5
Insert-cover alignment
The device combination of insert and cover carries out an automatic insert-cover alignment as
soon as a cover is placed on an insert and the mains voltage is switched on.
Case 1: Insert and cover are brand new
After the insert-cover alignment, the device combination is functional in a standard configura-
tion.
Case 2: Insert is brand new and cover was already in operation
After the insert-cover alignment, the device combination is functional in a standard configura-
tion.
Case 3: Insert was already in operation and cover is brand new
After the insert-cover alignment, the device combination is functional in a standard configura-
tion.
Case 4: Insert and cover were already in operation in combination
After the insert-cover alignment, the device combination is functional. The device combination
performs its function according to its last configuration.
Case 5: Insert and cover were already in operation separately from one another
After the insert-cover alignment, the device combination is not functional. The insert-cover align-
ment identifies this case as a swapping of the covers, for example after renovating a room. The
insert-cover alignment reports an error via the status LED.
This device combination becomes functional again after programming with the ETS, a
master reset or resetting to factory settings.
Case 6: Insert is not supported by the cover
The insert-cover alignment reports an error via the status LED if the cover has been placed on
an insert not supported by the cover. The device combination is not functional.

5.1 Error message

The error reported by the insert-cover alignment is indicated by the status LED for 60 seconds.
Within these 60 seconds, the status LED flashes 3 times in pulses.
After an error has been detected during insert-cover alignment, the new assignment of a device
combination of insert and cover is only possible via the ETS. The device combination remains
without function until a new ETS is commissioned.
The 60-second signalling of the error is restarted each time the button is actuated.
The 2-gang device variant indicates the error message via the left status LED.
A firmware update is also possible in the event of an error.
32403802
10867449
10.11.2021
6 / 12