Safety and Installation Instructions 
for Europe, Asia, Australia, Latin America and Africa 
This document applies to Maxeon PV Modules 
Contents of this manual are subject to change without notice.  
www.sunpower.maxeon.com/int/PVInstallGuideIEC 
Maxeon Solar Technologies, Ltd.  
www.sunpower.maxeon.com 
 
 
 
 
 
 
 
 
 
 
 
 
 
Languages: 
 
English 
French 
German 
Italian 
Japanese 
Spanish 
Polish 
 
 
 
 
 
 
 
 
Document 001‐15497 Rev X 
          P/N 100657 
           P/N 520728

Advertisement

loading
Need help?

Need help?

Do you have a question about the Sunpower E Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Maxeon Sunpower E Series

  • Page 1                     NEW REVISION: X         Safety and Installation Instructions    for Europe, Asia, Australia, Latin America and Africa    This document applies to Maxeon PV Modules    Languages:    English  French  German  Italian  Japanese  Spanish  Polish    Contents of this manual are subject to change without notice.     In case of inconsistencies or conflicts between the English version and any other versions of this manual (or  document), the English version shall prevail and take control in all respects.    For the latest Europe, Asia, Australia, Latin America and Africa please refer to  www.sunpower.maxeon.com/int/PVInstallGuideIEC ...
  • Page 2  Do  not  allow  the  connectors  to  come  in  contact  with  chemicals  only.  such as greases, oils and organic solvents which may cause stress    cracking.  1.3 Limited Warranty   Do not install or handle the modules when they are wet or during  Module  limited  warranties  are  described  in  the  Maxeon  warranty  periods of high wind.  document  obtainable  at  www.sunpower.maxeon.com.  Please  read   Do not block drain holes or allow water to pool in or near module  this document for more information.  frames  Warranties do not apply to any of the following; ...
  • Page 3 Module Mounting    should be determined by the applicable codes. We recommend a size  not less than 4mm . The insulation type should be appropriate for the  The  Maxeon  Limited  Warranty  for  PV  Modules  is  contingent  upon  type of installation method used and must meet SCII (Safety Class II)  modules  being  mounted  in  accordance  with  the  requirements  and  IEC  61730  requirements.  To  minimize  the  risk  from  indirect  described in this section.  lightning strikes (Voltage surges), the system should be designed to    avoid loops in the wiring. ...
  • Page 4 Warranty for these modules.  module  and  reduce  the  strength  of  the  frame,  therefore  are  not  No  Maxeon  module  should  be  mounted  at  a  site  where  it  may  be  allowed.  Using  mounting  Clamps  or  clips  with  additional  grounding  subject  to  direct  contact  with  salt  water,  or  other  aggressive ...
  • Page 5 MAXEON SOLAR TECHNOLOGIES, LTD.  Safety and Installation Instructions ‐ Document 001‐15497 Rev.X Maxeon  specified  or  Maxeon    supplied  mounting  systems.    Modules  mounted  with  strict  adherence  to  Maxeon   Figure 3: Mounting Configurations  documentation,  using  hardware  systems  supplied  by  or  specified by Maxeon.    Figure 2 and Table 1.1 below demonstrate the mounting locations and  Tables 1.2 and 1.3 give allowed load ratings (designed test value) for  Maxeon modules.  Figure 2: Mounting Zone locations for Maxeon modules   Configurations 1 and 2 show mounting with rail support, 3 and 4  show mounting without rail support. In “With Rail Support” the rails  For P‐Series, MAX3 96, 104, 112 cells and MAX6 66 cells:  becomes conventional or rails transverse while “Without Rail  Support” becomes end mounted in long or short side. In the case  when the glass deflects it would not deflect in the rails for additional  support. ...
