUAL...
Page 197
CHAPTER 2 SOFTWARE INSTALLATION INSTRUCTION 4 Go to the main program installation interface successfully. See Figure 2-18: 5 After installation, access to the Control Panel (Start-Control Panel-Programs and Features) to check whether the installation is successful. USER MANUAL...
Page 198
CHAPTER 2 SOFTWARE INSTALLATION INSTRUCTION USER MANUAL...
Page 199
CHAPTER 3 INSTALLATION INSTRUCTIONS Open the infrared analysis software, with the operation interface as shown in Figure 3-1: Folder: Directly copy a picture to be viewed to \\Home Directory\All Files (Guide Files) Folder or subfolder, then open the main program to view the picture in the left directory bar. When the number of pictures in the folder is large, you are recommended to import picture data in this way.
Page 200
CHAPTER 3 INSTALLATION INSTRUCTIONS device and the IP address of the present computer are in the same LAN segment). For example, : 192.168.42.1 DNS Server: 192.168.42.1; PC IP: 192.168.42.100 : 192.168.42.1 DNS server: 192.168.42.1. After setting, click the LAN quick toggle to turn on the network connection function of the device.
Page 201
CHAPTER 3 INSTALLATION INSTRUCTIONS Two-level folder directory creation is supported at most. See Figure 3-5: Folder deletion: Select any folder in the left resource directory, click the button [-] to pop up a deletion close the current dialog box. See Figure 3-6: USER MANUAL...
Page 202
CHAPTER 3 INSTALLATION INSTRUCTIONS Click the picture thumbnail to display picture properties in the right interface, including the shooting equipment, important level, file size, shooting time, modification time, infrared resolution, white resolution and some infrared parameters and temperature measurement information. See Figure 3-7: the user can view the corresponding information: : Click the icon to play the record notes;...
Page 203
CHAPTER 3 INSTALLATION INSTRUCTIONS See Figure 3-8: Ribbon temperature display area Display method Tool menu Visible picture Picture information display area Picture dimming area Point Line Iseoric Line Rectangle Circle Polygon Save Data 3D Display Picture Fusion Report Output Ribbon Change Isotherm Original Scale Histogram...
Page 204
CHAPTER 3 INSTALLATION INSTRUCTIONS analysis interface and load the picture. : Go to the picture analysis interface, click the button [ ], and select any infrared picture to load. : Select a valid infrared picture, directly drag it to the picture analysis interface, so that the program will automatically identify and display the relevant information.
Page 205
CHAPTER 3 INSTALLATION INSTRUCTIONS A user can add multiple analysis objects to infrared pictures, such as point analysis, line analysis, iseoric line, rectangular area analysis, circular area analysis and polygon analysis. At the same time, the right temperature measurement object information will list related object analysis information, including the maximum temperature, minimum temperature and average temperature.
Page 206
CHAPTER 3 INSTALLATION INSTRUCTIONS (2 options are available): Click the button [ ] to delete a single analysis object; Click the button [ ] to delete all analysis objects in a picture. Click the button [Note template. USER MANUAL...
Page 207
CHAPTER 3 INSTALLATION INSTRUCTIONS Click the analysis object export button [ Select an analysis object, and then click the button [ ] . In the pop-up dialog box interface, select USER MANUAL...
Page 208
CHAPTER 3 INSTALLATION INSTRUCTIONS In the data list containing temperature measurement object information, select any analysis object, and left double-click the name of the analysis object, so that the system will automatically pop up the Support the temperature alarm function for analysis object. See Figure 3-16: maximum temperature of the analysis object is greater than the set threshold, the analysis object constantly flickers to remind, otherwise there is no alarm.
Page 209
CHAPTER 3 INSTALLATION INSTRUCTIONS Click the button [ ] to allow the current picture to undergo 3D display. Rick click to rotate, zoom in or zoom out the 3D picture. See Figure 3-17: Click the button [ ] to allow the current picture to enter the picture fusion status, use the mouse to move, zoom in or zoom out the fusion picture, and adjust the infrared picture with the customized temperature range.
