CLEANING
Before any operation, disconnect the appliance
from the electric grid. Don't use a steam
cleaner for the cleaning the hob.
It is advisable to clean the appliance when it is
cold.
Glass platform and enamelled part
The glass platform and all of the enamelled parts
must be washed with a sponge and soapy water or
with a light detergent.
Do not use abrasive or corrosive products.
Do not leave substances, such as lemon or tomato
juice, salt water, vinegar, coffee and milk on the
enamelled surfaces for a long time.
GB
TECHNICAL CARACTERISTIC TABLES
BURNERS
GAS
DESCRIPTION
G30
G31
1
RAPID
G20
G30
G31
2
SEMI-RAPID
G20
G30
G31
3
AUXILIARY
G20
G30
G31
4
ULTRA-RAPID
G20
Short title or reference methods of measurement and calculation used to establish compliance
with the above requirements.
The performance of each individual burner is calculated according to EN 30-2-1 + A1: 2003 + A2: 2005.
The total return of the cooking surface is calculated according to EU Regulation 66/2014 Par. 2.2.
The efficiency is calculated only for the burners with a nominal capacity exceeding 1.16 kW (EN 30-2-1 +
A1: 2003 + A2 :. 2005; Par 4.1)
Information relevant to the customer to minimize energy consumption during use.
Saving tips:
common use pots with flat base, Use pots with the correct format, Use pots with a lid, minimize the amount of fat
or liquid, when you start a hot liquid to reduce the setting.
INSTRUCTIONS FOR THE USER
NORMAL
NOMINAL
PRESSURE
RATE
mbar
g/h
30
218
37
214
20
30
120
37
118
20
30
73
37
72
20
30
255
37
250
20
Burners and racks
These parts can be removed to make cleaning
easier.
The burners must be washed with a sponge and
soapy water or with a light detergent, wiped well
and placed in their housing perfectly. Make sure
that the flame-dividing ducts are not clogged.
Check that the feeler of the safety valve and the
start-up electrode are always perfectly cleaned, so
as to ensure an optimum operation.
Gas taps
The possible lubrication of the taps must be carried
out by specialized personnel, exclusively.
In case of hardening or malfunctions in the gas
taps, apply to the Customer Service.
I N J E C T O R
TAPE BY-PASS
DIAMETER
L/h
1/100 mm
87
87
274
129
65
65
154
97
50
50
95
77
94
94
334
141
12
NOMINAL HEAT
DIAMETER
INPUT (W)
1/100 mm
MAX.
42
3000
42
3000
Reg.
3000
31
1650
31
1650
Reg.
1650
27
1000
27
1000
Reg.
1000
60
3500
60
3500
Reg.
3500
(EE
gas
)
burner
MIN.
(%) *
950
950
53.8
950
600
600
58
600
450
450
/
450
2100
2100
56.6
2100