Download Print this page
Elsema PentaTimer PCR43302240T Manual

Elsema PentaTimer PCR43302240T Manual

Two channels, 433mhz penta receiver with time clock functions

Advertisement

Quick Links

Two Channels, 433MHz Penta Receiver with Time Clock Functions
Features
Supply voltage 240VAC (also available in 110-120VAC
supply for international markets)
Din rail mountable case
Two optically isolated inputs for manual control
Time clock with automatic daylight saving control
Antenna diversity for robust link with extended range
Unlimited remotes can be programmed to the receiver
Compatible with PentaFOB® and PentaCODE® remotes
Momentary, latching and timer modes are user selectable
On-board diagnostic LED's to indicate correct power,
reception and relay activation
Applications
Automatic 24 hour time clock switching on and off
Automatically open and close gates with a time clock
Home automation i.e. garden lights, swimming pool control etc
Security lighting
.... and anywhere else you need a time clock or wireless signal to
activate a contact closure
Description
Powered by top-grade components and technologies, the
clock that can store 50 programs. It can be programmed to switch "on" and "off" each of its relays based on a
time clock, isolated inputs or with the PentaFOB®" and "PentaCODE® remote controls.
The time clock is powered by its own lithium battery and therefore does not lose the time and programs when
the receiver is disconnected from the supply.
With features such as 240VAC supply connection, receiver frequency hopping, unlimited remote storage, din
rail mountable case and automatic daylight saving adjustment, this receiver makes it easy to install wireless
switching functions with time clock controls.
Output Modes
Relay output modes on the receiver are user selectable. By default the mode is set to momentary.
Factory Default = Momentary
Momentary
- Output is "on" for as long as any of the inputs are held active.
Latching
- Output remains "on" until next input is activated.
Similar to switching "on" and "off" a light.
On Time
- Once activated, the relay remains "on" for the set time. Adjustable from 1 - 600sec.
Each relay can be adjusted independently.
Timer
- Each relay can be switched "on" and "off" based on real time clock.
Function
For example: Switch "on" lights at 8pm and "off" at 6am weekdays only.
PentaTimer Receiver
PentaTimer receiver has a built-in 24 hour 7 day time
ELSEMA
2 Channel, Penta Receiver with Time Clock
PCR43302240T

Advertisement

loading
Need help?

Need help?

Do you have a question about the PentaTimer PCR43302240T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elsema PentaTimer PCR43302240T

  • Page 1 ELSEMA 2 Channel, Penta Receiver with Time Clock PentaTimer Receiver Two Channels, 433MHz Penta Receiver with Time Clock Functions PCR43302240T Features Supply voltage 240VAC (also available in 110-120VAC supply for international markets) Din rail mountable case Two optically isolated inputs for manual control...
  • Page 2 2 Channel, Penta Receiver with Time Clock Customised Software Custom output modes can be programmed to do special functions. Call Elsema for more details. Relay Output Modes of PCR43302240T Each channel output has its own 2-way dipswitch and an ON time trimpot for mode selection.
  • Page 3 ELSEMA 2 Channel, Penta Receiver with Time Clock Products in the Range PCR43301RE PCR43302P PCR43302R PCR43302RE 1-Channel Receiver with 2-Channel Plug in type 2-Channel Receiver with 2-Channel Receiver with Relay Output. Enclosed Receiver with Open Relay Outputs Relay Outputs. Enclosed...
  • Page 4 ELSEMA 2 Channel, Penta Receiver with Time Clock Technical Data Supply Voltage 240 Volts AC Mains. (110-120VAC supply for international markets) Frequencies 433.100 to 434.700MHz Receiver Sensitivity Better than 0.316uV (-117dBm) Operating Temperature Range -5 to 50°C Receiver Memory Storage Unlimited Remotes Decoding System Encrypted 17 billion codes combinations or On board 12-way code switch Outputs 2 Change over relay outputs, rated at 16 Amps at 240VAC each.
  • Page 5 Remove 4-screws in the lid to set the 12-way dip switch and to connect a programming cable to the program socket. The program socket is used to connect the Elsema PentaFOB programmer to add, edit, delete remotes and to activate tools, special features and modes.
  • Page 6 ELSEMA 2 Channel, Penta Receiver with Time Clock PentaFOB® Programming Instructions Coding the PentaFOB® remotes and receivers can be done in 2 different ways. 1. Using the Receiver 2. Using another Remote Control Coding using the Receiver 1. Check that all switches are “OFF” on the receivers 12-way dip switch 2.
  • Page 7 ELSEMA 2 Channel, Penta Receiver with Time Clock PentaCODE Programming Instructions 12- Way Dip Switch Coding 1. Set a random code on the receiver dip switch by flicking the dip switches "On" or "Off". (DO NOT USE THE DEFAULT FACTORY SETTING FOR THE 12-WAY DIP SWITCH AS THIS IS A COMMON CODE) 2.