Chapter 3. Operation
MENU ITEM
B1 REMOTE LPBK
B2 REMOTE LPBK
LOCAL LOOPBACK
B1 2047 PATT
B2 2047 PATT
INJECT ERROR
PATT RESULTS
B1 REMOTE
LPBK
B2 REMOTE
LPBK
LOCAL
LPBK
3-8
Dual U-BR1TE Plug-in Option Card User Manual
Table 3-2 identifes the available selections for P
PARAMETER CHOICES
ADDRESS 1, 2, 3, 4, 5, 6, NT1, NO LOOPBACK
ADDRESS 1, 2, 3, 4, 5, 6, NT1, NO LOOPBACK
B1, B2, NO LOOPBACK
T1_TX, LP_TX, NONE
T1_TX, LP_TX, NONE
Inserts error into transmitted pattern
Activates/deactivates the display of the test pat-
tern's errored seconds.
Remote loopbacks of the B1 channel in the network-to-
customer direction are initiated by selecting items under
this menu. The loopback may be requested for this unit
and the five next U-BR1TES toward the NT1. A LOOP-
ING message is displayed on the LCD once a test has
been initiated. The initiating U-BR1TE sends the loopback
command and begins transmitting the internally generat-
ed 2047 pattern. When the U-BR1TE begins receiving the
2047 pattern, it displays FAR END LOOPED on the LCD.
The initiating U-BR1TE transmits the 2047 pattern for the
duration of the test. The user can view the pattern results
by choosing menu item 7)PATT RESULTS, and can inject
errors into the transmitted pattern by choosing menu
item 6)INJECT ERROR. Select NO LOOPBACK under
the B1 REMOTE LPBK menu to exit the test.
The B2 REMOTE LPBK operates exactly like the B1 RE-
, but the B2 channel is looped back rath-
MOTE LPBK
TEST
er than the B1 channel.
The local U-BR1TE may be commanded to loop back ei-
ther the B1 or B2 channel. When a channel is put in L
, it will loop back both the T1 and U-interface
L
OOPBACK
data associated with the channel.
Table 3-2. P
T
ORT
EST
61200107L1#HS-1
.
T
ORT
EST
Parameters