OBSERVED FAULT
Heater ignites, but
flame-out control
shuts off heater after
a short period of
time.
Heater will not
ignite, but motor runs
for a short period of
time.
Motor does not start
when heater is
plugged in, fan
rotates slowly or
does not turn.
WARNING
POSSIBLE CAUSE
Wrong pump pressure
Dirty air output, air intake,
and lint filters
Dirty fuel filter
Dirt in nozzle
Dirty photocell lens
Bad flame-out control
Wrong pump pressure
Carbon deposits on spark
plug and/or improper gap
Dirty fuel filter
Dirt in nozzle
Water in fuel tank
WARNING: High voltage!
Electronic ignitor not
grounded (earthed)
Bad electronic ignitor
Flame-out control not reset
Binding pump rotor
REMEDY
See Pump Pressure
Adjustment, page 14.
See Air Output, Air Intake
and Lint Filters, page 14.
See Fuel Filter, page 11.
See Nozzle, pages 15 and
16.
Clean photocell lens.
Replace flame-out control.
See Pump Pressure
Adjustment, page 14.
See Spark Plug, pages 12
and 13.
See Fuel Filter, page 11.
See Nozzle, pages 15 and
16.
Drain and flush fuel tank
with clean kerosene.
See Storing, Transport-
ing, or Shipping, page 8.
Make sure electronic
ignitor mounting is tight.
Replace electronic
ignitor.
Reset flame-out control
button, see Figures 5 and
6, page 7.
If fan is hard to turn, see
Pump Rotor, page 17.
9