Quick Links

Welding table (set value)
Process
1.0 mm
Material
Wire
Gas
S
U0
(m/min)
(V)
Fe
0.8
CO
2.5
19.0
2
Fe
1.0
CO
2.0
18.0
2
Fe
1.2
CO
1.0
18.0
2
Fe
0.8
ArCO
3.0
16.0
2
Fe
1.0
ArCO
2.0
15.0
2
Fe
1.2
ArCO
1.5
16.5
2
Fe
1.6
ArCO
2
CrNi
1.0
ArCO
3.0
15.0
2
CrNi
1.2
ArCO
2.0
15.0
2
AI
1.0
Ar
4.0
14.5
AI
1.2
Ar
3.5
13.0
Process
4.0 mm
Material
Wire
Gas
S
U0
(m/min)
(V)
Fe
0.8
CO
13.0
29.0
2
Fe
1.0
CO
6.0
22.5
2
Fe
1.2
CO
4.5
23.0
2
Fe
0.8
ArCO
14.0
26.0
2
Fe
1.0
ArCO
8.0
20.0
2
Fe
1.2
ArCO
5.5
20.5
2
Fe
1.6
ArCO
3.0
19.5
2
FeFlux
1.2
ArCO
6.0
21.0
2
CrNi
1.0
ArCO
9.0
25.0
2
CrNi
1.2
ArCO
8.0
24.0
2
AI
1.0
Ar
11.0
22.0
AI
1.2
Ar
10.0
18.0
1.5 mm
2.0 mm
3.0 mm
S
U0
S
U0
S
(m/min)
(V)
(m/min)
(V)
(m/min)
4.5
19.5
7.0
21.0
11.0
2.5
19.0
3.0
20.0
4.5
2.0
20.0
2.5
21.0
3.5
6.0
18.0
7.5
19.5
11.0
3.0
16.0
4.0
17.0
6.0
2.5
17.5
3.5
18.0
4.5
1.0
17.0
2.0
18.0
2.5
4.0
16.0
6.0
17.0
8.5
3.0
16.0
3.5
16.5
6.0
6.0
15.0
7.5
16.0
9.0
5.0
15.0
8.0
16.0
9.0
6.0 mm
10.0 mm
S
U0
S
U0
(m/min)
(V)
(m/min)
(V)
18.0
30.0
24.0
37.0
9.0
24.5
14.0
32.0
7.5
28.5
11.0
36.0
18.0
31.0
24.0
33.0
11.5
26.5
16.0
30.0
8.0
29.0
10.0
32.0
4.0
22.0
5.5
29.0
8.0
25.0
11.0
28.0
10.0
27.0
10.0
24.0
12.0
31.0
13.0
25.0
15.0
27.0
13.0
23.0
15.0
26.0
Table 1
Setting the welding process
Press and hold (11A) to open for setting the welding process. Choose parameter by turning (10).
Set the chosen value by turning (11). To close this function, press (11A) briefly.
Press (12) briefly to turn display of Fxx (F = function) parameter names on/off.
U0
(V)
27.0
MIG/MAG parameters
21.0
22.0
A
20.0
19.0
20.5
18.5
20.0
m/min
18.0
19.0
t1
S
17.0
GS.F / F22 (gas flow) 0,5-27 l/min (only machines with IGC) (optional equipment)
MMA (electrode) parameters
When the MMA welding program is chosen, the operator is
allowed access to the following parameters only
A
t
Set welding
current (A)
Figure 1
50113783 A
QUICKGUIDE
OMEGA³ YARD BASIC
Actual welding current (A)
Pr.G / F31
Pre-gas
S.St / F32
Soft start
bb.t / F37
Burn-Back
Po.G / F38 Post-gas
SP.t / F39
Spot time
t
t2
S
S
t
HS.A / F11 Hotstart
(25%)
HS.t / F12 Hotstart time
(0,5 sek.)
Arc / F13
Arc force
(25%)
Short circuit
t
UK
(0.2 sec.)
(1.0 m/min.)
(5 (0-30))
(3.0 sec.)
(0.0 sec.)

Advertisement

loading
Need help?

Need help?

Do you have a question about the OMEGA 3 YARD BASIC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Migatronic OMEGA 3 YARD BASIC

  • Page 1 QUICKGUIDE OMEGA³ YARD BASIC Welding table (set value) Setting the welding process Press and hold (11A) to open for setting the welding process. Choose parameter by turning (10). Process 1.0 mm 1.5 mm 2.0 mm 3.0 mm Set the chosen value by turning (11). To close this function, press (11A) briefly. Press (12) briefly to turn display of Fxx (F = function) parameter names on/off.
  • Page 2 QUICKGUIDE OMEGA³ YARD BASIC Fault indicator MMA welding See instruction manual Press the key to choose MMA welding. Long press recalls factory settings if indicator Display of wire feed speed or is on. welding current MIG/MAG welding Display of welding voltage or Press the key to choose MIG/MAG welding.