Operation

• Unit start I stoe_
Remote controller
Remote controller
1. Unit start
Press ON/OFF on the remote
controller, unit starts.
2. Select operation mode
COOL : Refrigeration mode
HEAT : Heating mode
DRY : Dehumidification mode
FAN : Air supply mode
AUTO: Automatic mode
3.Select temp.setting
button
Press
Every time the button is pressed, temp.setting
increase 1
C,if kept depressed, it will increase
o
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes
as follows:
Remote controller:
LOW
MED
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to
room temperature.
Operation
Remote
Mode
Controller
Under the mode of auto operation, air conditioner will automatically
select Cool or Heat operation according to room temperature. When
AUTO
FAN is set to AUTO, the air conditioner automatically adjusts the fan
speed according to room temperature.
Cooling only unit do not have displays and functions related with
COOL
heating.
In DRY mode, when room temperature becomes lower than temp.
DRY
setting+2℃,unit will run intermittently at LOW speed regardless of
FAN setting.
In HEAT mode,warm air will blow out after a short period of the time
HEAT
due to cold-draft prevention function.
In
FAN
operation mode, the unit will not operate in
mode but only in
temp. setting is disabled.
FAN
When
is set to
FAN
speed according to room temperature
not available.
2
3
4
3
Display
circulated
HI
AUTO
Note
COOL
or
is not available in FAN mode.And
FAN mode, AUTO
the air conditioner automatically adjusts the fan
AUTO,
mode,
operation is
.
In FAN
SLEEP
• Air Flow Direction Adjustment
1. Up and down air flow direction
For each press of
remote controller displays as follows according to different
operation modes:
1
COOL/DRY/FAN:
AUTO:
HEAT:
2.Left and right air flow adjustment
For each press of
displays as follows :
remote controller:
Pos.1
Pos.2
Pos.5
Pos.6
Cautions:
• When adjusting the flap by hand, turn off the unit.
• When humidity is high, condensate water might
occur at air outlet if all vertical louvers are adjusted
to left or right.
• It is advisable not to keep horizontal flap at
downdard position for a long time in COOL or DRY
mode, otherwise, condensate water might occur.
When restart after remote turning off, the remote
controller will automatically return to the previous set
swing position.
• DRED Operation
Haier Peaksmart enabled air-conditioners have a Demand
Response Mode display on the indoor unit.
The display could be labelled d1, d2, d3 (wording may dif f e r
model to model ) .
These modes are described in more detail below:
Mode Display
Your air-conditioner will continue
to cool or heat during the peak
DRM3
d3
demand event. The energy
consumed by your ai
is capped to 75%
Your air-conditioner will continue
to cool or heat during the peak
DRM2
d2
demand event. The ene
consumed by your ai
is capped to 50%
You
air-conditioner is still turned
on and the fan will continue to
HEAT
DRM1
d1
operate Your compressor is
turned off and cool/hot air will no
longer be generated
button, air flow direction on
button, remote controller
Pos.3
Pos.4
(This function is unavailable on some models.)
Description
What to do
No action is required.
-conditione
gy
No action is
-conditioner
DRM1 mode is only activated during
eme
gency demand management
situations. This mode will automatically
the device wtthin 2 hours If your air-con is in
this mode for longer than 2 hours please
contact Energex on 13 12 53
equired.