Installation

Connecting the Cables

1. Remove the cover control from the unit by
loosening the 3 screws.
2. Dismount caps on the conduit panel.
3. Temporarily mount the conduit tubes on the
conduit panel.
4. Properly connect both the power supply and
low voltage lines to the corresponding
terminals on the terminal block.
5. Ground the unit in accordance with local
codes.
6. Be sure to size each wire allowing several
inches longer than the required length for
wiring.
7. Use lock nuts to secure the conduit tubes.
NOTICE
Connector trade size for this unit is
1/2"(12.7mm).
Refer to "How to connect wiring to the
terminals" for instructions on connecting
depending on the wire type you are using.
WARNING:
• Be sure to comply with local codes
while running the wire from the
indoor unit to the outdoor unit(size
of wire and wiring method, etc).
• Every wire must be connected
firmly.
• No wire should be allowed to touch
refrigerant tubing, the compressor
or any moving parts.
Power Supply
Power
Model
source
18K
1Ø, 208/230V 14
22 Room Air Conditioner
AWG(MIN)
Fuse or breaker
Capacity
18
20A
Wiring Diagram
Indoor Unit
Outdoor Unit
Terminal
Terminal
(4P)
(6P)
1
2
3
4
*
L1
L2
L1 is neutral for 115V models.
*
NOTICE
1.
shows field wiring.
2. Separately wire the high and low voltage line.
3. Use heat-proof electrical wiring capable of
withstanding temperatures up to 167°F(75°C).
4. Use outdoor and waterproof connection cable
rated more than 300V for the connection
between indoor and outdoor unit.
(For example, Type SJO-WA)
Outdoor unit
Terminal block
Over 5mm
(2")
Cover control
Connecting cable(Low voltage) b
1
2
Power supply a
3
4
5
6
To
G
branch
circuit
Ground
Conduit panel
Connecting
cable
Power supply
cord