Chimney Requirements - Hearth and Home Technologies Outdoor Lifestyles ODVILLA-36H Owner's Manual

Outdoor woodburning fireplace
Hide thumbs Also See for Outdoor Lifestyles ODVILLA-36H:
Table of Contents

Advertisement

E. Chimney Requirements
When planning your fireplace location, the chimney con-
struction and necessary clearances must be considered.
The fireplace system and chimney components have
been tested to provide flexibility in construction. The fol-
lowing figures are the minimum distances from the base
of the fireplace.
Minimum overall straight height is 6 ft 4 in. If the
fireplace is freestanding and a minimum of 10 ft from
a combustible structure. See Figure 6.1
• Chimney must extend 2 ft (.6 m) above any portion
of the roof within 10 ft (3 m) of the chimney. Refer to
Figure 8.7
Minimum height with offset/return
Maximum height
Maximum chimney length between an offset
and return
Maximum distance between chimney
stabilizers
Double offset/return minimum height
Maximum unsupported chimney length
between the offset and return
• Maximum unsupported chimney height above
the fireplace
Minimum overall straight height if fireplace is
freestanding
Minimum Straight Height
Note: A maximum of two pairs of offsets and returns may
be used.
The CAK4A is required for use in Canada
20
Outdoor Lifestyles by Hearth & Home Technologies Inc.• 4072-203 Rev A • 08/18
ft
m
14.5
4.42
90
27.43
20
6.1
35
10.67
24
7.32
6
1.83
35
10.67
6.4
1.95
14.5
4.42

Advertisement

Table of Contents
loading

Table of Contents