Mechanical And Electrical Installation; Internal Structure Diagram; Installation - Etec EKEC Series User Manual

Ac electric vehicle charging pile
Table of Contents

Advertisement

2 Mechanical and electrical installation

2.1 Internal structure drawing
Digital E Meter
Surge Arrester
Type2

2.2 Installation

A、Overall dimension and installation size
B、 Drill 4xø6 35mm counterbore holes on the wall with the size of the mounting holes, insert the expansion screw plastic tube,
and then screw in the M4x30 self-tapping screws from the internal mounting holes of the charging pile.
C、The power cord is connected to a type B leakage circuit breaker, the single-phase charging pile is connected to N and L, and
the three-phase charging pile is connected to N\L1\L2\L3,
The ground wire (PE wire) is connected to the yellow and green two-color terminals, the schematic diagram is as follows:
N
L
EKEC1-1
Recommended cable section:
Current value(A)
Wire area(mm
)
2
MCB
EKEC1
PE
N
L1
L2
L3
10
2.5
16/32A
RCCB(Type B)
Contactor
BLU(N/C)
GRE(CHG)
RED(ERR)
Current adjustment
PE
EKEC1-3
16
20
2.5
4
-05-
PLUG
EKEC4
32
6
PE
N
L