- Mark the appropriate center of each PV module on the
framework for inverter placement.
- Attach the Micro-Inverter using hardware accessories that are
suitable for the framework used in the PV System, i.e. screws
and sliding blocks.
- Ensure a minimum distance of 20 mm between the roof top
and the bottom of the inverter. In addition, a distance of 25
mm between the back of the PV module and the top of the
inverter should be complied with.
63-05-500102-1_Rev-01
3
2
- The inverters are connected using 16A 3-pin AC connection
cables and distribution blocks, with one input and three
outputs, to form a continuous AC power circuit.
- Make sure that the maximum number of inverters in a branch
is not exceeded. (see table)
- Any unused AC Connectors must be covered with an end
cap.
- A circuit breaker with a current rating of 16A and a
characteristic of type B. (see table)
QUICK MANUAL -INV315-50EU
This Quick Manual provides basic information for the installation of the
AEconversion Micro-Inverter. For detailed information, please refer to the
Installation Manual provided on our website (http://www.aeconversion.de/de/
downloads.html).
WARNING!
All electrical installations must be done by in compliance with local and national
electrical codes.
CE Mark
The CE mark documents that according to the label the inverter fulfills the
following essential requirements of relevant directives:
· Directive on the Electromagnetic Compatibility with the Directive 2014/30/EC
· Low Voltage Directive (Directive 2014/35/EC)
Accessories needed
1 - Mounting accessories for PV racking system
2 - Distribution block
- Cover for distribution block
- Connection cables
- PLC gateway
3 - PV-modules including male and female connector Amphenol H4
EU/50Hz/230V
Non-EU/50Hz/230V
Installations:
Installations:
16A Circuit Breaker
16A Circuit Breaker
Type of inverter
Max. number of inverters in one branch
INV315-50 EU
10
10
3
- Make a note of the serial numbers of each inverter and the
corresponding PV module. It will help you later to create an
overview of your PV system.
- Connect the PV module to the Micro-Inverter using the DC
Cabling.
- Switch in the circuit breaker to energize the AC line.
turn over

Advertisement

loading
Need help?

Need help?

Do you have a question about the INV315-50 and is the answer not in the manual?

Questions and answers

Summary of Contents for AE Conversion INV315-50

  • Page 1 16A Circuit Breaker Type of inverter Max. number of inverters in one branch INV315-50 EU - Mark the appropriate center of each PV module on the - The inverters are connected using 16A 3-pin AC connection - Make a note of the serial numbers of each inverter and the framework for inverter placement.
  • Page 2 Symbols used Intended use and liability This manual uses the following types of safety symbols that are to be The AEconversion micro inverter converts the power generated by noted for the installation and operation of the inverter. Some of these the PV modules from direct current into grid compliant alternating symbols are also included on the label, which is located on the top side of current and supplies it to the power grid.

This manual is also suitable for:

Inv315-50eu