B. Clearances
WARNING! Risk of Fire!
ure 6.2. DO NOT pack required air spaces with insulation or other materials.
Figure 6.2
18
Outdoor Lifestyles by Hearth & Home Technologies Inc.• 4072-203 Rev A • 08/18
You must comply with all minimum air space clearances to combustibles as specified in Fig-
Storm Collar
Roof Flashing
(attic)
(insulation)
2 in. (51 mm) min.
Ceiling Firestop
48 in.
1219 mm
0 in.
to floor
Clearances to Combustible Materials
Shaded areas
represent
2 in. (51 mm) min.
air space clearance
required around pipe
Attic
Insulation
Shield
(ceiling)
Offset/Return (secured
with hanger straps)
(ceiling)
Must have 2 in. (51 mm)
minimum clearance
to header
0 in. to level
of standoffs
1/2 in. (13 mm) to back &
sides of appliance