Page 210
CHAPTER 3 INSTALLATION INSTRUCTIONS Move the mouse pointer to the value area below the fusion interface, and then use the mouse wheel to slide up and down, and click the button to modify. See Figure 3-19, 9 ribbons are available for switching, so that the user is free to select and change the ribbon range. Click the button [ ] to display the ribbon panel, then the user is free to select and restore display of any ribbon.
Page 211
CHAPTER 3 INSTALLATION INSTRUCTIONS Single analysis object: select any of analysis objects in the data list of temperature measurement object information and double left click the name of the analysis object, then the system will automatically pop up the main editing interface of the analysis object, and the user can select the emissivity editing interface.
Page 212
CHAPTER 3 INSTALLATION INSTRUCTIONS analysis objects. See Figure 3-24: The picture analysis function supports the addition of high isotherm, low isotherm, isotherm inside the interval and isotherm outside the interval to pictures. Click the isotherm icon [ ] on the toolbar to enter the isotherm setting interface, then the user can customize the thresholds of high isotherm, low isotherm and isotherms inside/outside the interval and Left click the color zone on the right of the color zone to set high temperature color for high temperature.
Page 213
CHAPTER 3 INSTALLATION INSTRUCTIONS the set isotherm is not higher than this high temperature value and the isotherm is displayed in the the set isotherm is not lower than this low temperature value and the isotherm is displayed in the set the isotherms inside the high temperature interval and low temperature interval, and the set USER MANUAL...
Page 214
CHAPTER 3 INSTALLATION INSTRUCTIONS set the isotherms outside the high temperature interval and low temperature interval, and the set Select any analysis object then click the histogram icon [ ] on the toolbar, after that the histogram information will be displayed in the view area immediately. See Figure 3-30: USER MANUAL...
Page 215
CHAPTER 3 INSTALLATION INSTRUCTIONS Click the original scale button [ ] on the toolbar and the current infrared picture will automatically restore the original picture mode. See Figure 3-31: Add at least 2 analysis objects, and click the temperature difference analysis button [ ] in the picture, then the system will automatically list the data of temperature differences among the maximum temperature, the minimum temperature and the average temperature.
Page 216
CHAPTER 3 INSTALLATION INSTRUCTIONS button [ ] is only displayed when circle, rectangle and polygon analysis objects are added (click the auto dimming button [ ] to restore the initial picture). Select the analysis object, and click the local dimming button, then the dimming parameter will change with it.
Page 217
CHAPTER 3 INSTALLATION INSTRUCTIONS Select a valid device in the model list, and the real-time picture, video parameters and infrared parameters information will be displayed after successful connection of the device. Take the C series device as an example to introduce the video analysis connection as follows: 1.
Page 218
CHAPTER 3 INSTALLATION INSTRUCTIONS 3 Utilize the network cable equipment to connect the PC reliably and click the device LAN shortcut to open the network connection function of the device. Open the infrared analysis software to box and input the device IP. See Figure 3-36: USER MANUAL...
Page 219
CHAPTER 3 INSTALLATION INSTRUCTIONS Shoot: the user can specify the saving path for photo storage; Provide MP4 and IRGD video formats, in which IRGD video format carries with temperature information data and the video can be edited and analyzed; this tool enables to view the real-time variation curve of the maximum temperature, the minimum temperature and the average temperature.
Page 220
CHAPTER 3 INSTALLATION INSTRUCTIONS By clicking the button in the interface, you can import the video data in irv, avi, mp4, irgd objects). See Figure 3-40 below: Picture browsing area Object adding area Alignment LOGO selection Report editing area Report output Pages USER MANUAL...
Page 221
CHAPTER 3 INSTALLATION INSTRUCTIONS Method 1: Click the open icon [ up path selection dialog box to load the selected picture into the report template; Method 2: Double click the target infrared picture in the left picture browsing area, the software will automatically load the selected picture into the report template.