  • Page 6 MAXEON SOLAR TECHNOLOGIES, LTD.  Safety and Installation Instructions ‐ Document 001‐15497 Rev.X Table 1.3: Mounting Zone Load Ratings for Racking system with rail  Figure 4: Mounting Zone Locations for Performance modules  support. Refer to Configuration 1 and 2 in Fig.3  Wind (up & down) /  For P3, P5 UPP and P6 (COM‐M, COM‐S, RES BLK)  Module Configuration  Snow (down)  (units in Pa) (***)  Module size  Frame type  B    C    (1&2&3&4) (1&2&3&4) G3 (Black &Silver) &  96 cells and P3 BLK  2400 / 5400  G4.1 & G4.2   2400 / 2400  104 cells (MAX2,  MAX3) and 112‐cells  G4.2  3600/5400  (MAX3)  P3 RES+  G4.3  1600/3600  1600/3600  128 cells and P19‐COM  G4 & G4.1 & G4.2  3600 / 5400  2400/ 3600  P3‐COM  G4.2 & G4.3  2000/2400  1600/2400 ...
  • Page 7 During storage, modules need to be protected from rain or any kinds  of liquids. Required storage temperature is between 10°C to 40°C in a  dry environment (humidity between 30 to 80%). Do not store modules  outdoor to avoid moisture and wet conditions.    Modules that feature antireflective coated glass are prone to visible  finger  print  marks  if  touched  on  the  front  glass  surface.  Maxeon  recommends handing modules with anti‐reflective glass with gloves  (no leather gloves) or limiting touching of the front surface.  Any finger  print  marks  resulting  from  installation  will  naturally  disappear  over  time or can be reduced by following the washing guidelines in Section  6.0  below.  Any  module  coverage  (colored  plastic  tarps  or  similar)  during installation can lead to permanent front glass discoloration and ...
  • Page 8 MAXEON SOLAR TECHNOLOGIES, LTD.  Safety and Installation Instructions ‐ Document 001‐15497 Rev.X Table 2: Module Frame Details   Platform  Module mounting and ground hole detail  Frame Profile  RESIDENTIAL G3 FRAME ONLY  96 CELL MODULE FRAME DETAIL  SIDE FRAME PROFILE  10.30 mm 46.08 mm 18.50 mm 2.20 mm Residential    32 mm Modules  END FRAME PROFILE  10.50 mm Method 1: Frame Hole 46.08 mm Locations 1.27 mm     22 mm FOR COMMERCIAL (SILVER FRAME) MODULES ONLY, INCLUDES STACKING PINS ...
  • Page 9 MAXEON SOLAR TECHNOLOGIES, LTD.  Safety and Installation Instructions ‐ Document 001‐15497 Rev.X   Platform  Module mounting and ground hole detail  Frame Profile  FOR P‐SERIES COMMERCIAL GEN 4.1 FRAME MODULES  SIDE FRAME PROFILE    2067 mm 46 mm 32mm   Commercial  Modules   END FRAME PROFILE  4X Ø 4.2mm 20X Ø 6.8mm 4X 5.0mm (W) x 15.0mm (L) Ground Holes Mounting Holes   24 mm SLOT  ...
  • Page 10 MAXEON SOLAR TECHNOLOGIES, LTD.  Safety and Installation Instructions ‐ Document 001‐15497 Rev.X Platform  Module mounting and ground hole detail  FOR P3 MODULES   P3 BLK (GEN 4.3)  P3 COM (GEN 4.2)  998 mm 998 mm 954 mm 954 mm Mounting Holes 4X Ø6.8mm Mounting Holes 12X Ø6.7mm 4X Ø4.2mm Ground Holes Mounting Holes 4X 5.0mm (W) 8X Ø6.8mm x 15.0mm (L) Residential/  SLOT Commercial ...
  • Page 11 MAXEON SOLAR TECHNOLOGIES, LTD.  Safety and Installation Instructions ‐ Document 001‐15497 Rev.X Platform  Module mounting and ground hole detail  Frame Profile  FOR P3 UPP GEN 4.3 ( Customized)  2066 mm SIDE FRAME PROFILE  2022 mm 274 mm Commercial  35 mm   Modules  END FRAME PROFILE  8X (14mmx9mm) 4X Ø4.2 mm 35 mm Mounting Holes   Ground Holes   FOR P5 UPP & P6 BIFACIAL GEN 4.3    SIDE FRAME PROFILE 2384 mm 1400 mm 1100 mm...
  • Page 12 MAXEON SOLAR TECHNOLOGIES, LTD.  Safety and Installation Instructions ‐ Document 001‐15497 Rev.X   Platform  Module mounting and ground hole detail  Frame Profile  FOR P3 RES+ (GEN 4.3)  SIDE FRAME PROFILE  1690 mm 1500 mm 1300 mm 1100 mm Residential    32 mm Modules  END FRAME PROFILE  4X Ø 4.2mm 8X Ø 6.8 mm Ground Holes   Moun ng Holes 24 mm   FOR 112c GEN 4.2 FRAME MODULES  ...
  • Page 13 MAXEON SOLAR TECHNOLOGIES, LTD.  Safety and Installation Instructions ‐ Document 001‐15497 Rev.X Platform  Module mounting and ground hole detail  Frame Profile  FOR MAX6 72‐CELL GEN 5.6 FRAME MODULES  2047 mm SIDE FRAME PROFILE  1983 mm 1653 mm 1423 mm 1200 mm 35 mm 400 mm 35 mm 32 mm   Commercial  END FRAME PROFILE  Modules  35 mm 96.50 mm 4X Ø 4.60mm 16X Ø 6.80 mm 4X Ø...