The TEF 9980 status light may be installed in Zone 1,
2 or safe area. The Equipment shall not be installed
in Zone 0!
HANDLE WITH CARE! The TEF 9980 is an Ex d op
is signal light, with a glass dome. Whereas glass is
chosen for its lifelong transparency and chemical sta-
bility, it has its limitations when it comes to impact
strength.
High intensity light output.
Do not look directly into the light.
This may cause discomfort or serious
permanent damage to your eyes.
Note that changes made to the product and/or instal-
lation of components which do not conform to the
manufacturer's specification, may be a safety viola-
tion. The manufacturer will in no circumstance be
held responsible for such activity.
For your health and safety, always use safety gear
suited for the task. Be certain to follow codes, regula-
tions and/or specific procedures that are related to
the installation.
COPYRIGHT
©2016-2018 Stahl Tranberg AS
The information contained in this document re-
mains the sole property of Stahl Tranberg AS. No
part of this document may be copied or reproduced
in any form or by any means, and the information
contained within it is not to be communicated to a
third party, without the prior written consent of Stahl
Tranberg AS. The document, or any part of it, may
not be translated to any other language without the
written approval from Stahl Tranberg AS.
DISCLAIMER
Stahl Tranberg AS endeavors to ensure that all infor-
mation in this document is correct and fairly stated,
but does not accept liability for any errors or omis-
sions.
R. Stahl Tranberg AS
E
info@stahl-tranberg.com
Main office: Strandsvingen 6
Office Oslo: Luhrtoppen 2
TEF 9980 STATUS LIGHT,
MAIN LIGHT & REPEATER LIGHT
ZONE 1, ZONE 2 & SAFE AREA
TUM5721 REV. C 23.01.2020
|
stahl-tranberg.com
|
N-4032 Stavanger
|
Norway
| T
+47 51 57 89 00
|
N-1470 Lørenskog
|
Norway
| T
+47 24 08 44 10
LIGHTING
USER MANUAL
IMPORTANT
Read this instruction carefully before installing the
product
| F
+47 51 57 89 50

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TEF 9980 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tranberg TEF 9980

  • Page 1 Subject to change without prior notice TUM5721 REV. C 23.01.2020 SAFETY INSTRUCTIONS The TEF 9980 status light may be installed in Zone 1, 2 or safe area. The Equipment shall not be installed in Zone 0! HANDLE WITH CARE! The TEF 9980 is an Ex d op is signal light, with a glass dome.
  • Page 2 TEF 9980 STATUS LIGHT - INSTALLATION AND USER MANUAL Intentionally left blank Page 2...
  • Page 3: Table Of Contents

    TEF 9980 STATUS LIGHT - INSTALLATION AND USER MANUAL TABLE OF CONTENTSNTS: CONTENTS SPECIFIC CONDITIONS OF USE AREA OF USE NUMBERS AND LOCATION OF LIGHT UNITS TOOLS REQUIRED FOR INSTALLATION MECHANICAL INSTALLATION ELECTRICAL INSTALLATION FAILURE MODES MAINTENANCE PUTTING INTO SERVICE...
  • Page 4: Specific Conditions Of Use

    The flameproof joints are not intended to be repaired. DO NOT OPEN OR REPAIR! The TEF 9980 is sealed for life, and shall not be opened for repair or in- spections. Should a fault occur, contact the manufacturer. Do not try to open the equipment for repair or modifications.
  • Page 5: Numbers And Location Of Light Units

    “dim” mode. Note: The light units when in combination with Tranberg control system are automatically monitored. Of this reason, according to CAA Paper 2008/01, redundancy light units and components can be omitted.
  • Page 6: Tools Required For Installation

    TEF 9980 STATUS LIGHT - INSTALLATION AND USER MANUAL TOOLS REQUIRED FOR INSTALLATION The TEF9980 is ready for use, delivered with a flying lead. We recom- mend you to install the TEF9980 with 4 pcs. M10 stainless steel bolts. We therefore recommend a 17mm wrench or socket wrench for instal- lation.
  • Page 7: Electrical Installation

    TEF 9980 STATUS LIGHT - INSTALLATION AND USER MANUAL ELECTRICAL INSTALLATION The light units are supplied with flying lead cable, standard length 3 meters. The cable shall be terminated in an Ex approved junction box. Cables must be effectively clamped to prevent pulling or twist- ing.
  • Page 8 TEF 9980 STATUS LIGHT - INSTALLATION AND USER MANUAL WIRING One light connected to one control system output. +24V LAMP On/Stby Sync Alarm 7-N/C Note: Electrical connections PE-bar are the same for both main and repeater light. Two lights connected to one control system output.
  • Page 9 TEF 9980 STATUS LIGHT - INSTALLATION AND USER MANUAL • For best EMI performance, bond lamp to earth via a PE wire. Earthing Connect wire to M5 earth screw at lamp base. Keep wire as short The screen of the cable shall be earthed in the junction box in order as possible, maximum 80cm.
  • Page 10 TEF 9980 STATUS LIGHT - INSTALLATION AND USER MANUAL Cable dimensions Voltage drop in cables should be calculated to ensure that voltage at lamp is minimum 16V. Use a current consumption of 6.15A for main lamp and 0.41A for repeater light to calculate voltage drop.
  • Page 11: Failure Modes

    TEF 9980 STATUS LIGHT - INSTALLATION AND USER MANUAL FAILURE MODES The TEF9980 constantly monitors the condition of the light by meas- uring temperature, voltage and current. Failure is reported to control system as described below. See also section “Lamp connections”.
  • Page 12: Maintenance

    We therefore strongly recommend installation of the TEF9980 only together with Tranberg control systems. The safety of the product is not based on the control system. Testing of the light and control system after installation is recommended.
  • Page 13: Storage Preservation

    TEF 9980 STATUS LIGHT - INSTALLATION AND USER MANUAL STORAGE PRESERVATION The product should be stored in the original box, in a dry location and within the operational temperature range. DISPOSAL The TEF9980 shall be disposed of according to national regulations.
  • Page 14: Part No

    Junction Box for Single Lamp Connection + Connection to Next Lamp 1058 2589 Eye bolt for fixing of security wire 0000 5838 Note: Junction boxes supplied with stopping plugs and one cable gland for lamp cable. Cable glands for cables which are not supplied by Tranberg not included. Page 14...
  • Page 15 TEF 9980 STATUS LIGHT - INSTALLATION AND USER MANUAL STATUS LIGHT 9980 006 - Low Dome STATUS LIGHT 9980 000/ 9980 005 - High Dome Option: Eye bolt for fixing of security cable, part no. 5838. 000A111490 JUNCTION BOX 1058 2589...
  • Page 16: Technical Data

    TEF 9980 STATUS LIGHT - INSTALLATION AND USER MANUAL TECHNICAL DATA Ex Protection: Ex II 2 G Ex db op is IIB+H T5 Gb Area of Use: Hazardous areas Zone 1 or 2, EPL Gb and safe area Materials: Powder coated seawater resistant aluminum, tempered glass.

Table of Contents