Page 222
CHAPTER 3 INSTALLATION INSTRUCTIONS interface and load the selected infrared picture. At this time the user can make any analysis and 3-44: 3. After the analysis is complete, click the report generation button [ ] in the menu bar, the system See Figure 3-45: USER MANUAL...
Page 223
CHAPTER 3 INSTALLATION INSTRUCTIONS 4. The software will automatically generate a report and will automatically update all parameters of the current infrared picture. See Figure 3-46: The user can edit the report template as required, including addition of text, comment, table and mark information.
Page 224
CHAPTER 3 INSTALLATION INSTRUCTIONS The user can click the button [ ] on the toolbar to add a comment box with a title in the template font size of the title, bold font of the title, font size of the contents, bold font of the contents, type of the table and other information, as shown in Figure 3-48: The user can click the button [ ] on the toolbar to add a custom table.
Page 225
CHAPTER 3 INSTALLATION INSTRUCTIONS The user can click the button [ ] on the toolbar to add an arrow mark in the template area. The user can locate the arrow mark in the report template as needed. When selecting an arrow, the user can redirect it by moving the dots at both ends of the arrow, as shown in Figure 3-50: After loading a picture, the user can click the button [ ] on the toolbar to designate a pending area...
Page 226
CHAPTER 3 INSTALLATION INSTRUCTIONS Change the default report icon: The user can click the button [Browse] and select the local picture to change the current report icon. Restore the default icon: The user can click the button [Use Default] to restore the default icon and keep it consistent with the report icon.
Page 227
CHAPTER 3 INSTALLATION INSTRUCTIONS Support two report templates (PDF and WORD). The user can select the expected template through interface of PDF report, as shown in Figure 3-54: after setup to save the current setup; the user can restore the default setup by clicking the button USER MANUAL...
Page 228
CHAPTER 3 INSTALLATION INSTRUCTIONS interface of Word report, as shown in Figure 3-55: after setup to save the current setup; the user can restore the default setup by clicking the button Other Use a device with a picture stitching function to shoot nine pictures, import these pictures into the all the nine pictures that need to be stitched, so that the panoramic stitching picture is generated and can be saved locally., as shown in Figure 3-56: USER MANUAL...
Page 229
CHAPTER 3 INSTALLATION INSTRUCTIONS When setup the menu interface, the user can set the language, unit, display, report, etc. as needed. The detiled setup is shown as follows: shown in Figure 3-57: and inch) options, as shown in Figure 3-58: USER MANUAL...
Page 230
CHAPTER 3 INSTALLATION INSTRUCTIONS Provide the object mark, full picture mark and color options for analysis object, as shown in Figure 3-59: Provide PDF/Word custom report picture, report header, report footer, and auto-open default setup. If the auto-open option is selected, the generated report file will automatically call the program associated with the system to open and view the report (refer to setup of PDF and Word reports).
Page 231
Step click the wireless connection icon to display the wireless connection searching interface, select SSID as the wireless network of ez Share, and enter the key of 88888888 to connect to the network. See Figure 4-1: Start the main program of the infrared analysis software, click [ ] - [ WIFI ], and then click the button [ Refresh USER MANUAL...
Page 232
Step default gateway and DNS. See Figure 4-3 USER MANUAL...
Page 233
For windows 7 or windows xp system, log into the system as a standard user, and then execute the installation steps of the program. Make sure that the default path is changed into a non-system disk path to install the program successfully (e.g. non-system disk E:\InfraredAnalysis\). normal operation of the program.
Page 234
pictures sent into the template, the number of required template pages is calculated to compose a Word document; the contents of all templates in the Word document are enclosed between the <#PageStart#> and <#PageEnd#>; the <# PageEnd #> is followed by an automatically created page; See Figure 4-6: 4.2 IR picture (<#IR_Picture#>) and visible picture (<#IR_Photo#>):...
Page 235
4.3 Text comment The label must be located in the [Shapes -> Textbox], or it cannot be identified; the program will changed in development of the template, such as font size and font color; See Figure 4-8: 4.4 Voice comment (<#VoiceComment#>) The label must be located in the [Shapes ->...
