Installation
Connect the gas inlet to a gas bottle equipped
with a regulator. The gas inlet is an Oxygen
Adaptor (9/16-18 R.H).
Connect the data wiring (Male XLR-5
connector for DMX/RDM) if you are using a
DMX or RDM controller.
Connect the power cord 190-250 VAC, 50/60
Hz, 2815W.
Open the gas bottle (CO
grade, over 99% of purity), and set the
regulator pressure between 50 and 60 psi
(3.5 and 4.1 bar, or 350 and 410 kPa).
Fill the reservoir with MDG Neutral Fog
Fluid.
Power ON the MDG Me4.
Working with the keyboard (LOCAL Mode)
Verify the communication mode in the «INTERFACE
COMM. ». When the «AUTO» mode is activated, the MDG Me4 is then
controlled by DMX, only if there is a signal. If the DMX wire is unplugged, the
control remains local.
When the generator is manually switched to «UNIT ON» mode («CONTROLUNITON»), the program starts the heating
cycle for approximately 8 minutes («STATUSSTATE = % HEAT»).
When the temperature reaches operating level, the Automatic Purging System
(«STATUSSTATE = PURGE»).
After the first purging cycle is completed (1 min), the generator is ready to produce fog («STATUSSTATE = READY»).
To produce Fog, switch the generator to «FOG ON» mode («CONTROLFOGON»).
The MDG Me4 will start to produce fog right away.
Fog emission can be controlled by adjusting the working pressure of the internal reservoir («CONTROLPRESSURE»).
The MDG Me4 will produce fog as long as the control parameters are within specifications, the fog fluid reservoir filled and
the gas bottle pressurized.
If a critical problem occurs, the fog generator automatically shuts down, and displays an error message in the Status Menu.
The most common errors are (check the manual for more details):
ERROR = P. LOW
ERROR = P. HIGH
ERROR = HEATER
ERROR = PCB HIGH
MDG Me4
or N
industrial
2
2
XLR-5 DMX/ RDM Connector
Gas bottle is probably closed, empty or not connected. Check also the regulator pressure.
The input gas pressure is too high (Pressure between 50-60 psi / 3.5-4.1 bar / 350-410 kPa).
Check the AC voltage.
Move the generator to a colder location.
Quick Start
USB Connector
MAIN POWER Switch
CO
or N
Gas input
2
2
50-60 psi ( kPa)
190-250 VAC, 50/60 Hz
TM
(APS™) will be initiated
Fog output
Fog fluid reservoir
LCD
Keyboard
VAC Input
../..