第 3 章 附录
LCD下面一行显示的BMC消息
DIMM Area Temperature Upper
Non-Critical
DIMM Area Temperature Lower
Critical
DIMM Area Temperature Upper
Critical
Processor Thermal Control
Upper Non-Critical
Processor Thermal Control
Upper Critical
DUMP Request !
OS shutdown Alm
Power Supply1 Failure
detected
Power Supply2 Failure
detected
Power Supply1 AC Lost
Power Supply2 AC Lost
Processor Missing
Processor Thermal Trip
DIMM1 Uncorrectable Error
DIMM2 Uncorrectable Error
DIMM3 Uncorrectable Error
DIMM4 Uncorrectable Error
Processor Internal Error
Sensor Failure Detected.
SMI timeout
IPMI Watchdog timer timeout
(Power off)
Node Manager Firmware Image
execution Failed
Node Manager Firmware Flash
Erase Error
Node Manager Firmware Flash
Corrupted
Node Manager Firmware Flash
Corrupted
Node Manager Internal Error
原因
检测到温度异常。
按下了转储按钮。
发生了 OS 停止错误。
供电单元发生异常。
供电单元的 AC 输入异常。
未安装 CPU。
由于 CPU 温度异常强制关闭了电
源。
DIMM1 中发生了无法恢复的错误。
DIMM2 中发生了无法恢复的错误。
DIMM3 中发生了无法恢复的错误。
DIMM4 中发生了无法恢复的错误。
发生了一个内部 CPU 错误
(IERR)。
检测到传感器异常。
当伺服系统管理中断,检测出超时
异常。
发生 watchdog 定时器超时异常。
Node Manager 发生了了异常。
Express5800/T110g-S, R110g-1E, T110g-E 维护指南
推荐措施
风扇出现故障或者受到阻碍。请与销售
代理商联系。
等待收集内存转储数据直至完成。
记录显示的消息,等待收集内存转储数
据完成后,请与销售代理商联系。
确保插好了电源线。如问题仍解决不了
请与销售代理商联系。
请与销售代理商联系。
请与销售代理商联系。
关闭电源等待约 30 秒然后重启服务器。