Page 236
: picture name (<#IR_FileName#>), shooting date (<#IR_CreateDate#>), shooting time (<#IR_CreateTime#>), emissivity (<#IR_Emissivity#>), humidity (<#IR_Humidity#>), distance (<#IR_ Distance#>), ambient temperature (<#IR_Ambient#>), maximum temperature of picture (<#IR_ maxTemp#>), minimum temperature of picture (<#IR_minTemp#>). changed in development of the template, such as font size and font color; See Figure 4-10: (<#AnalysersTable#>): The label must be located in the [Table], and the table can only consist of two columns;...
Page 237
(<#AnalysersDiffTTable#>) The label must be located in the [Table], and the table can only consist of two columns; otherwise, text message; therefore, other properties can be changed in development of the template, such as font size and font color; the program will add or delete the table rows depending on the number of the analysis objects;...
Page 287
ÍNDICE ............. 1 Entorno de software ........................ 1 Entorno de hardware ....................... 1 ............2 Windows XP ..........................2 Windows 7 ..........................5 Preguntas frecuentes (FAQ) y respuestas ................8 ................9 ....................... 9 Importación de datos ......................9 Creación de carpetas ......................11 Vista de propiedades de imagen ..................
Page 288
ÍNDICE ..................41 ..............41 ............ 43 ............43 ....... 43 Inicio de plantilla ......................... 43 Imagen IR ........................... 44 Comentario de texto ......................45 Comentario de voz ......................45 Información de la imagen ....................46 Información del objeto de análisis ..................46 Visualización de la diferencia de temperatura ..............
Page 289
Descripción del requisito Requisitos detallados .net framework 3.5 SP1 y superior Entorno operativo Microsoft Visual C ++ 2010 x86 redistribuible WindowsInstaller3_1 Sistema operativo Windows XP 32-bit/64-bit o superior Otro software Visualizador de archivos PDF Descripción del requisito Requisitos detallados Pentium4 2.4GHz o superior Memoria 512MB o superior NVIDIA GeForce 5200 128MB o superior...
Page 290
Descargue e instale los siguientes componentes en orden: 1. Instale la versión .net Framework3.5 SP1 (X86 / X64) o superior; 2. Instale Visual C ++ 2010/2012/2013 Redistributable o superior, y seleccione cualquiera (X86 / X64) de ellos; 3. Instale el programa principal del software de análisis de infrarrojos. Cuando lo instale por primera vez, hágalo con “Un clic”.
Page 292
3. El proceso de instalación tarda entre 7 y 10 minutos. Vea la Figura 2-7: 2-11: 5. Tras la instalación, acceda al panel de control para comprobar si la instalación se ha realizado correctamente.
Page 293
1. Acceso al Panel de control - Programas y funciones - Active o desactive las funciones de Windows. Por favor compruebe si se ha instalado .NET Framework 3.5.1. Si no está instalado, seleccione “Continuar”. Ver Figura 2-12: 2. Para instalar con “Un clic”, haga clic en setup.exe. Vea la Figura 2-13:...
Page 294
3. Continúe por los pasos de instalación de la inspección del entorno, seguido de la instalación...
Page 295
4. Vaya a la interfaz de instalación del programa principal correctamente. Vea la Figura 2-18: 5. Después de la instalación, acceda al Panel de control (Inicio-Panel de control-Programas y características) para comprobar si la instalación se ha realizado correctamente.
Page 296
a. Haga doble clic en el acceso directo para ejecutar el programa. Si aparece el mensaje de error 1 b. Si aparece un mensaje de error 2 “Normal initialization (0xc0000135) of the application fails”:...
Page 297
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Abra el software de análisis de infrarrojos, con la interfaz de operación como se muestra en la Figura 3-1: Se proporciona una multitud de métodos de importación de datos como WIFI, USB, FTP y “Carpeta”. Se sugiere utlizar el método de importación “Carpeta”, al importar datos de imágenes, especialmente una gran cantidad de imágenes.
