BioSmart PV-WM-MU Operation Manual

Biometric reader

Advertisement

Quick Links

BioSmart PV-WM Reader
Operation Manual
Version 029.1
Date 03.2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PV-WM-MU and is the answer not in the manual?

Questions and answers

Summary of Contents for BioSmart PV-WM-MU

  • Page 1 BioSmart PV-WM Reader Operation Manual Version 029.1 Date 03.2021...
  • Page 2: Table Of Contents

    Actions Immediately Before Connection .......................... 12 2.3.4 Installation Procedure ................................13 2.3.5 Connection to BioSmart UniPass Controller ........................17 Checking the Reader's Functionality ............................18 Reader Faults and Method of Its Elimination .......................... 18 PV-WM Reader Settings..................................19 Procedure for Performing Product Application Tasks ..................... 20 Maintenance for Intended Usage ................................23...
  • Page 3: Introduction

    Introduction This operating manual (OM) applies to the BioSmart PV-WM reader and contains information on the principle of operation, technical characteristics, installation procedure and operating conditions, as well as information on the conditions of transportation, storage, maintenance and maintenance of the reader in a working condition.
  • Page 4: Description Of Reader Operation

    BioSmart UniPass controller. The BioSmart PV-WM reader is intended to read biometric data of a human palm vein pattern and RFID-tag (card) code with subsequent transfer of the read information to the BioSmart UniPass or BioSmart UniPass-EX controller via Ethernet.
  • Page 5: Composition

    The back cover of the reader can be removed to provide access to the reader board. The reader board is designed to connect the power supply and the BioSmart UniPass controller. The palm vein scanner is designed to obtain users biometric data.
  • Page 6 UniPass performs the actions specified in the working model for this situation and sends a message about successful identification to the reader BioSmart PV-WM. If the template is not found in the database or the access settings instruct to deny access, then the controller performs other actions prescribed by the working model.
  • Page 7 - palm / card standby mode;  red single - notification about unsuccessful identification;  red flashing - there is no connection with the BioSmart UniPass controller or the reader is “not tied” to the controller;  green single - notification about successful identification;...
  • Page 8 PoE support BioSmart UniPass controller Note - The BioSmart PV-WM reader is intended for use in conjunction with the BioSmart UniPass controller, which powers the readers through PoE technology, and therefore the GND and +12 V connectors on the reader are used only as backup power connectors.
  • Page 9: Measuring Instruments, Tools And Accessories

    In debug mode, the green RUN LED on the reader board blinks with a period of 1 sec (0.5 sec on, 0.5 sec off). The reader may be powered from the BioSmart UniPass controller via an Ethernet cable using PoE technology, or from a 12V DC voltage source connected to the clips on the reader board.
  • Page 10: Packaging

    Packaging The BioSmart PV-WM reader in accordance with its completeness, is placed in a consumer package, which is a cardboard box with inserts made of uncrosslinked polyethylene foam. The packaging used is intended for storage and transportation of the reader in accordance with the conditions specified in paragraph 5.
  • Page 11: Intended Usage

    After the reader has been exposed to low temperature or high humidity conditions, it must be taken out of the package and kept in a dry room at a temperature of (20 ± 5) С for at least 30 minutes before turning it on. Operation Manual BioSmart PV-WM v.029.1|03.2021|en...
  • Page 12: The Product Installation

    Absence of mechanical damage on the palm vein reader scanner surface, printed circuit board and the device case; 2) The stripped ends of the cable for connecting the reader shouldn’t exceed 5 mm to avoid short circuits. Operation Manual BioSmart PV-WM v.029.1|03.2021|en...
  • Page 13: Installation Procedure

    4) If the installation is carried out without using a protective visor, then drill holes in the marking points and install the dowels from the fastening kit. If a protective visor for the BioSmart PV-WM reader is used, then it already has holes for fastening using the bolts included in the BioSmart PV-WM visor kit.
  • Page 14 6) Fix the mounting plate by screwing self-tapping screws into the dowels or screwing the screws into the corresponding holes on the protective cover for BioSmart PV-WM. 7) Unscrew the screws on the back cover of the reader (see Figure 7), remove the back cover.
  • Page 15  “crimp” the end of the cable in accordance with Figure 9;  tightly tighten the hold-down nut from the outside of the back cover;  insert the connector into the Ethernet port. Operation Manual BioSmart PV-WM v.029.1|03.2021|en...
  • Page 16 (see Figure 7). It’s important to check that the sealing gum doesn’t squeeze out of the special recess while tightening the screws. Therefore, tighten the screws on the back cover carefully, tightening each screw in turn. Operation Manual BioSmart PV-WM v.029.1|03.2021|en...
  • Page 17: Connection To Biosmart Unipass Controller

    The interaction between the BioSmart PV-WM reader and the BioSmart UniPass controller is provided via the Ethernet interface. 2) No more than two BioSmart PV-WM readers may be connected to one BioSmart UniPass controller. Readers connection scheme is on the Figure 12.
  • Page 18: Checking The Reader's Functionality

    To check the reader operability, put your palm to the palm vein scanner or a card of the corresponding format to the card reader (provided that the reader is connected to a powered BioSmart UniPass controller). A beep should sound, and the LED should display a successful or unsuccessful identification signal.
  • Page 19: Pv-Wm Reader Settings

    Table 7, it’s recommended to contact technical support. PV-WM Reader Settings After connecting the readers to the BioSmart UniPass controller and connecting the controller to the local network, it’s necessary to specify the readers serial numbers. These actions are performed in the controller's WEB interface.
  • Page 20: Procedure For Performing Product Application Tasks

     Password: bioroot. After successful authorization pass on the “Settings” tab and enter the serial numbers of the BioSmart PV-WM readers in the corresponding fields “Ethernet port 1” and “Ethernet port 2” (see Figure 14). The serial number of each reader is given in the passport and on the reader back cover.
  • Page 21 If the reader is powered from a separate 12V power supply (via the 12V and GND terminations), then disconnect the power supply. If the reader is powered from the BioSmart UniPass controller via PoE, then to turn off the reader, remove the Ethernet connector from the corresponding port on the reader or controller board.
  • Page 22 Ethernet connector from the port. The biometric access control system as a whole and the BioSmart PV-WM reader as its integral part are not intended for operation in extreme conditions. The customer should provide for redundant devices (systems, panic buttons, etc.) that control locks / turnstiles and other necessary equipment that will be used...
  • Page 23: Maintenance For Intended Usage

    40 to plus 50 С. ACS BioSmart should be stored and transported at a relative humidity of no more than 70%. Storage and transportation of devices in the immediate vicinity of sources of heat and open fire is not allowed to avoid overheating.
  • Page 24 Support support@biosmart-tech.com +420 246 097 126 Skype: BioSmart TechSupport +420 246 097 126 Konevova 2660/141, 130 00 Prague, Czech Republic www.biosmart-tech.com sale@biosmart-tech.com...