Quick Start Guide
ProCurve Secure Router dl 1xT1 + DSX-1 Module
J8452A
S
PECIFICATIONS
Operating
T1/FT1 Frame Relay, T1/FT1 PPP, T1/FT1 Multilink PPP,
Modes
T1/FT1 Multilink Frame Relay, T1/FT1 HDLC
T1/FT1
Supported Standards: AT&T TR 62411, AT&T TR 54016,
Interface
Bellcore TR 194, ANSI T1.403
Line Rate: 1.544 Mbps ±75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples of 56/64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB (long), 0 to 655 ft (short)
Connector: RJ-48C
DS0 Assignment: Programmable
DSX-1
Supported standards: DSX-1 per ANSI T1.102
Interface
Line Rate: 1.544 Mbps
DSX Receiver Input Range: -10 dBdsx to +6 dBdsx
Capacity: 1 to 24 DS0s
Line Codes: AMI, B8ZS
DSX-1 interface to PBX
Framing: D4 (SF) or ESF
Line Length: 0 to 655 ft and -7.5 dB
Connector: RJ-48C
Clock Source
Network, internal, and through
Diagnostics
Test Pattern Generation and Detection: QRSS, 511,
all ones, all zeros
Network loopbacks (local and remote); responds to both
inband and FDL loop codes (T1 interface only)
Alarm generation and detection
Network and user sets of performance data (15 minutes
and 24 hours)
Compliance
FCC Part 15 Class A, EN 55022 Class A
ACTA/FCC Part 68, IC CS-03, UL/CUL 60950, IEC 60950
Physical
Dimensions: 6.99 cm (2.75 in) W x 10.80 cm (4.25 in) D
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Relative Humidity: Up to 95 percent, noncondensing at
30°C (86°F)
Non-Operating Temperature: -20°C to 70°C (-4°F to 158°F)
Non-Operating Relative Humidity: Up to 95 percent,
noncondensing at 30°C (86°F)
Altitude: Up to 3.05 km (10,000 ft)
61195863L1-13D, May 2006
5990-8893
I
I
NSTALLATION
NSTRUCTIONS
For ProCurve Secure Router modules with outside plant
Warning
connections, ensure that all cables are removed from the
module before installing or removing it from the router
chassis.
1.
Remove power from the unit.
2.
Slide the ProCurve Secure Router dl 1xT1 + DSX-1 Module into the
option slot until the module is firmly seated against the chassis.
3.
Secure the screws at both edges of the module.
4.
Connect the cables to the associated device(s).
5.
Complete the installation of the base unit.
6.
Restore power to the unit.
For safety information for the routers and all modules, please
Note
refer to the safety and ESD precautions in the ProCurve
Secure Router Installation Guide included in your router
shipment.
T1 N
(RJ-48C) C
ETWORK
Pin
Name
1
R1
2
T1
3
—
4
R
5
T
6-8
—
DSX-1 N
ETWORK
Pin
Name
1
R
2
T
3
—
4
R1
5
T1
6-8
—
www.procurve.com
P
ONNECTION
INOUT
Description
Receive data from the network
Receive data from the network
Unused
Transmit data toward the network
Transmit data toward the network
Unused
(RJ-48C) C
P
ONNECTION
INOUT
Description
Transmit data toward the DTE
Transmit data toward the DTE
Unused
Receive data from the DTE
Receive data from the DTE
Unused