Page 298
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN dirección IP del dispositivo y la dirección IP de la computadora actual están en el mismo segmento de LAN). Por ejemplo, 192.168.42.1 192.168.42.1; 192.168.42.100 192.168.42.1 192.168.42.1. para activar la función de conexión de red del dispositivo. 2.
Page 299
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Haga clic en el botón [+] en el directorio de recursos de la izquierda “Todos los archivos” para que aparezca el cuadro de diálogo Nueva carpeta, ingrese un nombre de carpeta válido (por ejemplo “Archivo”), haga clic en [Aceptar], agregue la carpeta y, a continuación, visualice en el directorio de recursos de la izquierda.
Page 300
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Haga clic en la miniatura de la imagen para mostrar las propiedades de la imagen en la interfaz de la derecha, incluyendo el equipo de captura, el nivel de importancia, el tamaño del archivo, la fecha parámetros de infrarrojos e información de medición de la temperatura.
Page 301
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Vea la Figura 3-8: Área de visualización de la banda de temperaturas Método de visualización Menú de herramientas Imagen visible Área de visualización de información de imagen Área de atenuación de imagen Abra la imagen infrarroja Punto Línea Línea Iseoric...
Page 302
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Examine el módulo de archivo, seleccione una imagen infrarroja y haga doble clic para ingresar a la interfaz de análisis de imágenes y cargue la imagen. Vaya a la interfaz de análisis de imágenes, haga clic en el botón [] y seleccione cargar cualquier imagen infrarroja.
Page 303
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN El usuario puede agregar múltiples objetos de análisis a imágenes infrarrojas, como por ejemplo análisis de puntos, análisis de líneas, línea iseórica, análisis de áreas rectangulares, análisis de áreas circulares y análisis de polígonos. Al mismo tiempo, la información correcta del objeto de medición de temperatura enumerará...
Page 304
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN 3-12: Haga clic en el botón [ ] para eliminar un solo objeto de análisis; Haga clic en el botón [ ] para eliminar todos los objetos de análisis en una imagen. Haga clic en el botón [Nota], introduzca cualquier contenido en el cuadro de texto emergente y haga clic en el botón [Aceptar] para guardar.
Page 305
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Haga clic en el botón de exportación del objeto de análisis [ almacenamiento y el nombre del archivo, y haga clic en “Guardar” para exportar el archivo de texto (archivo .txt) que contiene los datos de temperatura del objeto de análisis actual. Vea la Figura 3-13: Seleccione un objeto de análisis y luego haga clic en el botón [ ].
Page 306
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN En la lista de datos que contiene la información de medición de temperatura del objeto, seleccione cualquier objeto de análisis y haga doble clic izquierdo en el nombre del objeto de análisis, de modo que el sistema abrirá automáticamente la interfaz principal para editar el objeto de análisis, y el temperatura y alarma.
Page 307
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Haga clic en el botón [ ] para permitir que la imagen actual se muestre en 3D. Haga clic derecho para rotar, acercar o alejar la imagen en 3D. Vea la Figura 3-17: Haga clic en el botón [ ] para permitir que la imagen actual entre en el estado de fusión de la imagen, use el ratón para mover, acercar o alejar la imagen de fusión y ajustar la imagen infrarroja con el rango de temperatura personalizado.
Page 308
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Mueva el puntero del mouse al área de valor debajo de la interfaz de fusión y luego use la rueda del 3-19, Hay 9 bandas disponibles para cambiar, de modo que el usuario es libre de seleccionar y cambiar el rango de la banda.
Page 309
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Objeto de análisis único: seleccione cualquiera de los objetos de análisis en la lista de datos de la información del objeto de medición de temperatura y haga doble clic izquierdo en el nombre del objeto de análisis. El sistema mostrará automáticamente la interfaz de edición principal del objeto de análisis, y el usuario podrá...
Page 310
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Haga doble clic en la etiqueta “Distancia” en el área de parámetros de infrarrojos, aparecerá el cuadro seleccionar la distancia actual para aplicarla a todos los objetos de análisis. Vea la Figura 3-24: La función de análisis de imagen admite la adición de isoterma alta, isoterma baja, isoterma dentro del intervalo e isoterma fuera del intervalo a las imágenes.
