Notice for safety.
Please give particular care to following signs.
ATTENTION: Before installing the pump please carefully read this manual. Guarantee will not be activated in case of improper
use.
CHAP.1 FEATURES
®
BIOX
range pumps are particularly suitable to remove dirty water with suspended solids.
®
BIOX
pumps are well sized and can be possibly utilized both in fixed or movable installations.
®
BIOX
pumps are used to transfer dirty water, waste water and sewage water.
Each pump is tested and packed very attentively.
Please ensure pump has not been damaged during transport; if this occurs please phone the dealer, within 8 days from
purchasing day.
CHAP. 2 USE AND HIS LIMITATIONS
MAX. TEMP.OF LIQUID: ....................................................................................
MAX. IMMERSION HEIGHT: ..............................................................................
MAX. FREE PASSAGE: ....................................................................................
MAX. ON/OFF CYCLES/HOUR: .......................................................................
4
INDEX
DANGER
Electric shock risk
DANGER
REMARK
REMARK
REMARK
Improper use may lead into electric shock.
Improper use may lead into heavy risk for
persons and things.
Improper use may cause damage to pump
or installation.
Pump cannot be used to move inflammable or
dangerous liquids.
Ensure pump never runs dry
50°C in continuous service to motor completely submerged.
7 m with 10 mt. of power cord
40 mm
30 equally spaced

Advertisement

loading

Summary of Contents for Nocchi BIOX 200/8

  • Page 1 INDEX Cap.1- Features Cap.2- Use and his limitations Cap.3- Installation Cap.4- Electric connections Cap.5- Maintenance and trouble shooting Notice for safety. Please give particular care to following signs. DANGER Improper use may lead into electric shock. Electric shock risk Improper use may lead into heavy risk for DANGER persons and things.
  • Page 2 Please refer to Fig. 1 The linear meausures in chart are in millimeters START LEVEL STOP LEVEL WEIGHT MIN. PRIMING MIN. DRAINAGE TYPE LEVEL LEVEL Picture 250mm BIOX® 200/8 123mm 45mm 370mm 300mm BIOX® 300/10 123mm 45mm 400mm 300mm BIOX® 400/12 123mm 45mm 400mm...
  • Page 3 Overload protection ® BIOX range pumps have a built-in thermal overload with automatic reset. Further protections are not required. ® BIOX range three phase pumps can be protected by using a magneto-thermic motor protector or a contactor with thermal relay; in both cases they have to be rated conforming to nominal power showed on motor plate.

This manual is also suitable for:

Biox 300/10Biox 400/12