AS M0022 Manual

Tester for diagnostics of starter solenoids

Advertisement

Quick Links

2021.12.27
M0022
MANUAL
TESTER FOR DIAGNOSTICS
OF STARTER SOLENOIDS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M0022 and is the answer not in the manual?

Questions and answers

Summary of Contents for AS M0022

  • Page 1 2021.12.27 M0022 MANUAL TESTER FOR DIAGNOSTICS OF STARTER SOLENOIDS...
  • Page 3: Table Of Contents

    Control elements............................Connecting terminals............................ 3.3 Device menu..............................3.3.1 Start screen..............................3.3.2 System parameters menu........................3.3.3 Solenoid parameters menu........................3.3.4 Test results..............................4. TAKING INTO USE......................................................... M0022 FIRMWARE UPDATE 6. OPERATIONAL SEQUENCE ..........................7. SAFETY REGULATIONS WHILE WORKING WITH M0022................
  • Page 4: Description

    English User Manual - M0022 1. DESCRIPTION M0022 tester is designed to check starter solenoids of 12 and 24 V, both separately and with the starter assembly. The tester allows you to measure the following parameters of the solenoid: - pull-in current (A)
  • Page 5: Specifications

    Touch screen is designed to control the functions of the tester. Encoder is designed to set the voltage applied to the solenoid windings during the test, navigate through the settings menu and the parameters of the solenoid, as well as adjust them.
  • Page 6: Connecting Terminals

    English User Manual - M0022 Power button is designed to switch on and switch of the voltage. 3.2 Connecting terminals Terminal “50” is connected to the terminal of the solenoid, where “+” control comes from the ignition switch. Terminal "31" is the negative terminal of the starter, its housing.
  • Page 7: System Parameters Menu

    "SYSTEM SETTINGS" - Button to enter the "system parameters" menu. “SOLENOID PARAMETERS” - Button to enter the “solenoid parameters” menu “APPLY LAST RESULTS” – setting the parameters of the tested solenoid as reference, to compare them with the results of the subsequent checks.
  • Page 8 The "PERFORM CALIBRATION" menu item is for entering the calibration menu of the power supply unit. Each M0022 is calibrated at the factory and recalibration is required only in case of repairing, or after long time using. While updating the tester...
  • Page 9: Solenoid Parameters Menu

    English User Manual - M0022 3.3.3 Solenoid parameters menu Pic. 4 SOLENOID PARAMETRS "NOMINAL PULL CURRENT" - Rated current of the pull in winding. The current of the tested solenoid will be compared with this current value. "NOMINAL HOLD CURRENT" - Rated current of the holding winding. The current of the tested solenoid will be compared with this current value.
  • Page 10: Test Results

    English User Manual - M0022 3.3.4 Test results Рic. 5 Test Results Output “TEST RESULT” displays the result of the PASSED / FAILED check of the solenoid, in accordance with the specified parameters in the “SOLENOID PARAMETERS” menu. “TEST VOLTAGE” displays the voltage applied during the test to the solenoid pull in and holding windings "DROPOUT"...
  • Page 11: Taking Into Use

    English User Manual - M0022 4. TAKING INTO USE Check the received set. It has to include: - M0022 device; - 3pin network power cable; - red power cable with a crocodile clip + measuring core for terminal “30” connecting;...
  • Page 12: Operational Sequence

    This diagram will help you connect the device correctly: Pic.6 Starter connecting and checking steps M0022 allows you to test the solenoid assembly with the starter directly on the car or a dismantled solenoid separately from the starter. The device is connected to the solenoid according to the marking described in the item 3.2. The test is carried out in the following manner: - Connect the device to the 220V network;...
  • Page 13: Safety Regulations While Working With M0022

    - Do not store or use the device in places with high temperature, humidity, danger of explosion or fire, strong magnetic field. As a result of exposure to dampness, the performance of the device may take a turn for the worse.
  • Page 15 Produced by 18 Biolohichna St. 61030 Kharkiv, Ukraine +38 (057) 728 0171 Technical Support: support@servicems.eu General Enquiries: sales@servicems.eu Skype: MSG Equipment servicems.eu...