Quick Start Guide
ProCurve Secure Router dl 8xT1/E1 Wide Module
J8463A
S
PECIFICATIONS
Operating Modes
T1/FT1 Frame Relay, T1/FT1 PPP, E1/FE1 Frame Relay, E1/FE1 PPP
8xT1 Interfaces
Line Rate: 1.544 Mbps ±75 bps
Line Codes: AMI or B8ZS
Framing: D4 (SF) or ESF
Input Signal: 0 to -36 dB (DS1); Support for Nx64 on all T1 interfaces
(1 through 8)
Line Build-Out: 0, -7.5, -15, -22.5 dB
Connector: RJ-48C
8xE1 Interfaces
Line Rate: 2.048 Mbps ±50 PPM
Line Codes: AMI or HDB3
Framing: FAS/NFAS with optional CRC-4
Input Signal: 0 to -30 dB (DS1) on all E1 interfaces (1 through 8)
FE1 Line Rate: Channelized timeslot (in multiples of 56/64 kbps)
Connector: RJ-48C
Clock Source
Network, internal
Diagnostics
Network Loopbacks: Line, payload, remote
Test Pattern Generation and Detection: QRSS, 2
all ones, all zeros
Standards
FCC Part 15 Class A, EN 55022 Class A, EN 61000-3-2, EN 61000-3-3
ACIF S016, ETSI TBR 12/TBR 13, ACTA/FCC Part 68, IC CS-03
UL/CUL 60950, EN 60950, IEC 60950, AS/NZS 60950
ITU G.703, ITU-T G.704 (CRC-4), ITU-T G.823, ITU-T G.797
Physical
Dimensions: 14.29 cm (5.63 in) W x 21.91 cm (8.63 in) D
Operating Temperature: 0°C to 50°C (32°F to 122°F)
Relative Humidity: Up to 95 percent, noncondensing at 30°C (86°C)
Non-Operating Temperature: -20°C to 70°C (-4°F to 158°F)
Non-Operating Relative Humidity: Up to 95 percent, noncondensing at
30°C (86°F)
Altitude: Up to 3.05 km (10,000 ft)
61195843L1-13B, April 2005
I
NSTALLATION
1.
2.
3.
4.
5.
6.
7.
Note
T1/E1 N
15
20
- 1, 2
- 1, 511,
Pin
1
2
3
4
5
6-8
www.procurve.com
5991-2111
I
NSTRUCTIONS
Remove power from the unit.
The ProCurve Secure Router dl
8xT1/E1 Wide Module is shipped
with the T1/E1 mode switch
(located on the circuit board) set to
T1 (switch set to 1). If you require
E1 functionality, using your
thumbnail, slide the switch to the
ON position as shown in the bottom
figure to the right.
Slide the 8xT1/E1 wide module into the wide option slot until the module is firmly
positioned against the chassis.
Secure the screws at both edges of the module.
Connect the cables to the associated device(s).
Complete the installation of the base unit.
Restore power to the unit.
For safety information for the routers and all modules, please refer to the
safety and ESD precautions in the ProCurve Secure Router Installation
Guide included in your router shipment.
(RJ-48C) C
ETWORK
ONNECTION
Name
Description
R1
Receive data from the network
T1
Receive data from the network
—
Unused
R
Transmit data toward the network
T
Transmit data toward the network
—
Unused
Copyright 2005 Hewlett-Packard Development Company, LP
Switch Set to T1 Mode
Switch Set to E1 Mode