Page 311
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Abrir isoterma alta: Establezca las isotermas dentro del intervalo de alta temperatura y el intervalo de baja temperatura.
Page 312
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Establezca las isotermas fuera del intervalo de temperatura alta y el intervalo de temperatura baja. Seleccione cualquier objeto de análisis y, a continuación, haga clic en el icono de histograma ] en la barra de herramientas. La información del histograma se mostrará en el área de visualización inmediatamente.
Page 313
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Haga clic en el botón de escala original [] en la barra de herramientas y la imagen infrarroja actual se restaurará automáticamente al modo de imagen original. Vea la Figura 3-31: Agregue al menos 2 objetos de análisis y haga clic en el botón de análisis de diferencia de temperatura [ ] en la imagen.
Page 314
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN La función de atenuación local se utiliza principalmente para trabajar en conjunto con un objeto de ] solo se muestra cuando se agregan objetos de análisis de círculo, rectángulo y polígono (haga clic en el botón de atenuación automática [ ] para restaurar la imagen inicial).
Page 315
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Seleccione un dispositivo válido en la lista de modelos, y la imagen en tiempo real, los parámetros de video y la información de los parámetros infrarrojos se mostrarán después de la conexión exitosa del dispositivo. Tome el dispositivo de la serie C como ejemplo para presentar la conexión de análisis de video de la siguiente manera: estar en el mismo segmento de red).
Page 316
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN directo de LAN del dispositivo para abrir la función de conexión de red del dispositivo. Abra el software de análisis de infrarrojos para seleccionar “CSeries” en el área de selección de modelo, seleccione Vea la Figura 3-36: 4.
Page 317
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Proporciona formatos de video MP4 e IRGD, en los que el formato de video IRGD lleva datos de información de temperatura y el video se puede editar y analizar. Esta herramienta permite visualizar la curva de variación en tiempo real de la temperatura máxima, la temperatura mínima y la temperatura media.
Page 318
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Al hacer clic en el botón [ ] en la interfaz, puede importar los datos de video en formatos irv, avi, El botón de control debajo de la interfaz de video permite las operaciones de “Detener”, “Pausa”, “Cuadro anterior”...
Page 319
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Haga clic en el icono de abrir [ ] y haga clic en “Abrir” detrás de la imagen de destino seleccionada en la plantilla de informe. Haga doble clic en la imagen de infrarrojos de destino en el área de exploración de imágenes de la izquierda.
Page 320
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN 2. Haga clic en la etiqueta de “Análisis de imágenes”. El programa saltará automáticamente a la interfaz de análisis de imágenes y cargará la imagen de infrarrojos seleccionada. En este momento, el agregar objetos de análisis y otras operaciones). Vea la Figura 3-44: 3.
Page 321
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN 4. El software generará automáticamente un informe y actualizará automáticamente todos los parámetros de la imagen infrarroja actual. Vea la Figura 3-46: El usuario puede editar la plantilla de informe según sea necesario, incluida la adición de información de texto, comentarios, tablas y marcas.
Page 322
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN El usuario puede hacer clic en el botón [ ] en la barra de herramientas para agregar un cuadro de la tabla del cuadro de comentarios, el tamaño de fuente del título, la fuente en negrita del título, el tamaño de fuente de los contenidos, la fuente en negrita de los contenidos, el tipo de la tabla y otra información, como se muestra en la Figura 3-48: El usuario puede hacer clic en el botón [...
Page 323
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN El usuario puede hacer clic en el botón [ ] en la barra de herramientas para agregar una marca de Después de cargar una imagen, el usuario puede hacer clic en el botón [ ] en la barra de herramientas para designar un área pendiente para la imagen en la plantilla de informe según sea necesario.
Page 324
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Cambiar el icono del informe predeterminado: el usuario puede hacer clic en el botón [Examinar] y seleccionar la imagen local para cambiar el icono del informe actual. Restaurar el icono predeterminado: el usuario puede hacer clic en el botón [Usar predeterminado] para restaurar el icono predeterminado y mantenerlo coherente con el icono del informe.
