Pal Progressive Mode (50P); Ntsc Progressive Mode (60P) - Panasonic TX-51P800X Service Manual

Hide thumbs Also See for TX-51P800X:
Table of Contents

Advertisement

8.3.

PAL Progressive mode (50p)

8.3.1.
Preparation
1. Receive PAL monoscope pattern.
2. Copy the Data of PAL 100Hz mode (100i) to PAL
Progressive mode (50p)
3. Set scan mode to progressive.
4. Set the Picture Menu to NORMAL.
5. Set the TV to Service Mode 1.
6. Set the Data of Service Mode 1 as follow
H-Parallel
8
IVBL C
90
Top-Corner
173
7. Push [ 0 ] button so that set the Data of Coarse/Fine
Convergence to Zero Correction.
8. Push [ HELP ] button so that projecting Green only.
8.3.2.
V-Amp, V-Linear and V-Pos
Adjustment
1. Adjust Vertical amplitude for 2.3 ± 0.1 division of a scale by
V-Amp control.
2. Confirm Vertical Linear as to the balance of circle, if need
adjust V-Linear control.
3. Confirm Vertical Center, if it is not correct, adjust
Monoscope pattern for center of the screen by V-Pos
control.
Bottom-Corner
173
V-S-Correct
90
C-Correct
6
TX-51P800X / TX-51P800HM / TX-51P800HQ / TX-43P800X / TX-43P800HM / TX-43P800HQ / TX-43P800HZ
8.4.

NTSC Progressive mode (60p)

8.4.1.
Preparation
1. Receive NTSC monoscope pattern.
2. Set scan mode to Progressive.
3. Set the Picture Menu to NORMAL.
4. Set the TV to Service Mode 1.
5. Set the Data of Service Mode 1 as follow
H-Parallel
IVBL C
Top-Corner
6. Push [ 0 ] button so that set the Data of Coarse/Fine
Convergence to Zero Correction.
7. Push [ HELP ] button so that projecting Green only.
8.4.2.
H-Pos and H-Amp Adjustment
1. Adjust Monoscope pattern for center of the screen by H-
Pos control.
2. Adjust Horizontal amplitude for 2.3 ± 0.1 division of a scale
by H-Amp control.
25
8
Bottom-Corner
95
V-S-Correct
176
C-Correct
167
92
6

Advertisement

Table of Contents