INDUSTRIAL FIXED GAS DETECTOR, FD-60 FORENSICS DETECTORS INDUSTRIAL FIXED GAS CONFIGURATION & COMPONENTS DETECTOR INCLUDED Serial #: Model: FD-60 Gas Sensor Remote Control USER MANUAL Hex Tool 24V Wall Adapter Detector Power Cable LED/Buzzer Fixture Calibration Cap QC/CAL Certificate User Manual...
Page 2
INDUSTRIAL FIXED GAS DETECTOR, FD-60 FORENSICS DETECTORS 1. INTRODUCTION The FORENSICS DETECTORS FD-60 FIXED GAS DETECTOR is the most advanced wall mount fixed gas detector available and adopts an advanced electrochemical gas sensor which can detect the gas concentration in the air to a digital readout signal output.
Key Recommendations • Monthly Calibration We recommend purchasing the necessary gas bottle to undertake bump testing and calibration. Recommended gas bottles are on our FORENSICS DETECTORS website or email us for a list to be sent to you. FORENSICS DETECTORS www.forensicsdetectors.com...
Page 5
INDUSTRIAL FIXED GAS DETECTOR, FD-60 FORENSICS DETECTORS 3. GAS SPECIFIC SPECIFICATIONS Detection 90% Response Minimum Alarm Set Point Range Accuracy Time Readout Low/High 0-2000ppm ±5%(F.S) ≤25s 0.01ppm 0.3/5ppm 0-30%vol ±5%(F.S) ≤15s 0.10% 19.5%/23.0% 0-100%LEL ±5%(F.S) ≤5s 1%LEL 25.0%/50.0%LEL 0-1000ppm ±5%(F.S) ≤25s...
INDUSTRIAL FIXED GAS DETECTOR, FD-60 FORENSICS DETECTORS 4. OPERATION SETUP: Unbox detector. Identify your power source. The detector comes with a power supply that connects to the power cord. To set up the detector remove the 5 hex screws with the hex driver provided.
INDUSTRIAL FIXED GAS DETECTOR, FD-60 FORENSICS DETECTORS 5. MENU DESCRIPTIONS 5.1 MAIN MENU Press OK on the remote control to enter the MAIN MENU. Click on “1.Back” to back to normal operational mode OR press back on the remote control.
INDUSTRIAL FIXED GAS DETECTOR, FD-60 FORENSICS DETECTORS 5.3. “ALARM SET” Menu Users can use this option to set the warning value and alarm mode. The detector is equipped with two alarm point settings. The alarm modes are LOW alarm and HIGH alarm values.
INDUSTRIAL FIXED GAS DETECTOR, FD-60 FORENSICS DETECTORS 5.7. Time Set The detector has a back-up battery, edit precise time to save. The detector will remain in accurate operation after the power is turned off. 6. INSTALLATION GUIDE 6.1 Installation Location Considerations Installing this industrial gas detector will depend on the application.
Page 10
INDUSTRIAL FIXED GAS DETECTOR, FD-60 FORENSICS DETECTORS ** WARNING** Ø KEEP DETECTOR AWAY FROM ELECTROMAGNETC & MAGNETIC INTERFERENCES (i.e. PHONES & MAGNETS) Ø STORE DETECTOR WITHIN SPECIFICATIONS Ø IF UNWELL, SEEK CLEAN AIR & MEDICAL HELP Ø ENSURE QUALIFIED PERSONNEL INSTALLS THE UNIT Ø...