Page 325
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Admite dos plantillas de informes (PDF y WORD). El usuario puede seleccionar la plantilla esperada a través de “Establecer” - “Informe” - “Salida de informe”, como se muestra en la Figura 3-53: Muestre la interfaz a través de “Establecer” - “Informe” - “PDF”, y haga clic en el botón “Establecer” El usuario puede personalizar la información de visualización relacionada con el informe PDF y hacer...
Page 326
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Muestre la interfaz a través de “Establecer” - “Informe” - “Word”, y haga clic en el botón “Establecer” El usuario puede personalizar la información de pantalla relacionada con el informe de Word y hacer Utilice un dispositivo con función de unión de imágenes para tomar nueve imágenes, importe estas imágenes a la computadora y haga clic en el botón [Abrir] en la interfaz “Otro”...
Page 327
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN informe, etc., según sea necesario. como se muestra en la Figura 3-57: Proporciona opciones de unidades de temperatura (grados Celsius, grados Fahrenheit y Kelvin) y unidades de distancia (metros y pulgadas), como se muestra en la Figura 3-58:...
Page 328
CAPÍTULO 3 INSTRUCCIONES DE INSTALACIÓN Proporciona la marca de objeto, la marca de imagen completa y las opciones de color para el objeto de análisis, como se muestra en la Figura 3-59: Proporciona una imagen de informe personalizado en PDF / Word, encabezado de informe, pie de Si se selecciona la opción de apertura automática, el archivo de informe generado llamará...
Page 329
de red en la PC, haga doble clic en el icono de conexión inalámbrica para mostrar la interfaz de búsqueda de conexión inalámbrica, seleccione SSID como la red inalámbrica de ezShare e ingrese la clave de 88888888 para conectarse a la red. Vea la Figura 4-1: Inicie el programa principal del software de análisis de infrarrojos, haga clic en [Importar datos] - [WIFI], y luego haga clic en el botón [Actualizar] para ver la información relevante del archivo.
Page 330
Conéctese a la red ezShare para mostrar la interfaz de la tarjeta WLAN e ingrese la IP...
Page 331
Para el sistema Windows 7 o Windows XP, inicie sesión en el sistema como usuario estándar y luego ejecute los pasos de instalación del programa. Asegúrese de que la ruta predeterminada se cambie a una ruta de disco que no sea del sistema para instalar el programa correctamente (por ejemplo, un disco que no sea del sistema E:\InfraredAnalysis\).
Page 332
redactar un documento de Word; el contenido de todas las plantillas en el documento de Word se incluye entre <# PageStart #> y <# PageEnd #>. El <# PageEnd #> es seguido por una página creada automáticamente. Vea la Figura 4-6: (<# IR_Picture #>) e imagen visible (<# IR_Photo #>): eliminará...
Page 333
eliminará automáticamente el contenido de la etiqueta y lo llenará con un mensaje de texto; por lo tanto, se pueden cambiar otras propiedades durante el desarrollo de la plantilla, como el tamaño y el color de la fuente. Vea la Figura 4-8: (<# VoiceComment #>) eliminará...
Page 334
Incluyendo: nombre de la imagen (<# IR_FileName #>), fecha de disparo (<# IR_CreateDate #>), tiempo de disparo (<# IR_CreateTime #>), emisividad (<# IR_Emissivity #>), humedad (<# IR_ Humidity #>), distancia (<#IR_ Distance #>), temperatura ambiente (<# IR_Ambient #>), temperatura máxima de la imagen (<#IR_ maxTemp #>), temperatura mínima de la imagen (<# IR_minTemp #> ). El programa eliminará...
Page 335
(<# AnalysersDiffTTable #>) La etiqueta debe estar ubicada en la [Tabla], y la tabla solo puede constar de dos columnas. De lo de la etiqueta y lo completará con el mensaje de texto. Por lo tanto, se pueden cambiar otras propiedades durante el desarrollo de la plantilla, como el tamaño y el color de la fuente.