ADC HiGain HLU-200 User Manual page 43

List 1d line unit for litespan-200 channel bank
Hide thumbs Also See for HiGain HLU-200:
Table of Contents

Advertisement

150-200-114-03, Issue 03
Type
Message
NONE
ALARMS:
RLOS
LOSW1(2) Loss of Sync Word 1
H1ES
H2ES
DS1
RAIS
MAL1
MAL2
CHREV
SMJK
LOOPBACKS:
(Doublers and
Non-Doublers)
NREM
NLOC
CLOC
CREM
TLOS
HLU-200 List 1D
Table 17. HLU-200 Status Menu Messages
Full Name
No Alarms
Remote Loss of Signal No signal from HRU-412 remote T1 interface.
HDSL loop 1 or 2 has lost sync.
or 2
HDSL Loop 1 Errored
Loop 1 CRC's have exceeded the user selected ES
Second
threshold.
HDSL Loop 2 Errored
Loop 2 CRC's have exceeded the user selected ES
Second
threshold.
Digital Service 1
DS1 input BPVs at the HRU-412 have exceeded the user
selected ES threshold.
Remote Alarm
Indicates an AIS (all 1s) pattern is being transmitted from
Indicating Signal
the remote or T1 output port.
Margin Alarm 1
The margin on HDSL loop 1 has dropped below the
threshold
(1 dB to 15 dB) set by the user.
Margin Alarm 2
The margin on HDSL loop 2 has dropped below the
threshold
(1 dB to 15 dB) set by the user.
Channels Reversed
The Loop 1 and 2 HDSL pairs are reversed at the
HRU-412 input port. Loop 1 is specified to carry the
(-) simplex DC voltage, and Loop 2 is specified to carry
the (+) simplex DC voltage.
SmartJack Loopback
Loopback at HRU-412 (remote) toward the CBA
initiated by either the (2 in 5) inband loopback code or
the out-of-band ESF data link code (Figure 7).
Network Remote
Loopback at HRU-412 (remote) toward the CBA
Loopback
initiated by upstream inband codes or from the
maintenance terminal (Figure 7).
Network Local
Loopback at HLU-200, (local) toward the CBA initiated
Loopback
by upstream inband codes or from the maintenance
terminal (Figure 7).
Customer Local
Loopback at HRU-412 (local) toward CI initiated from
Loopback
CPE (customer) by inband codes or from the
maintenance terminal (Figure 7).
Customer Remote
Loopback at HLU-200, (remote) toward customer
Loopback
initiated from CPE (customer) by inband codes or from
the maintenance terminal (Figure 7).
Transmit Loss of
HRU-412 is in a logic loopback state caused by a loss of
Signal (Loopback)
its T1 input from the CI, if enabled at the HRU-412,
List 6, 7 or List 8, via its TLOS switch option.
November 22, 1996
Description
Continued
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Slilns0a