1
Preparations
• Following items are required for testing. (Input impedance of measuring instrument is more than 1 MΩ.)
- Level meter (with JIS-C fi lter)
- Frequency counter: Below decimal point 3 or more fi gures measurement is possible.
- USB cable
- AC adaptor PA-300C
- Headphone
• Set each control as follows.
- MASTER VOLUME: Max
- PEDAL: OFF
Connect the stereo plug to only one terminal of the [PHONES] jack when taking measurements. (33 Ω load)
2
To enter Test Program
Turn on the power with [C#2], [F2] and [G#2] keys pressed and held simultaneously. (Fig. 1)
Once the Test Program is started properly, the sine wave of A3 sounds. The sound stops when a key is pressed.
3
To proceed the test
Test items are listed in Table 1.
Press the corresponding key to select and execute each test. (See Fig. 2)
To enter the test item select mode after completing each test item, press the [DEMO/SONG] button.
#
#
#
#
#
#
A
-1
C
0 D
0
F
0 G
0 A
0
C
A-1
B-1
C0 D0
E0 F0 G0 A0
B0 C1 D1
4
Test result
Each test result is indicated by the sound.
When the test result is OK, the sine wave of C4 sounds.
When the test result is NG, the sine wave of C2 sounds.
34
#
#
#
#
#
#
#
#
#
1 D
1
F
1 G
1 A
1
C
2 D
2
F
2 G
2 A
E1 F1 G1 A1
B1 C2 D2
E2 F2 G2 A2
#
#
C
2
F2
G
2
(Fig. 1)
#
#
#
#
#
#
#
#
2
C
3 D
3
F
3 G
3 A
3
C
4 D
4
F
B2 C3 D3
E3 F3 G3 A3
B3 C4 D4
E4 F4 G4 A4
2 4
7 9 11
14
16
1 3
5 6 8 10 12
13 15
17 18 20 22 24
Test No.
(Fig. 2)
#
#
#
#
#
#
#
#
#
4 G
4 A
4
C
5 D
5
F
5 G
5 A
5
C
6 D
B4 C5 D5
E5 F5 G5 A5
B5 C6 D6
19 21 23
26
25 27
#
#
#
#
6
F
6 G
6 A
6
E6 F6 G6 A6
B6 C7
28